29 September 2025 in International Journal of Mechanical Sciences
1 April 2013 in Ultrasonics
1 September 2016 in Ultrasonics
11 April 2017 in Measurement Science and Technology
This paper is intended to estimate the spatial averaging effects of the hydrophone in field characterization of focused transducers. The analytical model derived was based on Fresnel approximation and enabled modifications of the results for both on-axis and off-axis measurement arrangements. The axial and lateral field distributions in the focal plane measured by the hydrophone were derived for both non-attenuating and attenuating fluids in the model. The spatial averaging effects result in underestimating the absolute acoustic pressure amplitudes, and overestimating the cross-sectional size of the beam directivity pattern in the focal plane. The validity of the Rayleigh integral and the Fresnel approximation for curved transducers were discussed. The results indicate that, for (where k is the circular wave number, a h is the chord from the center of curved surface to the boundary and b is the effective radius of the hydrophone), the Fresnel approximation remains valid for all locations of the hydrophone in the focused field. Particularly, in the focal plane, the spatial averaging effects of the hydrophone on the directivity pattern of the acoustic beam can be neglected for (where a and l f are the effective radius and focal distance of the focused transducer).
14 April 2026 in Optics Express
High-intensity focused ultrasound (HIFU) has emerged as a promising noninvasive technology for medical applications, including tumor ablation and targeted drug delivery, where precise control of acoustic pressure is critical. However, the traceable sound pressure amplitude, in the range of several megapascals, is much lower than the actual application of 100 megapascals, which compromises the metrological traceability and impedes clinical translation. In this study, we present a differential high-bandwidth homodyne laser interferometer designed for the accurate realization of HIFU acoustic pressure under treatment conditions. The system employs a four-channel detection scheme and a focused measurement beam to enhance its robustness against pellicle deflection and environmental disturbances. By integrating high-speed photodetection and a nonlinear error suppression algorithm based on arctangent demodulation, the system achieved a bandwidth of 500 MHz while maintaining high sensitivity. The experimental results demonstrated the successful measurement of HIFU pressures up to 124 MPa peak-to-peak, with a resolution better than 0.25 MPa. Comparative studies using a commercial heterodyne vibrometer (UHF-120) confirmed the accuracy and cost-effectiveness of the proposed homodyne system. This study provides a reliable and traceable method for high-pressure ultrasonic metrology, supporting the development and safety assurance of HIFU-based therapies.