Homodyne laser vibrometer plays an essential role in the precision vibration measurement, but its application is restricted when measuring subfringe vibration and targets with various reflectivities. In order to achieve the nanoscale vibration measurement and to adapt to various reflectivities, an enhanced homodyne laser vibrometer is presented in this paper. First, an active vibration mechanism (AVM) based on a flexure hinge stimulated by a piezoelectric transducer (PZT) is introduced into the reference arm, with which the parameters for nonlinear error correction can be predetermined, and thereby the measurement of vibration less than quarter wavelength is feasible. Second, an automatic gain module is employed to optimize the intensity of the interference signals, which significantly improves the adaptability to target reflectivity. The experimental results show that the laser vibrometer proposed is capable of measuring vibration with amplitude down to 2 nm and vibration with surface reflectivity down to 0.08%.
As a high-end medical technology, high-intensity focused ultrasound (HIFU) is widely used in cancer treatment and ultrasonic lithotripsy technology. The acoustic output level and safety of ultrasound treatments are closely related to the accuracy of sound pressure measurements. Heterodyne laser interferometry is applied to the measurement of ultrasonic pressure owing to its characteristics of non-contact, high precision, and traceability. However, the upper limit of sound pressure measurement is limited by the bandwidth of the interferometer. In this paper, a high-bandwidth heterodyne laser interferometer for the measurement of high-intensity focused ultrasound pressure is developed and tested. The optical carrier with a frequency shift of 358 MHz is realized by means of an acousto-optic modulator. The selected electrical devices ensure that the electrical bandwidth can reach 1.5 GHz. The laser source adopts an iodine frequency-stabilized semiconductor laser with high-frequency spectral purity, which can reduce the influence of spectral purity on the bandwidth to a negligible level. The interference light path is integrated and encapsulated to improve the stability in use. An HIFU sound pressure measurement experiment is carried out, and the upper limit of the sound pressure measurement is obviously improved.
Laser heterodyne interferometry plays a crucial role in measuring the velocity of water particles during the calibration of hydrophones with the optical method. The velocity of water particles acts as an indicator of acoustic-pressure variations and can be used to evaluate the stability of the acoustic field. The calibration of hydrophones requires a stable acoustic field environment; currently, though, the assessment of acoustic field stability is largely subjective. This study introduces the Normalized Dynamic Time-Warping (NDTW) algorithm, which objectively evaluates acoustic field stability. Sine-fitting is applied to the region of interest in the measured signal to obtain a reference signal. Subsequently, the NDTW algorithm is used to calculate the difference between the measured and reference signals, enabling the assessment of acoustic field stability. The NDTW algorithm effectively identifies subtle differences between signals and addresses the accumulation errors arising from varying signal lengths. The calibration results showed that for signals of high quality within the identified frequency band, the calibration outcomes obtained using the NDTW algorithm deviated from the reciprocity method by no more than 0.7 dB. For frequency bands with poor signal quality identified by the NDTW algorithm, the deviation between the calibration results and the reciprocity method exceeded 0.7 dB.
High-frequency focused ultrasonic technology offers distinct advantages in microstructural inspection and high-resolution imaging owing to its short wavelength and superior acoustic field-focusing capability. Accurate determination of focused acoustic field characteristics is essential for reliable defect evaluation and image quality. This study proposes a precise method for calibrating the effective radius of high-frequency focusing ultrasonic transducer and −6 dB beamwidth of its acoustic field – two key parameters that directly affect the spatial resolution and focusing accuracy. A theoretical acoustic field model was established based on the Rayleigh integral, and the computational efficiency was enhanced using the Fresnel approximation. A hydrophone-based experiment was designed: the iterative method was employed to invert the geometric focal length and effective radius by analyzing the extrema (maximum and minimum values) of the on-axis acoustic pressure distribution, while the −6 dB beamwidth was determined by incorporating a spatial averaging correction into the analysis of the focal plane pressure profile. The experimental results demonstrate that the determined beamwidths agree with the measured values to within 3% across a frequency range of up to 100 MHz, thereby confirming the accuracy, robustness and practical applicability of the proposed calibration approach.