Lixia Zhao

Lixia Zhao

Auto-generated profile, based on publicly available information

Lixia Zhao

Institute of Modern Physics (IMP), Chinese Academy of Sciences (CAS), Lanzhou, 730000, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2022 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
JLJiaqi Lu
Jiaqi Lu
MLMingbang Lv
Mingbang Lv
WYWei You
Wei You
WFWentian Feng
Wentian Feng
JZJingjing Zhang
Jingjing Zhang
LMLizhen Ma
Lizhen Ma
High frequency and magnetic rigidity are the requirement of accelerators for scanning magnets. The scanning magnets for the SESRI (the Space Environment Simulation and Research Infrastructure) project are excited by triangular currents with a maximum repetition frequency of 200 Hz. It is inevitable to produce eddy currents inside the iron yoke, especially at the pole end. The temperature rise will be caused by eddy current loss, damaging the insulation layer in coils and adhesive resin in the core. To ensure the successful design and long working life for the scanning magnet, it is essential to optimize the eddy-current losses and temperature rise. This paper provides the optimization method for the scanning magnet, describes the analysis method of eddy-current loss induced temperature rise in detail, and then the distribution of the eddy current and temperature on the yoke is calculated by the software of OPERA-ELEKTRA/TR. Meanwhile, the temperatures at some critical points of the scanning magnet were measured. The computed results verified the feasibility of the electromagnetic-thermal coupling analysis method, which agreed well with the experimental data.

20 December 2023 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
MLMingbang Lyu
Mingbang Lyu
QYQing Gao Yao
Qing Gao Yao
JZJingjing Zhang
Jingjing Zhang
LZLixia Zhao
Lixia Zhao
JYJing Yang
Jing Yang
LMLizhen Ma
Lizhen Ma
Fe-based nanocrystalline materials is a typical soft-magnetic material with advantages such as high saturated magnetic flux, high resistivity and low magnetostriction coefficient. By utilizing a specialized winding process, the ultra-thin strip has been successfully applied for use in scanning magnetic cores. For static field, the simulated and tested integral magnetic field uniformity is consistent, and tested effective length is slightly shorter than simulated one. The static magnetic field can meet the needs of scanning magnets. For transient field, the new iron core has less magnetic field delay and distortion compared to silicon steel sheet iron. The simulated maximum magnetic field delay is reduced from 161 Gauss to 16 Gauss. The maximum magnetic field delay of silicon steel sheet iron under test is 87 Gauss, and the corresponding data of the new iron core is almost 0 Gauss. With the weakening of the magnetic field delay, the magnetic field distortion should also be suppressed. With the novel iron core, the magnetic field of the scanning magnet can be improved, thereby reducing the distance from the scanning magnet to the terminal. Rotating gantry is the focus of current research on proton and heavy ion therapy accelerator facilities. This novel iron core can facilitate a decrease in the rotating diameter and weight of the gantry, while enhancing the scanning accuracy. Moreover, the novel iron core can be exploited in scenarios where ferrite cores are “excess capacity”, but traditional silicon steel cores are “insufficient capacity”, such as for certain bump magnets used in synchrotrons.

1 October 2025 in Journal of Instrumentation
Verified
Journal Article
Open access
LZLixia Zhao
Lixia Zhao
QYQing Gao Yao
Qing Gao Yao
JYJing Yang
Jing Yang
MLMingbang Lv
Mingbang Lv
Xiang ZhangXiang Zhang
Xiang Zhang
JZJingjing Zhang
Jingjing Zhang
The 300MeV proton and heavy ion accelerator is a major radiation source for Space Environment Simulation and Research Infrastructure (SESRI). A high intensity ion linac, as the injection system of the accelerator, includes 27 magnets. There are 4 quadrupole magnets that have high gradient magnetic field and short magnetic length. The bore radius of the high gradient quadrupoles is 24 mm, which gives an equivalent pole tip field of 1.0 T with the magnetic field gradient of 42 T/m. The special material of Fe-Co-V soft magnetic alloy is used to achieve the high gradient magnetic field and improve excitation efficiency. For the design of the magnet, the cross section and end chamfer are used to improve the magnetic field distribution. The field analysis of magnet assembly errors shows these could affect the multipole components of the field. Assessment of the field quality is performed using the rotating-coil measurement system. The high gradient quadrupole magnet can meet the requirements.

1 May 2025 in Journal of Instrumentation
Verified
Journal Article
Closed access
LZLixia Zhao
Lixia Zhao
QYQing Gao Yao
Qing Gao Yao
MLMingbang Lv
Mingbang Lv
Xiang ZhangXiang Zhang
Xiang Zhang
JYJing Yang
Jing Yang
JZJingjing Zhang
Jingjing Zhang
Proton Radiation Effects Facility (PREF) is a new national research infrastructure under construction at Xinjiang Technical Institute of Physics and Chemistry in China. The facility consists of an ECRIS (Electron Cyclotron Resonance Ion Source), a linac injector, a compact synchrotron, and two experiment terminals. The synchrotron dipoles are essential components of the accelerator. The synchrotron dipole with a bending angle of 90 degree, and a deflection radius of 0.95 m is proposed to meet the need of compact accelerator. They will provide the field quality from the injection field of 0.2 T up to the maximum value of 1.2 T, with the maximum ramping rate of 3 T/s. The field simulation results and measurement results of the dipole are presented and discussed in detail.