Giuseppe Cavuoto

Giuseppe Cavuoto

Auto-generated profile, based on publicly available information

Giuseppe Cavuoto


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

12 September 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
GCGiuseppe Cavuoto
Giuseppe Cavuoto
DPDiego Pugliese
Diego Pugliese
VDVincenzo Della Donna
Vincenzo Della Donna
AVAlessio Verna
Alessio Verna
AFAlessio Facello
Alessio Facello
SMSimone Luigi Marasso
Simone Luigi Marasso
Micro-Coriolis mass flow sensors offer a promising approach for the measurement of low flow rates and fluid density, but conventional silicon-based implementations often require complex and costly fabrication processes. In this work, we present the development and experimental characterization of a fully polymeric MEMS (Micro Electro Mechanical Systems) Coriolis microsensor fabricated using SU-8 100. The device consists of a suspended Ω-shaped microfluidic channel enclosed between two independently fabricated SU-8 layers and assembled by thermocompression bonding under vacuum condition. A maskless laser direct writing process was adopted to enable rapid optimization of the device geometry and fabrication parameters. Particular attention was devoted to the optimization of the bonding process, for which a temperature range from (125 to 135) ◦C, an applied load from (320 to 400) N, and a bonding time of 2 min were identified as the most suitable conditions, providing reliable sealing while preserving the microchannel geometry. The fabricated devices exhibited leak-tight operation up to approximately 1200 mbar and enabled flow rates of up to 200 µL/min. The dynamic response of the microsensor was subsequently investigated by measuring the resonance frequency of the suspended microchannel for fluids with different densities. A quadratic calibration model based on the frequency shift relative to the air-filled condition was established over a density range between (0.78 and 1.07) g/cm3. The resulting density measurements exhibited an expanded relative uncertainty of 1.21 % (k = 2). Independent validation using ethanol, n-nonane, APN26, and APN415 yielded deviations between -0.31 % and 0.20 % from the corresponding reference densities. These results demonstrate the feasibility of SU-8-based MEMS technology for integrated fluid-density sensing and provide a pave the way for the further development of low-cost polymeric micro-Coriolis devices for microfluidic and metrological applications.