Matthias Hügle

Matthias Hügle

Auto-generated profile, based on publicly available information

Matthias Hügle

Institute of Microbiology and Virology, Brandenburg Medical School Theodor Fontane, 16816 Neuruppin, Germany

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JWJohannes Wöhrle
Johannes Wöhrle
SKStefan Krämer
Stefan Krämer
PMPhilipp A. Meyer
Philipp A. Meyer
CRChristin Rath
Christin Rath
MHMatthias Hügle
Matthias Hügle
GRGünter Roth
Günter Roth
In this work we show how DNA microarrays can be produced batch wise on standard microscope slides in a fast, easy, reliable and cost-efficient way. Contrary to classical microarray generation, the microarrays are generated via digital solid phase PCR. We have developed a cavity-chip system made of a PDMS/aluminum composite which allows such a solid phase PCR in a scalable and easy to handle manner. For the proof of concept, a DNA pool composed of two different DNA species was used to show that digital PCR is possible in our chips. In addition, we demonstrate that DNA microarray generation can be realized with different laboratory equipment (slide cycler, manually in water baths and with an automated cartridge system). We generated multiple microarrays and analyzed over 13,000 different monoclonal DNA spots to show that there is no significant difference between the used equipment. To show the scalability of our system we also varied the size and number of the cavities located in the array region up to more than 30,000 cavities with a volume of less than 60 pL per cavity. With this method, we present a revolutionary tool for novel DNA microarrays. Together with new established label-free measurement systems, our technology has the potential to give DNA microarray applications a new boost.

19 February 2020 in The Analyst
Verified
Journal Article
Closed access
PDF file
MHMatthias Hügle
Matthias Hügle
OBOle Behrmann
Ole Behrmann
MRMadlen Raum
Madlen Raum
FHFrank T. Hufert
Frank T. Hufert
GUGerald A. Urban
Gerald A. Urban
GDGregory Dame
Gregory Dame
Nucleic acid amplification techniques such as real-time PCR are essential instruments for the identification and quantification of viruses. They are fast, very sensitive and highly specific, but often require elaborate and labor intensive sample preparation to achieve successful amplification of the target sequence. In this work we demonstrate the complete microfluidic preparation of amplifiable virus DNA from dilute specimens. Our approach combines free-flow electrophoretic preconcentration of viral particles with thermal lysis and gel-electrophoretic nucleic acid extraction on a single device. The on-chip preconcentration achieves a capture efficiency of >99% for dilute suspensions of bacteriophage PhiX174. Following preconcentration, phages are thermally lysed and released DNA is recovered after 40 s of on-chip gel-electrophoresis with a recovery rate of ∼73%. Furthermore we demonstrate a detection limit of ∼1 PFU ml−1 (∼0.02 DNA copies per μl) for the detection of bacteriophage PhiX174 by PCR. To simplify operation of the device, we describe the development of a custom-made chip holder as well as a compact peristaltic pump and power supply, which enable user-friendly operation with low risk of cross-contamination and high potential for automation in the field of point-of-care diagnostics.

1 June 2018 in RSC Advances
Verified
Journal Article
Open access
PDF file
MHM. Hügle
M. Hügle
GDG. Dame
G. Dame
OBO. Behrmann
O. Behrmann
RRR. Rietzel
R. Rietzel
DKDaniel Karthe
Daniel Karthe
GUG. A. Urban
G. A. Urban
To improve detection sensitivity, molecular diagnostics require preconcentration of low concentrated samples followed by rapid nucleic acid extraction. This is usually achieved by multiple centrifugation, lysis and purification steps, for instance, using chemical reagents, spin columns or magnetic beads. These require extensive infrastructure as well as time consuming manual handling steps and are thus not suitable for point of care testing (POCT). To overcome these challenges, we developed a microfluidic chip combining free-flow electrophoretic (FFE) preconcentration (1 ml down to 5 μl) and thermoelectric lysis of bacteria as well as purification of nucleic acids by gel-electrophoresis. The integration of these techniques in a single chip is unique and enables fast, easy and space-saving sample pretreatment without the need for laboratory facilities, making it ideal for the integration into small POCT devices. A preconcentration efficiency of nearly 100% and a lysis/gel-electrophoresis efficiency of about 65% were achieved for the detection of E. coli. The genetic material was analyzed by RT-qPCR targeting the superfolder Green Fluorescent Protein (sfGFP) transcripts to quantify mRNA recovery and qPCR to determine DNA background.

17 June 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
OBOle Behrmann
Ole Behrmann
MHMatthias Hügle
Matthias Hügle
FEFranz Eckardt
Franz Eckardt
IBIris Bachmann
Iris Bachmann
CHCecilia Heller
Cecilia Heller
GDGregory Dame
Gregory Dame
We investigate the compatibility of three 3D printing materials towards real-time recombinase polymerase amplification (rtRPA). Both the general ability of the rtRPA reaction to occur while in contact with the cured 3D printing materials as well as the residual autofluorescence and fluorescence drift in dependence on post curing of the materials is characterized. We 3D printed monolithic rtRPA microreactors and subjected the devices to different post curing protocols. Residual autofluorescence and drift, as well as rtRPA kinetics, were then measured in a custom-made mobile temperature-controlled fluorescence reader (mTFR). Furthermore, we investigated the effects of storage on the devices over a 30-day period. Finally, we present the single- and duplex rtRPA detection of both the organism-specific Klebsiella haemolysin (khe) gene and the New Delhi metallo-β-lactamase 1 (blaNDM-1) gene from Klebsiella pneumoniae. Results: No combination of 3D printing resin and post curing protocol completely inhibited the rtRPA reaction. The autofluorescence and fluorescence drift measured were found to be highly dependent on printing material and wavelength. Storage had the effect of decreasing the autofluorescence of the investigated materials. Both khe and blaNDM-1 were successfully detected by single- and duplex-rtRPA inside monolithic rtRPA microreactors printed from NextDent Ortho Clear (NXOC). The reaction kinetics were found to be close to those observed for rtRPA performed in a microcentrifuge tube without the need for mixing during amplification. Singleplex assays for both khe and blaNDM-1 achieved a limit of detection of 2.5 × 101 DNA copies while the duplex assay achieved 2.5 × 101 DNA copies for khe and 2.5 × 102 DNA copies for blaNDM-1. Impact: We expand on the state of the art by demonstrating a technology that can manufacture monolithic microfluidic devices that are readily suitable for rtRPA. The devices exhibit very low autofluorescence and fluorescence drift and are compatible with RPA chemistry without the need for any surface pre-treatment such as blocking with, e.g., BSA or PEG.

1 May 2015 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
SHS. Hakenberg
S. Hakenberg
MHM. Hügle
M. Hügle
PMP. Meyer
P. Meyer
OBO. Behrmann
O. Behrmann
GDGregory Dame
Gregory Dame
GUG.A. Urban
G.A. Urban

30 August 2017 in Proceedings
Verified
Conference Paper
Open access
PDF file
RRRichard Rietzel
Richard Rietzel
MHMatthias Hügle
Matthias Hügle
GDGregory Dame
Gregory Dame
OBOle Behrmann
Ole Behrmann
GUGerald A. Urban
Gerald A. Urban
We present a novel approach for the efficiency enhancement of microfluidic bacteria enrichment systems based on free-flow electrophoresis (FFE). FFE efficiency is highly dependent on the electrophoretic mobility μ of the bacteria. As μ varies strongly with the suspension medium, fast and accurate determination of μ is needed to achieve optimal enrichment performance from different suspension media. For the first time, μ is determined in-situ for multiple media during on-chip FFE by Particle Image Velocimetry (PIV) of fluorescent bacteria, obviating the need for separate measurement equipment or chemical staining of the bacteria.