Holger Kunze

Holger Kunze

Auto-generated profile, based on publicly available information

Holger Kunze

Siemens Healthineers (Germany)

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2020 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
PWPengwei Wu
Pengwei Wu
NSNiral Sheth
Niral Sheth
ASAlejandro Sisniega
Alejandro Sisniega
AUAli Uneri
Ali Uneri
RHRunze Han
Runze Han
JSJeffrey H Siewerdsen
Jeffrey H Siewerdsen
Metal artifacts present a challenge to cone-beam CT (CBCT) image-guided surgery, obscuring visualization of metal instruments and adjacent anatomy—often in the very region of interest pertinent to the imaging/surgical tasks. We present a method to reduce the influence of metal artifacts by prospectively defining an image acquisition protocol—viz., the C-arm source-detector orbit—that mitigates metal-induced biases in the projection data. The metal artifact avoidance (MAA) method is compatible with simple mobile C-arms, does not require exact prior information on the patient or metal implants, and is consistent with 3D filtered backprojection (FBP), more advanced (e.g. polyenergetic) model-based image reconstruction (MBIR), and metal artifact reduction (MAR) post-processing methods. The MAA method consists of: (i) coarse localization of metal objects in the field-of-view (FOV) via two or more low-dose scout projection views and segmentation (e.g. a simple U-Net) in coarse backprojection; (ii) model-based prediction of metal-induced x-ray spectral shift for all source-detector vertices accessible by the imaging system (e.g. gantry rotation and tilt angles); and (iii) identification of a circular or non-circular orbit that reduces the variation in spectral shift. The method was developed, tested, and evaluated in a series of studies presenting increasing levels of complexity and realism, including digital simulations, phantom experiment, and cadaver experiment in the context of image-guided spine surgery (pedicle screw implants). The MAA method accurately predicted tilted circular and non-circular orbits that reduced the magnitude of metal artifacts in CBCT reconstructions. Realistic distributions of metal instrumentation were successfully localized (0.71 median Dice coefficient) from 2–6 low-dose scout views even in complex anatomical scenes. The MAA-predicted tilted circular orbits reduced root-mean-square error (RMSE) in 3D image reconstructions by 46%–70% and ‘blooming’ artifacts (apparent width of the screw shaft) by 20–45%. Non-circular orbits defined by MAA achieved a further ∼46% reduction in RMSE compared to the best (tilted) circular orbit. The MAA method presents a practical means to predict C-arm orbits that minimize spectral bias from metal instrumentation. Resulting orbits—either simple tilted circular orbits or more complex non-circular orbits that can be executed with a motorized multi-axis C-arm—exhibited substantial reduction of metal artifacts in raw CBCT reconstructions by virtue of higher fidelity projection data, which are in turn compatible with subsequent MAR post-processing and/or polyenergetic MBIR to further reduce artifacts.

12 April 2022 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
FKFlorian Kordon
Florian Kordon
AMAndreas Maier
Andreas Maier
Benedict SwartmanBenedict Swartman
Benedict Swartman
MPMaxim Privalov
Maxim Privalov
JBJan Siad El Barbari
Jan Siad El Barbari
HKHolger Kunze
Holger Kunze
Intricate lesions of the musculoskeletal system require reconstructive orthopedic surgery to restore the correct biomechanics. Careful pre-operative planning of the surgical steps on 2D image data is an essential tool to increase the precision and safety of these operations. However, the plan’s effectiveness in the intra-operative workflow is challenged by unpredictable patient and device positioning and complex registration protocols. Here, we develop and analyze a multi-stage algorithm that combines deep learning-based anatomical feature detection and geometric post-processing to enable accurate pre- and intra-operative surgery planning on 2D X-ray images. The algorithm allows granular control over each element of the planning geometry, enabling real-time adjustments directly in the operating room (OR). In the method evaluation of three ligament reconstruction tasks effect on the knee joint, we found high spatial precision in drilling point localization (ε<2.9mm) and low angulation errors for k-wire instrumentation (ε<0.75∘) on 38 diagnostic radiographs. Comparable precision was demonstrated in 15 complex intra-operative trauma cases suffering from strong implant overlap and multi-anatomy exposure. Furthermore, we found that the diverse feature detection tasks can be efficiently solved with a multi-task network topology, improving precision over the single-task case. Our platform will help overcome the limitations of current clinical practice and foster surgical plan generation and adjustment directly in the OR, ultimately motivating the development of novel 2D planning guidelines.

29 September 2020
Verified
Book Chapter
Closed access
PDF file
FKFlorian Kordon
Florian Kordon
AMAndreas Maier
Andreas Maier
BSBenedict Swartman
Benedict Swartman
MPMaxim Privalov
Maxim Privalov
JBJan Siad El Barbari
Jan Siad El Barbari
HKHolger Kunze
Holger Kunze

18 October 2023 in Physics in Medicine & Biology
Verified
Journal Article
Open access
LML Mekki
L Mekki
NSN M Sheth
N M Sheth
RVR C Vijayan
R C Vijayan
MRM Rohleder
M Rohleder
ASA Sisniega
A Sisniega
AUAli Uneri
Ali Uneri
Objective . Surgical guidewires are commonly used in placing fixation implants to stabilize fractures. Accurate positioning of these instruments is challenged by difficulties in 3D reckoning from 2D fluoroscopy. This work aims to enhance the accuracy and reduce exposure times by providing 3D navigation for guidewire placement from as little as two fluoroscopic images. Approach . Our approach combines machine learning-based segmentation with the geometric model of the imager to determine the 3D poses of guidewires. Instrument tips are encoded as individual keypoints, and the segmentation masks are processed to estimate the trajectory. Correspondence between detections in multiple views is established using the pre-calibrated system geometry, and the corresponding features are backprojected to obtain the 3D pose. Guidewire 3D directions were computed using both an analytical and an optimization-based method. The complete approach was evaluated in cadaveric specimens with respect to potential confounding effects from the imaging geometry and radiographic scene clutter due to other instruments. Main results . The detection network identified the guidewire tips within 2.2 mm and guidewire directions within 1.1°, in 2D detector coordinates. Feature correspondence rejected false detections, particularly in images with other instruments, to achieve 83% precision and 90% recall. Estimating the 3D direction via numerical optimization showed added robustness to guidewires aligned with the gantry rotation plane. Guidewire tips and directions were localized in 3D world coordinates with a median accuracy of 1.8 mm and 2.7°, respectively. Significance . The paper reports a new method for automatic 2D detection and 3D localization of guidewires from pairs of fluoroscopic images. Localized guidewires can be virtually overlaid on the patient’s pre-operative 3D scan during the intervention. Accurate pose determination for multiple guidewires from two images offers to reduce radiation dose by minimizing the need for repeated imaging and provides quantitative feedback prior to implant placement.

9 May 2022 in Journal of Medical Imaging
Verified
Journal Article
Open access
PDF file
CVCelia Martín Vicario
Celia Martín Vicario
FKFlorian Kordon
Florian Kordon
FDFelix Denzinger
Felix Denzinger
JBJan Siad El Barbari
Jan Siad El Barbari
MPMaxim Privalov
Maxim Privalov
HKHolger Kunze
Holger Kunze
Purpose: To assess the result in orthopedic trauma surgery, usually three-dimensional volume data of the treated region is acquired. With mobile C-arm systems, these acquisitions can be performed intraoperatively, reducing the number of required revision surgeries. However, the acquired volumes are typically not aligned to the anatomical regions. Thus, the multiplanar reconstructed (MPR) planes need to be adjusted manually during the review of the volume. To speed up and ease the workflow, an automatic parameterization of these planes is needed. Approach: We present a detailed study of multitask learning (MTL) regression networks to estimate the parameters of the MPR planes. First, various mathematical descriptions for rotation, including Euler angle, quaternion, and matrix representation, are revised. Then, two different MTL network architectures based on the PoseNet are compared with a single task learning network. Results: Using a matrix description rather than the Euler angle description, the accuracy of the regressed normals improves from 7.7 deg to 7.3 deg in the mean value for single anatomies. The multihead approach improves the regression of the plane position from 7.4 to 6.1 mm, whereas the orientation does not benefit from this approach. Thus, the achieved accuracy meets the reported interrater variance in similarly complex body regions of up to 6.3 deg for the normals and up to 9.3 mm for the plane position. Conclusions: The use of a multihead approach with shared features leads to more accurate plane regression compared with the use of individual networks for each task. It also improves the angle estimation for the ankle region. The reported results are in the same range as manual plane adjustments. The use of a combined network with shared parameters requires less memory, which is a great benefit for the implementation of an application for the surgical environment.

7 April 2023
Verified
Conference Paper
Closed access
PDF file
MRMaximilian Rohleder
Maximilian Rohleder
LMLina Mekki
Lina Mekki
AUAli Uneri
Ali Uneri
ASAlex Sisniega
Alex Sisniega
HKHolger Kunze
Holger Kunze
JSJeffrey H. Siewerdsen
Jeffrey H. Siewerdsen
Metal Artifacts remain a problem in Cone-Beam CT (CBCT) imaging, especially reducing clinical value in trauma applications by obscuring the important area around implants. Building on existing Metal Artifact Avoidance (MAA) algorithms, we formulate a metric based on the scatter fraction, introduce a shape model which reduces computational requirements and analyze the feasibility of using only two scout views as prior information. Driven by the observation that orbit optimization requires knowledge of the position, extent, and orientation of metallic objects in the volume of interest (VOI), we devise a shape model in the form of ellipsoids. Reconstructing an ellipsoid from two projection images is not unambiguously possible using analytic methods. By interpreting the problem as probability density estimation, a maximum likelihood fit can be recovered using a Gaussian Mixture Model (GMM). This parametric representation of metal objects is used to efficiently calculate metal pathlength maps for candidate projections on tilted circular trajectories through analytic forward projection. The scatter fraction behind the metal object is modelled as a function of metal pathlength to score views and choose artifact minimizing tilted trajectories. Given two projection images of simulated ellipsoidal objects, the GMM accurately estimates the position and longest axis length within millimeter tolerance. Depending on the orientation relative to the two acquired scout views, an estimation error within the scout-view plane is observed. The generalization on measured data and the shape model hypothesis is verified in a phantom study showing a good correspondence of the modelled metric and observed reduction of artifacts in the tilted CBCT scans. The severity of Metal Artifacts can be reduced by optimizing trajectories on low-fidelity shape models. These surrogate representations can be efficiently estimated from two views for most relative object orientations, but a well-defined ‘blind spot’ remains. The reconstruction error was found to have little effect on tilted orbit optimization if the tilt-axis is contained in the scout-view plane.