20 December 2023 in IEEE Transactions on Applied Superconductivity
Fe-based nanocrystalline materials is a typical soft-magnetic material with advantages such as high saturated magnetic flux, high resistivity and low magnetostriction coefficient. By utilizing a specialized winding process, the ultra-thin strip has been successfully applied for use in scanning magnetic cores. For static field, the simulated and tested integral magnetic field uniformity is consistent, and tested effective length is slightly shorter than simulated one. The static magnetic field can meet the needs of scanning magnets. For transient field, the new iron core has less magnetic field delay and distortion compared to silicon steel sheet iron. The simulated maximum magnetic field delay is reduced from 161 Gauss to 16 Gauss. The maximum magnetic field delay of silicon steel sheet iron under test is 87 Gauss, and the corresponding data of the new iron core is almost 0 Gauss. With the weakening of the magnetic field delay, the magnetic field distortion should also be suppressed. With the novel iron core, the magnetic field of the scanning magnet can be improved, thereby reducing the distance from the scanning magnet to the terminal. Rotating gantry is the focus of current research on proton and heavy ion therapy accelerator facilities. This novel iron core can facilitate a decrease in the rotating diameter and weight of the gantry, while enhancing the scanning accuracy. Moreover, the novel iron core can be exploited in scenarios where ferrite cores are “excess capacity”, but traditional silicon steel cores are “insufficient capacity”, such as for certain bump magnets used in synchrotrons.
14 March 2024 in IEEE Transactions on Applied Superconductivity
HIAF (High Intensity heavy ion Accelerator Facility) is a new generation heavy ion accelerator under construction in China. The HFRS (FRagment Separator of HIAF) is a fragment separator and also a transfer-line between the Booster Ring and the Spectrometer ring. HFRS magnet system is composed of 11 superconducting dipoles and 13 sets of triplets. The dipole magnets adopt a super-ferric scheme. The requirement for the dipole magnets is a large acceptance at moderate fields, which can be fulfilled by super-ferric magnets with wide apertures. The magnetic field ranges from 0.2 T to 1.6 T with a bending radius of 15.7 m and a bending angle of 10°. A homogeneous dipole magnet field shape is required in the good field region of x ±160; y ±70 mm. This paper presents a detailed design and optimization of the magnet based on a multi-parametric model. The integral field homogeneity is optimized by an automatic chamfering algorithm. According to the installation conditions of the HIAF-HFRS, the magnet adopts a block processing and assembly method, which is manufactured and assembled by 14 blocks. The first set of the magnets has been completed and tested, and the test results are better than the design indicators.
27 January 2022 in IEEE Transactions on Applied Superconductivity
The electron cooling technology is applied in the spectrometer ring (SRing) to improve the luminosity of ion beam for the High Intensity heavy-ion Accelerator Facility (HIAF). The electron cooler consists of a gun section, two 90-degree toroids, a cooling section and a collector section. There are four kinds of main coils used to provide longitudinal magnetic fields along the path of the electron beam. In this paper, we present the modeling and analyzing of the electron cooler magnets by three-dimension software. The optimizing of the magnetic field of cooling section is completed to achieve the required effective cooling length. The magnetic fields along the electron beam path and ion beam path are calculated and the beam trajectory of typical ion is also simulated to offer data for correcting the orbit.
23 February 2024 in IEEE Transactions on Applied Superconductivity
The Space Environment Simulation and Research Infrastructure (SESRI), located at the Harbin Institute of Technology (HIT) in China, is a new infrastructure project proposed by the Institute of Modern Physics, Chinese Academy of Sciences (IMP, CAS), and completed in 2022. As a critical part of SESRI, the compact synchrotron was designed with a circumference of less than 44 m and compact magnets. In order to achieve compact injection and improve injection efficiency, four fast-ramping bump magnets based on ferrite yokes were used. All four bump magnets have a fast falling time from 20–100 µs, a maximum magnetic field of 0.0797 T, and a gap of 60 mm. To reduce the magnetic eddy current effect and coil inductance during fast excitation, ferrite core structures with single copper bar saddle windings are used. Further, window-frame structures are used to facilitate the ferrite-core machining process. After the prototype bump magnet was fabricated and the pulsed magnetic field measured, it was found that the integrated magnetic field curve did not align with the output current curve of the power supply. This was found to be caused by eddy currents from the copper gaskets between ferrite cores. Through the simulation and secondary testing of the gasket-induced eddy currents using different materials, the eddy current has been significantly reduced. In this study, the magnetic field optimization, structural design, eddy current calculation, and magnetic field measurement of the fast-ramping bump magnets are analyzed.
1 October 2025 in Journal of Instrumentation
The 300MeV proton and heavy ion accelerator is a major radiation source for Space Environment Simulation and Research Infrastructure (SESRI). A high intensity ion linac, as the injection system of the accelerator, includes 27 magnets. There are 4 quadrupole magnets that have high gradient magnetic field and short magnetic length. The bore radius of the high gradient quadrupoles is 24 mm, which gives an equivalent pole tip field of 1.0 T with the magnetic field gradient of 42 T/m. The special material of Fe-Co-V soft magnetic alloy is used to achieve the high gradient magnetic field and improve excitation efficiency. For the design of the magnet, the cross section and end chamfer are used to improve the magnetic field distribution. The field analysis of magnet assembly errors shows these could affect the multipole components of the field. Assessment of the field quality is performed using the rotating-coil measurement system. The high gradient quadrupole magnet can meet the requirements.
1 May 2025 in Journal of Instrumentation
Proton Radiation Effects Facility (PREF) is a new national research infrastructure under construction at Xinjiang Technical Institute of Physics and Chemistry in China. The facility consists of an ECRIS (Electron Cyclotron Resonance Ion Source), a linac injector, a compact synchrotron, and two experiment terminals. The synchrotron dipoles are essential components of the accelerator. The synchrotron dipole with a bending angle of 90 degree, and a deflection radius of 0.95 m is proposed to meet the need of compact accelerator. They will provide the field quality from the injection field of 0.2 T up to the maximum value of 1.2 T, with the maximum ramping rate of 3 T/s. The field simulation results and measurement results of the dipole are presented and discussed in detail.