1 November 2020 in Journal of Orthopaedic Science
Short-term results of several short-stem designs have indicated early axial migration. Mid- and long-term results for most designs are lacking. The objective of this study was to evaluate the mid-term migration pattern of a calcar-guided short stem five years postoperative. Implant migration of 191 calcar-guided short stems was assessed by Ein-Bild-Roentgen-Analysis Femoral-Component- Analysis (EBRA-FCA) 5 years after surgery. Migration pattern of the whole group was analyzed and compared to the migration pattern of implants potentially being "at hazard" with a subsidence of more than 1.5 mm at 2 years postoperatively. Influence of preoperative Dorr types (A vs. B vs. C), age (70 years), gender (female vs. male), weight (90 kg), BMI (30) and uni-vs. bilateral procedures on mid-term migration pattern was analyzed. Additionally outcome of varus- and valgus stem alignment was assessed. Mean axial subsidence was 1.5 mm (SD 1.48 mm) at final follow-up. Two years after surgery 73 short stems were classified "at hazard". Of these stems, 69 cases showed secondary stabilisation in the following period, whereas 4 cases presented unstable with more than 1 mm of further subsidence. Stem revision was not required neither in the group of implants with early stabilisation nor the group with pronounced early onset migration. Male gender and heavy-weight patients had a significant higher risk for axial migration, as well as extensive valgus stem alignment, whereas for Dorr type B, compared to A, no statistical difference could be observed. In most cases, even in the group of stems being "at hazard", settling could be documented. While different Dorr types did not show a statistically significant impact on axial migration, particularly in male and heavy-weight patients the risk of continuous subsidence is increased. In those 4 cases with further migration, undersizing of the stem could be recognized. At present, clinical consequences are still uncertain.
1 February 2018 in Clinical Biomechanics
Short-stem total hip arthroplasty (THA) potentially offers advantages compared to conventional THA, including sparing bone and soft tissue and being a facilitated and less traumatic implantation. However, the indication is limited to patients with sufficient bone quality. Cemented short-stem THA might provide an alternative to conventional cemented THA. To date, no cemented short stem is available on the market. In the present in vitro study, primary stability of a new cemented short stem was evaluated, comparing standard (undersized stem) versus line-to-line (same-sized stem) cementing techniques, using six pairs of human cadaver femurs. Primary stability, including reversible micromotion and irreversible migration, was assessed in a dynamic material-testing machine. Fracture load was tested and fracture pattern analyzed. Both cementation techniques (standard vs. line-to-line) displayed comparable results with respect to primary stability without any statistical differences (micromotion: 17.5 μm vs. 9.6 μm (p = 0.063); migration: 9.5 μm vs. 38.2 μm (p = 0.188)). Regarding fracture load, again, no difference was observed (3670 N vs. 3687 N (p = 0.063)). In all cases, proximal fractures of Vancouver type B3 occurred. The present in vitro study demonstrates that the line-to-line cementation technique, which is favourable regarding the philosophy of short stem THA, can be further pursued in the course of the development of a cemented short stem. Further investigations should address how well the cemented short stem compares to well-established cemented straight-stem designs.
8 April 2017 in European Journal of Orthopaedic Surgery & Traumatology