Ingo Hilschenz

Ingo Hilschenz

Auto-generated profile, based on publicly available information

Ingo Hilschenz

Korean Research Institute of Standards and Science, Daejeon 34113, Republic of Korea

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2013 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
IHIngo Hilschenz
Ingo Hilschenz
RKRainer Körber
Rainer Körber
HSHans-Jürgen Scheer
Hans-Jürgen Scheer
TFTommaso Fedele
Tommaso Fedele
HAHans-Helge Albrecht
Hans-Helge Albrecht
MBMartin Burghoff
Martin Burghoff

1 December 2011 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
NHNora Höfner
Nora Höfner
HAHans-Helge Albrecht
Hans-Helge Albrecht
ACAntonino Mario Cassará
Antonino Mario Cassará
GCGabriel Curio
Gabriel Curio
SHStefan Hartwig
Stefan Hartwig
MBMartin Burghoff
Martin Burghoff

7 June 2010 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
MBMartin Burghoff
Martin Burghoff
HAHans-Helge Albrecht
Hans-Helge Albrecht
SHStefan Hartwig
Stefan Hartwig
IHIngo Hilschenz
Ingo Hilschenz
RKRainer Körber
Rainer Körber
GCGabriel Curio
Gabriel Curio
We describe a nuclear magnetic resonance (NMR) spectrometer operating at 20 μT with a frequency resolution of 2 mHz to determine the intrinsic linewidth of the proton resonance in the human brain to be about 3 Hz. Using the same system we measured a biomagnetic field of 0.5 to 1 pT amplitude, which was generated by sustained brain activity evoked during repetitive median nerve stimulation. From these data, the effect of neuronal currents on the proton NMR signal was estimated. We conclude that neuronal currents may cause a measurable shift of the proton NMR line of brain tissue in low-fields.

1 January 2017 in Journal of Magnetic Resonance
Verified
Journal Article
Closed access
IHIngo Hilschenz
Ingo Hilschenz
YIYosuke Ito
Yosuke Ito
HNHiroaki Natsukawa
Hiroaki Natsukawa
TOTakenori Oida
Takenori Oida
TYTetsuya Yamamoto
Tetsuya Yamamoto
TKTetsuo Kobayashi
Tetsuo Kobayashi

1 August 2019 in Journal of Magnetic Resonance
Verified
Journal Article
Closed access
IHIngo Hilschenz
Ingo Hilschenz
SOSangwon Oh
Sangwon Oh
SLSeong-Joo Lee
Seong-Joo Lee
KYKwon Kyu Yu
Kwon Kyu Yu
SHSeong-Min Hwang
Seong-Min Hwang
JSJeong Hyun Shim
Jeong Hyun Shim

1 January 2011 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
RKRainer Körber
Rainer Körber
GCGabriel Curio
Gabriel Curio
SHStefan Hartwig
Stefan Hartwig
IHIngo Hilschenz
Ingo Hilschenz
NHNora Höfner
Nora Höfner
MBMartin Burghoff
Martin Burghoff
Magnetoencephalography measurements of somatosensory evoked brain activity taken inside an extremely magnetically shielded room are reported. The massive low frequency shielding in combination with a high sampling rate enabled the simultaneous observation of AC and near-DC effects. Neuronal activation was achieved by repetitive electrostimulation of the right median nerve above motor threshold using repetition rates from 3 Hz to 12 Hz. Stimulation sequences lasted for 10 s and were interspersed with periods of rest of equal length. The recorded magnetic fields, inferred for the N20m and a sustained near-DC component, revealed mainly dipolar patterns with mutually rotated orientations with angles of rotation of 30° and 75°. At the start of the stimulation we observed a fast rise within 100 ms in the evoked magnetic near-DC fields for which a maximum equivalent current dipole strength of 65 nAm was obtained. The sustained fields decayed by a factor of ∼4 to a lower DC-level B(γ) with a time constant τ of order of seconds. For 12 Hz repetition rate B(γ) was decreased. We suggest that the sustained neuronal activity evoked by repetitive electrostimulation could provide a suitable scheme to realize the direct detection of DC effects of neuronal currents via low field magnetic resonance.