Yu Liu

Yu Liu

Auto-generated profile, based on publicly available information

Yu Liu

College of Electrical and Information Engineering, Hunan University, Changsha, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 April 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YLYu Liu
Yu Liu
SHSheng Huang
Sheng Huang
LWLiao Wu
Liao Wu
GLGe Liang
Ge Liang
HCHesong Cui
Hesong Cui
SHShoudao Huang
Shoudao Huang
The conventional model predictive torque control (MPTC) used for dual three-phase permanent magnet synchronous motors (DTP-PMSMs) faces several challenges, such as significant computational burden, large current harmonics, and large torque and flux ripples due to the application of imprecise voltage vectors. To address these issues, a novel three-vector-based MPTC strategy was introduced in this study for DTP-PMSMs. First, virtual vectors were adopted to reduce the current harmonic components. Second, four candidate vector groups were determined based on torque deviation and flux position. Each candidate vector group comprised two virtual vectors and one zero vector, which enabled the precise control of torque and flux through the duty-ratio modulation strategy. Third, the switching sequence was optimized to facilitate implementation in digital controllers. Then, a cost function was defined to evaluate the average torque and flux ripples of each candidate vector group in a sampling period, and the one with the minimum cost function was applied in the next sampling period. This approach effectively reduced the current harmonics, torque ripple, and flux ripple while avoiding large computational burden. Finally, experiments were conducted to demonstrate the effectiveness of the proposed method.

4 August 2023 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
GLGe Liang
Ge Liang
SHSheng Huang
Sheng Huang
LWLiao Wu
Liao Wu
ZZZhaoyang Zhang
Zhaoyang Zhang
YLYu Liu
Yu Liu
SHShoudao Huang
Shoudao Huang
Although dual three-phase permanent magnet synchronous motor (DTP-PMSM) exhibits smoother output torque compared to traditional three-phase PMSM, the limitation of switching frequency in high-power industrial equipment can cause a decrease in the carrier ratio, which can lead to greater torque and current harmonics. This paper proposes a novel torque and current harmonics suppression pulse width modulation (TCHSPWM) method for DTP-PMSM that reduces torque and current harmonics under low carrier ratio. In this paper, the analytical formula of electromagnetic torque is derived by deriving the dq -axis current formula under optimized synchronous modulation. The torque analytical formula can be used to directly calculate torque harmonics for different existing optimized synchronous modulation methods. Then, a comprehensive optimization index is proposed using the derived torque and current analytical formulas. Based on this comprehensive optimization index value, the TCHSPWM is constructed to simultaneously suppress the torque and current harmonics of DTP-PMSM by regulating the switching angles of each phase. Comparative experiments have verified the effectiveness of the proposed method, which achieves good torque harmonics suppression while maintaining the ability to suppress current harmonics effectively.

29 August 2023 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
YLYu Liu
Yu Liu
MLMingcheng Lyu
Mingcheng Lyu
SHSheng Huang
Sheng Huang
LWLiao Wu
Liao Wu
GLGe Liang
Ge Liang
SHShoudao Huang
Shoudao Huang
As a dual three-phase permanent magnet synchronous motor (DTP-PMSM) is fed by two DC voltage source inverters (VSIs), the DC-link voltages may become unbalanced. The conventional direct torque control (DTC) schemes under unbalanced DC-link voltages generate large current harmonics and unbalanced stator currents in two sets of windings, which reduce the efficiency and maximum output power of DTP-PMSM. To solve these problems, DTC schemes considering unbalanced DC-link voltages are proposed in this study to improve the performance of DTP-PMSM. First, the variation law of voltage vectors decomposed into the $\bm{\alpha} \text{-} \bm{\beta}$ and x-y subspaces is analyzed under unbalanced DC-link voltages. Then, two or three sets of new virtual vectors synthesized by three nonzero vectors are developed to retain the voltage in the x-y subspace at zero. Moreover, to extend the applicable range, two DTC schemes switch the virtual vector sets with changes in the DC-link voltage ratio ( udc 1 / udc 2 ). Switching points are theoretically analyzed. Subsequently, their performances are analyzed, including DC-link voltage utilization and ripple current. Finally, experiments are performed to verify the feasibility of the proposed schemes in steady-state and dynamic conditions.

15 August 2023 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
YLYu Liu
Yu Liu
XHXiaohui Huang
Xiaohui Huang
SHSheng Huang
Sheng Huang
LWLiao Wu
Liao Wu
GLGe Liang
Ge Liang
SHShoudao Huang
Shoudao Huang
The classical switching-table-based direct torque control (ST-DTC) suffers from issues such as large torque ripples, significant current harmonics, and variable switching frequency. In this paper, a novel ST-DTC is proposed to improve the current and torque steady-state performance for dual three-phase permanent magnet synchronous motor (DTP-PMSM). Firstly, proportional resonance (PR) controllers are used in the x-y subspace, and the x-y reference voltage generated by PR controllers is modulated by three fixed vectors based on the analysis of flux and torque slopes of voltage vectors with different amplitudes. This reduces current harmonics and computational burden of modulating the x-y reference voltage. Secondly, duty-ratio modulation is employed to reduce the torque ripple. However, under the traditional torque regulator, the duty-ratio modulation exists a torque range where it cannot achieve the instantaneous zero error of torque at the end of the control period. Therefore, the feedback value of the torque regulator is modified to further suppress torque ripple. Furthermore, to prevent generating incorrect switch sequences caused by the short dwell time of vectors and maintain the thermal balance of the inverter, an optimization of the switching sequence is performed. Finally, experimental results are presented to validate the effectiveness of the proposed method.

26 August 2024 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
YLYu Liu
Yu Liu
SHSheng Huang
Sheng Huang
LWLiao Wu
Liao Wu
SWShaojie Wang
Shaojie Wang
HTHongwei Tang
Hongwei Tang
SHShoudao Huang
Shoudao Huang
High reliability is one of the primary advantages of the dual three-phase permanent magnet synchronous motor (DTP-PMSM). However, single-phase open-circuit fault in the DTP-PMSM drive suffers from large current harmonics and significant torque ripple. To solve these problems, a fault-tolerant direct torque control (FT-DTC) strategy based on space vector pulse width modulation (SVPWM) is proposed in this paper. Firstly, the component of stator flux on β-axis is modified under postfault. Based on this modified stator flux on β-axis, the stator current and the stator flux maintain the same circular trajectory both pre- and postfault. Secondly, the reference voltage is derived based on the relationship between the stator flux and the stator voltage. Then, the closed-loop controller on z-axis is introduced to suppress current harmonics caused by factors such as dead-time and back electromotive force (EMF) distortion. The output of the closed-loop controller is the harmonic voltage. Furthermore, a novel SVPWM technique is designed to modulate the reference voltage and harmonic voltage. Finally, experimental results demonstrate that the proposed FT-DTC strategy based on SVPWM can achieve high-performance operation under singlephase open-circuit fault.

20 June 2023 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
GLGe Liang
Ge Liang
SHSheng Huang
Sheng Huang
LWLiao Wu
Liao Wu
YLYu Liu
Yu Liu
CFCongqi Feng
Congqi Feng
SHShoudao Huang
Shoudao Huang
Multiple three-phase permanent magnet synchronous generator (MTP-PMSG) has excellent fault-tolerant features in theory. However, the commonly used control architectures, such as the centralized control architecture with only one central controller and the distributed control architecture where the interconnected communication cables between controllers may fail, limit the fault tolerance of MTP-PMSG. Therefore, this article proposes an enhanced distributed control (EDC) architecture without interconnected communication cables of MTP-PMSG for improving redundancy. The sensorless control and harmonic current suppression algorithm are considered and implemented in the EDC architecture. First, this article analyzes the magnetic field coupling between the winding sets of MTP-PMSG, and the variation law of equivalent inductance of the winding sets under the condition of arbitrary current sharing is obtained. Then, an enhanced distributed sensorless control method in EDC architecture is proposed based on the equivalent inductance. Furthermore, this article proposes a model-free predictive harmonic current suppression method to solve the MTP-PMSG's inherent harmonic problem in the EDC architecture. The effectiveness of the proposed methods is verified by the comparative simulations and experiments in a dual three-phase PMSG with arbitrary current sharing of winding sets.