2 July 2024 in Astronomy & Astrophysics
Context. The hydrogen deuteride (HD) molecule is an important deuterium tracer in astrophysical studies. The atmospheres of gas giants are dominated by molecular hydrogen, and the simultaneous observation of H2 and HD lines provides reliable information on the D/H ratios on these planets. The reference spectroscopic parameters play a crucial role in such studies. Under the thermodynamic conditions encountered in these atmospheres, spectroscopic studies of HD require not only the knowledge of line intensities and positions but also accurate reference data on pressure-induced line shapes and shifts. Aims. Our aim is to provide accurate collision-induced line-shape parameters for HD lines that cover any thermodynamic conditions relevant to the atmospheres of giant planets, namely any relevant temperature, pressure, and perturbing gas composition (the H2–He mixture). Methods. We performed quantum-scattering calculations on our new, highly accurate ab initio potential energy surface (PES), and we used scattering S matrices obtained in this way to determine the collision-induced line-shape parameters. We used cavity ring-down spectroscopy to validate our theoretical methodology. Results. We report accurate collision-induced line-shape parameters for the pure rotational R(0), R(1), and R(2) lines, the most relevant HD lines for investigations of the atmospheres of the giant planets. Besides the basic Voigt-profile collisional parameters (i.e., the broadening and shift parameters), we also report their speed dependences and the complex Dicke parameter, which can influence the effective width and height of the HD lines up to almost a factor of 2 for giant planet conditions. The sub-percent-level accuracy reached in this work is a considerable improvement over previously available data. All the reported parameters (and their temperature dependences) are consistent with the HITRAN database format, hence allowing for the use of the HITRAN Application Programming Interface (HAPI) for generating the beyond-Voigt spectra of HD.
1 November 2022 in Review of Scientific Instruments
We demonstrate a mirror position actuator that operates in a wide temperature range from room temperature to a deep cryogenic regime (10 K). We use a Michelson interferometer to measure the actuator tuning range (and piezoelectric efficiency) in the full temperature range. We demonstrate an unprecedented range of tunability of the mirror position in the cryogenic regime (over 22 μm at 10 K). The capability of controlling the mirror position in the range from few to few tens of microns is crucial for cavity-enhanced molecular spectroscopy techniques, especially in the important mid-infrared spectral regime where the length of an optical cavity has to be tunable in a range larger than the laser wavelength. The piezoelectric actuator offering this range of tunability in the cryogenic conditions, on the one hand, will enable development of optical cavities operating at low temperatures that are crucial for spectroscopy of large molecules whose dense spectra are difficult to resolve at room temperature. On the other hand, this will enable us to increase the accuracy of the measurement of simple molecules aimed at fundamental studies.
6 March 2026 in Nature Physics
Spectrometers based on high-finesse optical cavities have proven to be powerful tools for applied and fundamental studies. Extending this technology to the deep cryogenic regime reduces Doppler broadening, enhances peak absorption, narrows the Boltzmann distribution of rotational states and ensures that all unwanted molecular species disturbing the spectra are frozen out. Moreover, the dense spectra of complex polyatomic molecules become easier to assign. Here we demonstrate a cavity-enhanced spectrometer fully operating down to 4 K. This was enabled by uniformly cooling, not only the sample, but the entire cavity. Our approach isolates the cavity from external noise and cryocooler vibrations. We demonstrate the capabilities of our cavity-enhanced spectrometer by performing measurements in the deep cryogenic regime: an accurate test of quantum electrodynamics for molecules; the realization of the primary standards of the International System of Units for temperature, concentration and pressure; a measurement of the dihydrogen phase diagram; and the determination of the ortho-to-para spin-isomer conversion rate.
11 May 2026 in SSRN Electronic Journal
We demonstrate a novel platform for cryogenic measurements, recently launched in our laboratory, that is characterized by high stability and high uniformity of temperature, as well as a low level of mechanical noise and vibrations. It allowed us to extend, for the first time, the optical-cavity- enhanced spectroscopy technologies from room temperatures down to a deep cryogenic regime (to below 5 K). The unique feature of the system is a large high-vacuum cryogenic volume of nearly 9 litres and long axial dimension of 78 cm, which makes it well suited for operating optical-cavity-based spectrometers. In order to meet the strict requirements necessary to operate optical resonators, the system is equipped with multiple stages of heavy copper blocks and flexible thermal connectors that altogether not only serve as an excellent low-pass filter for temperature fluctuations (mainly originating from cryocooler operation cycle), but also well isolate the cavity from external noise and cryocooler vibrations. The system design ensures nearly perfect temperature uniformity across the experimental cryogenic chamber that is critical for ultra-accurate spectroscopic measurements at deep cryogenic conditions. Recently, we demonstrated [Nature Physics 22, 637 (2026)] that this system opens a way to new types of measurements that were not possible before, such as an accurate test of the quantum electrodynamics for molecules, realization of the primary SI standards for temperature, concentration, and pressure in the deep cryogenic regime, measurement of the H2 phase diagram, and determination of the ortho-para spin isomer conversion rate.