Fault prediction of electromechanical equipment can greatly reduce its maintenance cost and prevent catastrophic damage. In order to realize the accurate fault prediction of electromechanical equipment, a fault prediction method based on spatial-temporal graph information is proposed in this paper. In the proposed method, the signal data of each intermittent monitoring time period are expressed by Markov field graph information, and the spatial-temporal correlation features of graph information are extracted and studied by multivariate spatial-temporal graph neural networks. The effectiveness of Markov graph information for different state expression is demonstrated by motor fault data from motor fault experimental platform, and the bearing fault prognostics data is used to demonstrate the feasibility and accuracy of the proposed fault prediction method. The results show that based on local spatial state information and global time correlation information of monitoring signals, this method could accomplish the accurate long-term and short-term fault prediction tasks respectively.
23 October 2023 in IEEE Transactions on Smart Grid
Natural disasters such as hurricane would cause damages in distribution systems (DSs), resulting in large-scale blackouts. In order to reduce socioeconomic losses under blackouts, it is critical to enhance resilience of DSs through a series of restoration means. Microgrids (MGs) are considered as viable and critical sources to provide emergency power support, and can facilitate restoration of DSs when properly coordinated with the utility-owned control measures. Instead of direct coordination control, this paper proposes a transactive energy (TE) framework for load restoration of DSs, under which the distribution system operator (DSO) organizes a TE market with MGs to trade emergency energy through price signals. Moreover, in order to consider renewable generation uncertainties, a distributionally robust optimization (DRO)-based sequential load restoration model is formulated under the TE framework to maximize the expected restored load with respect to the worst-case probability distribution. Case studies were conducted on the modified IEEE 123 node system. Simulation results show that the proposed strategy can effectively coordinate MGs scheduling to assist in load restoration. Moreover, as compared to the conventional stochastic programming model, the proposed DRO model is less sensitive to the number of scenarios modeled and can produce a more robust solution against out-of-sample scenarios.
29 August 2023 in IEEE Transactions on Energy Conversion
As a dual three-phase permanent magnet synchronous motor (DTP-PMSM) is fed by two DC voltage source inverters (VSIs), the DC-link voltages may become unbalanced. The conventional direct torque control (DTC) schemes under unbalanced DC-link voltages generate large current harmonics and unbalanced stator currents in two sets of windings, which reduce the efficiency and maximum output power of DTP-PMSM. To solve these problems, DTC schemes considering unbalanced DC-link voltages are proposed in this study to improve the performance of DTP-PMSM. First, the variation law of voltage vectors decomposed into the $\bm{\alpha} \text{-} \bm{\beta}$ and x-y subspaces is analyzed under unbalanced DC-link voltages. Then, two or three sets of new virtual vectors synthesized by three nonzero vectors are developed to retain the voltage in the x-y subspace at zero. Moreover, to extend the applicable range, two DTC schemes switch the virtual vector sets with changes in the DC-link voltage ratio ( udc1 / udc2 ). Switching points are theoretically analyzed. Subsequently, their performances are analyzed, including DC-link voltage utilization and ripple current. Finally, experiments are performed to verify the feasibility of the proposed schemes in steady-state and dynamic conditions.
21 January 2021 in IEEE Transactions on Power Electronics
This article presents an enhanced space vector pulse width modulation (SVPWM) strategy based on vector space decomposition (VSD) for the dual three-phase machines fed by two dc-source voltage source inverters (VSIs). Compared with existing methods that only account for balanced dc-link voltages, the proposed method considers unbalanced dc-link voltages in both the α-β and z 1 -z 2 planes. Two categories of medium voltage vectors are first defined in this article. An enhanced 12-sector SVPWM strategy that toggles two categories of medium voltage vectors in each fixed 30° sector is proposed. Moreover, the performance of the proposed method, including the modulation depth, the range of the dc-link voltage ratio, and the toggling point of the medium vector is analyzed. The proposed method can reduce the computational burden of the complicated sector classifications and it easily chooses suitable vectors to track the reference voltage with changes in the dc-link voltage ratio. The experimental results of the proposed SVPWM techniques are verified in a dual three-phase permanent magnet synchronous machine (PMSM) fed by two dc-source VSIs.
15 February 2022 in IEEE Transactions on Power Electronics
In this article, an innovative hybrid position estimation strategy along with the minimum voltage vector injection (MVVI) method and the back electromotive force (back EMF) based method is proposed for interior permanent magnet synchronous motors (IPMSMs) in full-speed regions. At zero- and low-speed, the MVVI method based on rotor saliency is used for position estimation; the inverter voltage error is counteracted in estimating the rotor position, minimizing the inverter nonlinearity effect without introducing external errors. For IPMSMs at the initial state, this article proposes to utilize the high frequency d -axis current excited by injection voltage itself directly for the polarity detection. The position estimation at low-speed based on the MVVI method has such advantages as no requirement for filters, fast convergence, and reliability of magnetic polarity detection. In addition, a smooth transition blends the MVVI method and the back EMF based method is proposed, and a compensation term based on q -axis feedback current is added on the error of both the reference and feedback speed to reject the load-disturbance within the low speed and transition region. Experimental results show that the proposed hybrid sensorless control strategy exhibits excellent performance in the full speed range for both steady-state and dynamic operations.
3 September 2021 in IEEE Transactions on Sustainable Energy
Thanks to its fast self-synchronization capability, the virtual oscillator control (VOC) has become an emerging control technique for grid-connected inverters, especially in single-phase applications. Nevertheless, the nonlinearity of VOC inverters impacts its dynamic behavior, and there is a trade-off between the system stability and accurate power regulation in VOC-based microgrids. This paper studies the dynamic stability of VOC inverters for guiding the parameter design. Then, based on the analysis result, an improved VOC strategy with hybrid power regulation structure is proposed for improving both the system stability and power regulation of VOC-based microgrids. First, a dynamic phasor (DP) model of single-phase VOC-based microgrids with multiple control loops is developed. Second, a stability region analysis of VOC parameters is performed, the proper mode setting and robust parameter design of VOC inverters are provided. Third, the improved VOC strategy is presented, achieving accurate power sharing, fast voltage recovery and adequate stability margin. The proposed parameter design and improved VOC strategy are validated by simulation and hardware-in the-loop experiment.