Stefanie Donner

Stefanie Donner

Auto-generated profile, based on publicly available information

Stefanie Donner

Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20. 65189 Wiesbaden, Germany

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 February 2017 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Open access
PDF file
KKKarl Philipp Kutzner
Karl Philipp Kutzner
TFTobias Freitag
Tobias Freitag
SDStefanie Donner
Stefanie Donner
MKMark Predrag Kovacevic
Mark Predrag Kovacevic
RBRalf Bieger
Ralf Bieger
Introduction The principle of implanting a calcar-guided short stem consists of an individual alignment alongside the medial calcar providing the ability of reconstructing varus and valgus anatomy in a great variety. However, still, there are broad concerns about the safety of extensive varus and valgus positioning in regard to stability, bony alterations, and periprosthetic fractures. Materials and methods 216 total hip arthroplasties using a calcar-guided short stem (optimys, Mathys Ltd.) in 162 patients were included. Depending on postoperative CCD angle, hips were divided into five groups (A–E). Varus- and valgus tilt and axial subsidence were assessed by “Einzel-Bild-Roentgen-Analyse”(EBRA-FCA, femoral component analysis) over a 2-year follow-up. The incidence of stress-shielding and cortical hypertrophy as well as clinical outcome [Harris Hip Score (HHS)] were reported. Results Postoperative CCD angles ranged from 117.9° to 145.6° and mean postoperative CCD angles in group A–E were 123.3°, 128.0°, 132.4°, 137.5°, and 142.5°, respectively. After 2 years, the mean varus/valgus tilt was −0.16°, 0.37°, 0.48°, 0.01°, and 0.86°, respectively (p = 0.502). Axial subsidence after 2 years was 1.20, 1.02, 1.44, 1.50, and 2.62 mm, respectively (p = 0.043). No periprosthetic fractures occurred and none of the stems had to be revised. Rates of stress-shielding and cortical hypertrophy as well as HHS showed no significant difference between the groups. Conclusions Valgus alignment results in increased subsidence but does not affect the clinical outcome. There is no difference in stress shielding and cortical hypertrophy between the groups. The authors recommend long term monitoring of valgus aligned stems.

1 November 2020 in Journal of Orthopaedic Science
Verified
Journal Article
Open access
KKKarl Philipp Kutzner
Karl Philipp Kutzner
EREmanuel Ried
Emanuel Ried
SDStefanie Donner
Stefanie Donner
RBRalf Bieger
Ralf Bieger
JPJoachim Pfeil
Joachim Pfeil
TFTobias Freitag
Tobias Freitag
Short-term results of several short-stem designs have indicated early axial migration. Mid- and long-term results for most designs are lacking. The objective of this study was to evaluate the mid-term migration pattern of a calcar-guided short stem five years postoperative. Implant migration of 191 calcar-guided short stems was assessed by Ein-Bild-Roentgen-Analysis Femoral-Component- Analysis (EBRA-FCA) 5 years after surgery. Migration pattern of the whole group was analyzed and compared to the migration pattern of implants potentially being "at hazard" with a subsidence of more than 1.5 mm at 2 years postoperatively. Influence of preoperative Dorr types (A vs. B vs. C), age (70 years), gender (female vs. male), weight (90 kg), BMI (30) and uni-vs. bilateral procedures on mid-term migration pattern was analyzed. Additionally outcome of varus- and valgus stem alignment was assessed. Mean axial subsidence was 1.5 mm (SD 1.48 mm) at final follow-up. Two years after surgery 73 short stems were classified "at hazard". Of these stems, 69 cases showed secondary stabilisation in the following period, whereas 4 cases presented unstable with more than 1 mm of further subsidence. Stem revision was not required neither in the group of implants with early stabilisation nor the group with pronounced early onset migration. Male gender and heavy-weight patients had a significant higher risk for axial migration, as well as extensive valgus stem alignment, whereas for Dorr type B, compared to A, no statistical difference could be observed. In most cases, even in the group of stems being "at hazard", settling could be documented. While different Dorr types did not show a statistically significant impact on axial migration, particularly in male and heavy-weight patients the risk of continuous subsidence is increased. In those 4 cases with further migration, undersizing of the stem could be recognized. At present, clinical consequences are still uncertain.