Bogdan Bednarski

Mr. Bogdan Bednarski

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 September 2021 in Energies
Verified
Journal Article
Open access
PDF file
BBBogdan Bednarski
Bogdan Bednarski
KJKrzysztof Jackiewicz
Krzysztof Jackiewicz
AGAndrzej Galecki
Andrzej Galecki
Stepper motors are widely used in many applications where discrete, precise movement is required. There is a variety of dedicated stepper motor controllers (sometimes referred to as “step sticks”) available on the market. Those controllers provide a number of different motor control schemes that vary by aspects like current control method, reference current shape or maximum resolution increase (microstepping). The two most widely acknowledged signal shapes are sine-cosine microstepping and quadrature microstepping. The choice of the control scheme impacts torque output, torque variation, positioning error and maximum power supply requirements. This paper presents a family of generalised microstepping signal shapes, ranging from sine-cosine microstepping to quadrature microstepping. Derivation of signal shapes as well as their mathematical analyses are provided. Those signals are then implemented on the control board. A series of experiments is performed on a test bench to analyse the influence of different signal shapes on the performance of the motor in both load and no load conditions. The comparison of the new generalized shapes influence on the motor operation to the commonly used sine-cosine and quadrature control is provided.

11 May 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
KSKamil Leon Sołtys
Kamil Leon Sołtys
MSMichał Słowiński
Michał Słowiński
MMMarcin Makowski
Marcin Makowski
BBBogdan Bednarski
Bogdan Bednarski
KSKamil Stankiewicz
Kamil Stankiewicz
PWPiotr Wcisło
Piotr Wcisło
We demonstrate a novel platform for cryogenic measurements, recently launched in our laboratory, that is characterized by high stability and high uniformity of temperature, as well as a low level of mechanical noise and vibrations. It allowed us to extend, for the first time, the optical-cavity- enhanced spectroscopy technologies from room temperatures down to a deep cryogenic regime (to below 5 K). The unique feature of the system is a large high-vacuum cryogenic volume of nearly 9 litres and long axial dimension of 78 cm, which makes it well suited for operating optical-cavity-based spectrometers. In order to meet the strict requirements necessary to operate optical resonators, the system is equipped with multiple stages of heavy copper blocks and flexible thermal connectors that altogether not only serve as an excellent low-pass filter for temperature fluctuations (mainly originating from cryocooler operation cycle), but also well isolate the cavity from external noise and cryocooler vibrations. The system design ensures nearly perfect temperature uniformity across the experimental cryogenic chamber that is critical for ultra-accurate spectroscopic measurements at deep cryogenic conditions. Recently, we demonstrated [Nature Physics 22, 637 (2026)] that this system opens a way to new types of measurements that were not possible before, such as an accurate test of the quantum electrodynamics for molecules, realization of the primary SI standards for temperature, concentration, and pressure in the deep cryogenic regime, measurement of the H2 phase diagram, and determination of the ortho-para spin isomer conversion rate.

10 October 2026 in Measurement
Verified
Journal Article
Open access
KSKamil Leon Sołtys
Kamil Leon Sołtys
MSMichał Słowiński
Michał Słowiński
MMMarcin Makowski
Marcin Makowski
BBBogdan Bednarski
Bogdan Bednarski
KSKamil Stankiewicz
Kamil Stankiewicz
PWPiotr Wcisło
Piotr Wcisło