Chenglin Lyu

Mr. Chenglin Lyu

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2023 in Actuators
Verified
Journal Article
Open access
PDF file
CLChenglin Lyu
Chenglin Lyu
PMPedro Truppel Morim
Pedro Truppel Morim
BPBernhard Penzlin
Bernhard Penzlin
FRFelix Röhren
Felix Röhren
LBLukas Bergmann
Lukas Bergmann
CNChuong Ngo
Chuong Ngo
Rehabilitation of paralysis caused by a stroke or a spinal cord injury remains a complex and time-consuming task. This work proposes a hybrid exoskeleton approach combining a traditional exoskeleton and functional electrical stimulation (FES) as a promising method in rehabilitation. However, hybrid exoskeletons with a closed-loop FES control strategy are functionally challenging to achieve and have not been reported often. Therefore, this study aimed to investigate a powered lower-limb exoskeleton with a closed-loop FES control for Sit-to-Stand (STS) movements. A body motion capture system was applied to record precise hip and knee trajectories of references for establishing the human model. A closed-loop control strategy with allocation factors is proposed featuring a two-layer cascaded proportional–integral–derivative (PID) controller for both FES and exoskeleton control. Experiments were performed on two participants to examine the feasibility of the hybrid exoskeleton and the closed-loop FES control. Both open- and closed-loop FES control showed the desired performance with a relatively low root-mean-squared error (max 1.3∘ in open-loop and max 4.1∘ in closed-loop) in hip and knee trajectories. Notably, the closed-loop FES control strategy can achieve the same performance with nearly 60% of the electrical power input compared to the open-loop control, which reduced muscle fatigue and improved robustness during the training. This study provides novel insights into body motion capture application and proposes a closed-loop FES control for hybrid exoskeletons.

1 September 2022 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
CLChenglin Lyu
Chenglin Lyu
BHBennet Holst
Bennet Holst
FRFelix Röhren
Felix Röhren
BPBernhard Penzlin
Bernhard Penzlin
Steffen LeonhardtSteffen Leonhardt
Steffen Leonhardt
CNChuong Ngo
Chuong Ngo
Walking gait correction is fundamental to restoring body motion function for patients. Functional Electrical Stimulation (FES) is regarded as a promising method and essential to Neurotherapy, and the exoskeleton is fast becoming a key instrument in rehabilitation. Applying FES or exoskeleton alone, however, has its inherent disadvantages. Therefore, the hybrid exoskeleton combined with FES promoted in recent years overcomes the deficiency of more degree of freedom control. In this paper, a hybrid FES-Exoskeleton for walking gait control was first proposed and evaluated. With the Force Sensing Resistors (FSR) sensor, the exoskeleton actively assists in walking. Simultaneously, it also triggers the FES of the soleus, tibialis anterior, and gastrocnemius muscles for dorsilflexion and plantar flexion. Later, three different control strategies are employed for the pulse-width controlled FES. Eventually, an ILC with a PID controller is applied in the hybrid exoskeleton, following the best foot angle trajectory.

3 February 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SSShubhanshu Sharma
Shubhanshu Sharma
BGBoby George
Boby George
CLChenglin Lyu
Chenglin Lyu
PPPhilip von Platen
Philip von Platen
MLMarkus Lüken
Markus Lüken
Steffen LeonhardtSteffen Leonhardt
Steffen Leonhardt
The type of walking pathway influences gait. Thus a wearable gait sensing technique is important for continuous gait analysis. However, most of the wearable sensing technologies employed in gait analysis solely provide data on gait parameters and do not have mechanisms to sense and account for the type of pathways. In this paper, a novel technique is developed to simultaneously identify some of the spatiotemporal gait parameters and the type of pathway on which the subject is walking. This is achieved by measuring the electrical impedance of the floor between the shoes employing a measurement system reported recently. This paper shows that gait parameters can be derived using the impedance values measured between the shoes. These impedance values change as the legs move, primarily due to changes in capacitance between the shoe and the pathway. A suitable algorithm is developed and tested to estimate the gait parameters and walking speed from the developed prototype, and this is compared with the parameters obtained from reference force plate-based sensing. The testing is done on seven human subjects. The average root mean square error values for different gait parameters were found to be 0.02 s, 1.4 cm, 2.6 cm, 0.07 s, 0.8 steps/min, 2.24 % and 2.24 %, for stride time, stride length, step length, step time, cadence, stance phase, swing phase, respectively and a worst-case error of ±5 % in walking speed is observed. Further, the human subjects walked on different pedestrian pathways. Different features were extracted from the impedance waveform, which helped in successfully classifying all the six types of pathways we tested.

1 September 2021 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Open access
BPBernhard Penzlin
Bernhard Penzlin
CLChenglin Lyu
Chenglin Lyu
LBLukas Bergmann
Lukas Bergmann
CBCarl-Friedrich Benner
Carl-Friedrich Benner
YLYinbo Li
Yinbo Li
CNChuong Ngo
Chuong Ngo
Article 05-1700-P3 was published on September 1, 2021 in the journal Biomedical Engineering / Biomedizinische Technik (volume 66, issue s1).