28 November 2023 in Journal of Materials Research and Technology
SRSanjay Mavinkere Rangappa
Sanjay Mavinkere Rangappa
1 January 2017 in AIP Conference Proceedings
Eco-friendly, green, and natural materials have become increasingly important issues in supporting sustainable development, for the substitution of nonrenewable materials such as steel. Bamboo has been considered in many studies to replace steel in reinforced concrete elements. Further investigation has been carried out to obtain lightweight and eco-friendly reinforced concrete slabs by using bamboo bars as reinforcement and recycled materials such as EPS (expanded polystyrene) as infill panel. The flexural loading test on full scale one-way slabs test has been conducted. The results showed that the flexural strength of specimens decreased marginally of about 6% but with the weight advantage of 27% less compared with those of steel rebar reinforced concrete slab with the same dimension. Two type shear-connectors comprising of concrete and bamboo studs were also investigated which showed that the bamboo stud provided better ductility compared to that of slab with concrete as shear connector. Overall, the reinforced concrete slab with bamboo reinforcement and EPS infill panel showed reasonably good performance compared to slabs with steel rebar.
9 March 2017 in MATEC Web of Conferences
MATEC Web of Conferences, open access proceedings in Materials science, Engineering and Chemistry
1 July 2021 in Journal of Water and Land Development
A flood occurs for many reasons, such as excessive rainfall, runoff coefficient, or an insufficient river channel capacity. The discharge flowing through the floodway depends on the maximum main river dimension that can be normalized. LU/LC changes are affected by runoff discharge, and runoff discharge is affected by the floodway design. The study dis-cusses the effect of land use (LU) or land cover (LC) changes and the design of floodway channel dimensions in the Kali Kemuning watershed, East Java Province, Indonesia. The Nakayasu synthetic unit hydrograph has been used to analyse the runoff discharge, and the Hydrologic Engineering Center’s River Analysis System software analysed the hydraulic proper-ties of river and floodway channels. Results show that the floodway channel design is determined by LU/LC conditions, and the river channel is normalized toward its maximum dimensions. Normalized channel depths and widths vary from 4 to 7 m and 16 to 46 m, respectively. The floodway channel is rectangular, with a bottom width of 10 m and depth of 4.5 m. With the runoff coefficient equal to 0.75, these normalized channel and floodway dimensions are suitable for the flood up to the 100-year return period runoff discharge.
2 February 2024 in Journal of Law and Sustainable Development
Purpose: This research intends to examine inclined pile structures to analyze the effectiveness of inclined pile structures by analyzing the relationship between the transmission coefficient and wave steepness based on several parameters including pile slope (α), the distance between the piles in one row (D), distance between the top of the piles (b), depth (d), wave height (H) and wave period (T). Theoretical reference: Wave breaking structures are widely used to protect beaches from the impact of sea waves that propagate to coastal areas. Wave breakers are coastal structures that are used to withstand and break the height of waves coming towards the beach, so that the area behind the breakwater does not receive much influence from the waves. When passing through coastal buildings, the waves will be reflected (reflection) and forwarded (transmission). Method: Physical laboratory simulations have been carried out to obtain wave data interacting with the inclined pile structure. Next, energy spectrum analysis was carried out to determine the energy spectrum of incident, reflection and transmission waves from wave probe measurements in the form of time series data. Each energy spectrum is used to see the reflection and transmission capabilities of the pile structure from the reflection and transmission coefficients. Result and Conclusion: From this research it is known that in general Kt has an inverse relationship to wave steepness value (Hi/gT2 and Hi⁄ L). The most effective water level for this breakwater is the average water level. The most effective spacing scenario is α=600 scenario; D=1.69cm; b= 5 cm with a Kt value of 0.652 at Hi/gT2 of 0.006, Kr= 0.103 and Kd= 0.245, so only 65.2% of the waves can pass through the structure, 10.3% is reflected, and 24.5% is removed. Implication of research: These lost waves can be caused by waves traveling through the inclined pile structure, due to collisions between waves or other things. Originality/ value: One of the wave breaker innovations that are being developed is the pile structure. Currently, a lot of research has been carried out regarding upright pile structures.
1 January 2017 in AIP Conference Proceedings
Sustainable development has become an important issue due to the increasing consideration of preserving the nature. Many alternative for coarse aggregate replacement have been investigated ranging from natural and fabricated aggregates. In this study, natural aggregate pumice was investigated since it offers lower density that give paramount benefit in reducing total building weight and hence reducing the earthquake excitation effect and optimizing the structural dimension. However, the characteristic of porous surfaces of pumice causes excessive water absorption during concrete mixing process. Therefore, to reduce the additional water, the pumice aggregates were coated with polymer. The tested specimens consisted of normal concrete beams (NCB), uncoated pumice aggregate concrete beam (UPA) and polymer coated pumice aggregate concrete beam (PCP). The objective of the research was to obtain the effect of coating on the pumice aggregate to the flexural behavior of concrete beams. The lateral load-displacement behavior, ductility and collapse mechanism were studied. The results showed that there were only marginal drop on the load-carrying capacity of the pumice aggregate beam compared to those of normal beam. Additionally, the ductility coefficient of specimens UPA and PCP decreased of 11,97% and 14,03% respectively compared to NCB, and the ultimate load capacity decreased less than 1%. Overall, the pumice aggregate showed good characteristic for replacing normal coarse aggregate.