1 January 2017 in Journal of Magnetic Resonance
1 April 2012 in Journal of Magnetic Resonance
1 October 2018 in Journal of Magnetic Resonance
24 October 2014 in IEEE Sensors Journal
In this paper, we describe a method for directly detecting magnetic resonance (MR) signals using optically pumped atomic magnetometers (OPAMs) in ultra-low-field MR imaging (ULF-MRI). For direct detection with OPAMs in ULF-MRI, we propose the use of an actively shielded bias field tuning coil to match the resonant frequencies between MR signals and OPAM. Design of the tuning coil was based on both a target field approach and a stream function method. The results of field distribution analyses demonstrated that the resonant frequency of an OPAM could be tuned by the actively shielded bias field tuning coil. In addition, the actively shielded bias field tuning coil minimized the distortion of an external magnetic field in the sample region. These results indicate that actively shielded bias field tuning coil can be designed to match the resonant frequencies of MR signal and an OPAM with the inhomogeneity of sample region <;0.25%. However, the actively shielded bias field tuning coil must be fabricated with an error of 0.5 mm or less between the centers of the primary and shield coils.
1 January 2011 in Magnetic Resonance in Medical Sciences
Diffusion tensor imaging (DTI) is a magnetic resonance (MR) imaging technique that has attracted attention in recent years for applications such as nerve fiber tracking, neurography, and tumor detection. In DTI measurements, 2 motion-probing gradient (MPG) pulses are applied to evaluate water diffusion. In DTI for nerve fiber tracking, acquisition parameters, such as strength, duration, and separation of MPGs, influence the MR signal. In this study, we set acquisition parameters in DTI to emphasize fractional anisotropy to clarify the direction of nerve fibers. We performed Monte Carlo simulations of restricted diffusion in a cylinder model and phantom measurements with capillary plates to examine the relationship between the acquisition parameters in DTI and the size of restricted structures, particularly their diameter and length, which we will refer to as “compartment size.” We confirmed that normalized signal intensities in DTI measurements depend on diffusion time, which, in turn, depends on the separation and duration of the MPG, and they decrease with increase in compartment size. Furthermore, our simulation and phantom results suggest that use of a longer diffusion time effectively emphasizes fractional anisotropy to clarify the direction of nerve fibers.
1 January 2006 in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME