Sylvain Rivet

Sylvain Rivet

Auto-generated profile, based on publicly available information

Sylvain Rivet

Univ. de Bretagne Occidentale (France)

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2007 in Optics Express
Verified
Journal Article
Closed access
PDF file
MDMatthieu Dubreuil
Matthieu Dubreuil
SRSylvain Rivet
Sylvain Rivet
BJBernard Le Jeune
Bernard Le Jeune
JCJack Cariou
Jack Cariou
We present a new, to the best of our knowledge, experimental configuration of Mueller matrix polarimeter based on wavelength polarization coding. This is a compact and fast technique to study polarization phenomena. Our theoretical approach, the necessity to correct systematic errors and our experimental results are presented. The feasibility of the technique is tested on vacuum and on a linear polarizer.

4 February 2016 in Optics Express
Verified
Journal Article
Open access
PDF file
SRSylvain Rivet
Sylvain Rivet
MMMichael Maria
Michael Maria
ABAdrian Bradu
Adrian Bradu
TFThomas Feuchter
Thomas Feuchter
LLLasse Leick
Lasse Leick
Adrian PodoleanuAdrian Podoleanu
Adrian Podoleanu
A general theoretical model is developed to improve the novel Spectral Domain Interferometry method denoted as Master/Slave (MS) Interferometry. In this model, two functions, g and h are introduced to describe the modulation chirp of the channeled spectrum signal due to nonlinearities in the decoding process from wavenumber to time and due to dispersion in the interferometer. The utilization of these two functions brings two major improvements to previous implementations of the MS method. A first improvement consists in reducing the number of channeled spectra necessary to be collected at Master stage. In previous MSI implementation, the number of channeled spectra at the Master stage equated the number of depths where information was selected from at the Slave stage. The paper demonstrates that two experimental channeled spectra only acquired at Master stage suffice to produce A-scans from any number of resolved depths at the Slave stage. A second improvement is the utilization of complex signal processing. Previous MSI implementations discarded the phase. Complex processing of the electrical signal determined by the channeled spectrum allows phase processing that opens several novel avenues. A first consequence of such signal processing is reduction in the random component of the phase without affecting the axial resolution. In previous MSI implementations, phase instabilities were reduced by an average over the wavenumber that led to reduction in the axial resolution.

12 February 2015 in Optics Letters
Verified
Journal Article
Closed access
PDF file
Aymeric Le GratietAymeric Le Gratiet
Aymeric Le Gratiet
SRSylvain Rivet
Sylvain Rivet
MDMatthieu Dubreuil
Matthieu Dubreuil
YGYann Le Grand
Yann Le Grand
A new setup is proposed to perform high-speed Mueller polarimetry by spectral coding of polarization in a reflection configuration. The system uses a swept laser source and a photodiode, which results in a simple optical setup that allows measurement of Mueller matrices at 100 kHz repetition rate. A special focus is made on the influence of the cube beam splitter polarimetric response, which is essential to measurements in a reflection configuration. The instrument is first validated on reference samples for single-point measurements, and the effect of a proper system calibration is also demonstrated on polarimetric images. The device is intended to be implemented within a laser scanning microscope to perform multimodal imaging (confocal/multiphoton and Mueller polarimetry).

2 September 2015 in Optics Express
Verified
Journal Article
Open access
PDF file
SRSylvain Rivet
Sylvain Rivet
ABAdrian Bradu
Adrian Bradu
Adrian PodoleanuAdrian Podoleanu
Adrian Podoleanu
A new set-up is proposed to measure the full polarimetric properties of a sample through an optical fiber, paving the way to full-Mueller endoscopic imaging. The technique combines a channeled spectrum polarimeter and an interferometer. This permits high-speed measurement of two Mueller matrices simultaneously. The first matrix characterizes only the fiber while the second characterizes both fiber and sample. The instrument is validated on vacuum, a quarter-wave plate and a linear polarizer for single-point measurements. Insensitivity of the polarimetric measurement to fiber disturbances is proven while manipulating the fiber.

8 March 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SRSylvain Rivet
Sylvain Rivet
MDMatthieu Dubreuil
Matthieu Dubreuil
Adrian BraduAdrian Bradu
Adrian Bradu
YGYann Le Grand
Yann Le Grand
Mueller microscopes enable imaging of the optical anisotropic properties of biological or non-biological samples, in phase and amplitude, at sub-micrometre scale. However, the development of Mueller microscopes poses an instrumental challenge: the production of polarimetric parameters must be sufficiently quick to ensure fast imaging, so that the evolution of these parameters can be visualised in real-time, allowing the operator to adjust the microscope while constantly monitoring them. In this report, a full Mueller scanning microscope based on spectral encoding of polarization is presented. The spectrum, collected every 10 μs for each position of the optical beam on the specimen, incorporates all the information needed to produce the full Mueller matrix, which allows simultaneous display of all the polarimetric parameters, at the unequalled rate of 1.5 Hz (for an image of 256 × 256 pixels). The design of the optical blocks allows for the real-time display of linear birefringent images which serve as guidance for the operator. In addition, the instrument has the capability to easily switch its functionality from a Mueller to a Second Harmonic Generation (SHG) microscope, providing a pixel-to-pixel matching of the images produced by the two modalities. The device performance is illustrated by imaging various unstained biological specimens.

8 August 2018 in Optics Express
Verified
Journal Article
Open access
PDF file
SRSylvain Rivet
Sylvain Rivet
ABAdrian Bradu
Adrian Bradu
FBFiona Bairstow
Fiona Bairstow
HFHisham Forrière
Hisham Forrière
Adrian PodoleanuAdrian Podoleanu
Adrian Podoleanu
This paper demonstrates that the complex master slave interferometry (CMSI) method used in spectral domain interferometry (SDI) can efficiently be used for accurate refractive index and group velocity dispersion measurements of optically transparent samples. For the first time, we demonstrate the relevance of the phase information delivered by CMSI for dispersion evaluations with no need to linearize data. The technique proposed here has been used to accurately measure the group refractive index and the group velocity dispersion of a strong dispersive sample (SF6 glass), and a weak dispersive one (distilled water). The robustness of the technique is demonstrated through the manipulation of several sets of experimental data.