1 November 2022 in Review of Scientific Instruments
We demonstrate a mirror position actuator that operates in a wide temperature range from room temperature to a deep cryogenic regime (10 K). We use a Michelson interferometer to measure the actuator tuning range (and piezoelectric efficiency) in the full temperature range. We demonstrate an unprecedented range of tunability of the mirror position in the cryogenic regime (over 22 μm at 10 K). The capability of controlling the mirror position in the range from few to few tens of microns is crucial for cavity-enhanced molecular spectroscopy techniques, especially in the important mid-infrared spectral regime where the length of an optical cavity has to be tunable in a range larger than the laser wavelength. The piezoelectric actuator offering this range of tunability in the cryogenic conditions, on the one hand, will enable development of optical cavities operating at low temperatures that are crucial for spectroscopy of large molecules whose dense spectra are difficult to resolve at room temperature. On the other hand, this will enable us to increase the accuracy of the measurement of simple molecules aimed at fundamental studies.
11 May 2026 in SSRN Electronic Journal
We demonstrate a novel platform for cryogenic measurements, recently launched in our laboratory, that is characterized by high stability and high uniformity of temperature, as well as a low level of mechanical noise and vibrations. It allowed us to extend, for the first time, the optical-cavity- enhanced spectroscopy technologies from room temperatures down to a deep cryogenic regime (to below 5 K). The unique feature of the system is a large high-vacuum cryogenic volume of nearly 9 litres and long axial dimension of 78 cm, which makes it well suited for operating optical-cavity-based spectrometers. In order to meet the strict requirements necessary to operate optical resonators, the system is equipped with multiple stages of heavy copper blocks and flexible thermal connectors that altogether not only serve as an excellent low-pass filter for temperature fluctuations (mainly originating from cryocooler operation cycle), but also well isolate the cavity from external noise and cryocooler vibrations. The system design ensures nearly perfect temperature uniformity across the experimental cryogenic chamber that is critical for ultra-accurate spectroscopic measurements at deep cryogenic conditions. Recently, we demonstrated [Nature Physics 22, 637 (2026)] that this system opens a way to new types of measurements that were not possible before, such as an accurate test of the quantum electrodynamics for molecules, realization of the primary SI standards for temperature, concentration, and pressure in the deep cryogenic regime, measurement of the H2 phase diagram, and determination of the ortho-para spin isomer conversion rate.
10 October 2026 in Measurement