Mikkel Rykær Kraglund

Mikkel Rykær Kraglund

Auto-generated profile, based on publicly available information

Mikkel Rykær Kraglund

Technical University of Denmark (DTU)

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 July 2019 in Energy & Environmental Science
Verified
Journal Article
Open access
PDF file
MKMikkel Rykær Kraglund
Mikkel Rykær Kraglund
MCMarcelo Carmo
Marcelo Carmo
GSGünter Schiller
Günter Schiller
SASyed Asif Ansar
Syed Asif Ansar
DADavid Aili
David Aili
Jens Oluf JensenJens Oluf Jensen
Jens Oluf Jensen
Energy efficient and cost efficient water electrolysis is essential for the large scale implementation of renewable energy. The two commercial low temperature electrolyzer technologies each suffer from serious drawbacks. The proton exchange membrane (PEM) electrolyzers remain expensive and depend strongly on the scarce metal iridium. The alkaline electrolyzers suffer from a large footprint due to low rate capability. Here we present an approach to make an alkaline electrolyzer perform like a PEM electrolyzer by means of an ion-solvating membrane. A long lasting effort to replace the state-of-the-art thick porous diaphragm by an anion exchange membrane has not proven successful. The ion-solvating membrane represents a third way. Demonstration cells based on KOH doped polybenzimidazole membranes and nickel based electrodes exhibited 1700 mA cm−2 at 1.8 V. This is far exceeding what has previously been achieved with membranes in alkaline environments without platinum group metal catalysts, and is comparable to state-of-the-art PEM electrolyzers.

1 September 2020 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
GZGuangling Zhao
Guangling Zhao
MKMikkel Rykær Kraglund
Mikkel Rykær Kraglund
HFHenrik Lund Frandsen
Henrik Lund Frandsen
AWAnders Christian Wulff
Anders Christian Wulff
SJSøren Højgaard Jensen
Søren Højgaard Jensen
CGChristopher R. Graves
Christopher R. Graves

1 January 2021 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
JBJörn Brauns
Jörn Brauns
JSJonas Schönebeck
Jonas Schönebeck
MKMikkel Rykær Kraglund
Mikkel Rykær Kraglund
DADavid Aili
David Aili
JHJaromir Hnat
Jaromir Hnat
Thomas TurekThomas Turek
Thomas Turek
The separator is a critical component for the performance of alkaline water electrolysis as it ensures the ionic contact between the electrodes and prevents the product gases from mixing. While the ionic conductivity of the separator affects the cell voltage, the permeability of the dissolved product gases influences the product gas impurity. Currently, diaphragms are used as separators, the pore system of which is filled with the electrolyte solution to enable the exchange of ions. The breakthrough of the gas phase can be prevented up to a specific differential pressure. A drawback of diaphragms is the requirement of a highly concentrated electrolyte solution to maintain a high ionic conductivity. The usage of anion-exchange membranes could solve this problem. However, the long-term stability of such materials remains unproven. This study compares two pre-commercial diaphragms, an anion-exchange membrane, and an ion-solvating membrane with the state-of-the-art diaphragm ZirfonTM Perl UTP 500. Besides physical characterization, the material samples were evaluated electrochemically to determine the ohmic resistance and the product gas impurities. The results show that the thinner diaphragm outperforms the reference material and that polymer membranes can compete with the performance of the reference material.

21 July 2016 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
MKMikkel Rykær Kraglund
Mikkel Rykær Kraglund
DADavid Aili
David Aili
KJKatja Jankova
Katja Jankova
ECErik Christensen
Erik Christensen
Qingfeng LiQingfeng Li
Qingfeng Li
Jens Oluf JensenJens Oluf Jensen
Jens Oluf Jensen
Membranes based on poly(2,2′-(m-phenylene)-5,5-bibenzimidazole) (m-PBI) can dissolve large amounts of aqueous KOH to give electrolyte systems with ion conductivity in a practically useful range. The conductivity of the membrane strongly depends on the concentration of the aqueous KOH phase, reaching about 10−1 S cm−1 or higher in 15–25 wt% KOH. Herein, m-PBI membranes are systematically characterized with respect to performance and short-term stability as electrolyte in a zero-gap alkaline water electrolyzer at different KOH concentrations. Using plain uncatalyzed nickel foam electrodes, the cell based on m-PBI outperforms the cell based on the commercially available state-of-the-art diaphragm and reaches a current density of 1500 mA cm−2 at 2.4 V in 20 wt% KOH at 80°C. The cell performance remained stable during two days of operation, though post analysis of the membrane using size exclusion chromatography and spectroscopy reveal evidence of oxidative degradation of the base polymer at KOH concentrations of 15 wt% and higher.

27 March 2023 in ACS Energy Letters
Verified
Journal Article
Open access
DADavid Aili
David Aili
MKMikkel Rykær Kraglund
Mikkel Rykær Kraglund
SRSinu C. Rajappan
Sinu C. Rajappan
DSDmytro Serhiichuk
Dmytro Serhiichuk
YXYifan Xia
Yifan Xia
Jens Oluf JensenJens Oluf Jensen
Jens Oluf Jensen

21 February 2017 in Journal of Materials Chemistry A
Verified
Journal Article
Closed access
PDF file
DADavid Aili
David Aili
AWAndrew G. Wright
Andrew G. Wright
MKMikkel Rykær Kraglund
Mikkel Rykær Kraglund
KJKatja Jankova
Katja Jankova
SHSteven Holdcroft
Steven Holdcroft
Jens Oluf JensenJens Oluf Jensen
Jens Oluf Jensen
Steric hindrance is employed as a design strategy of polybenzimidazoles for ion-solvating polymer electrolyte membrane alkaline water electrolysis.