Rachel E. McCarroll

Rachel E. McCarroll

Auto-generated profile, based on publicly available information

Rachel E. McCarroll

Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, UNITED STATES

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2018 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Closed access
CCCarlos E. Cardenas
Carlos E. Cardenas
RMRachel E. McCarroll
Rachel E. McCarroll
LCLaurence Edward Court
Laurence Edward Court
BEBaher A. Elgohari
Baher A. Elgohari
HEHesham Elhalawani
Hesham Elhalawani
MAMichalis Aristophanous
Michalis Aristophanous

1 November 2018 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
CCCarlos E. Cardenas
Carlos E. Cardenas
BABrian Mark Anderson
Brian Mark Anderson
MAMichalis Aristophanous
Michalis Aristophanous
Jinzhong YangJinzhong Yang
Jinzhong Yang
DRDong Joo Rhee
Dong Joo Rhee
LCLaurence E Court
Laurence E Court
Accurate clinical target volume (CTV) delineation is essential to ensure proper tumor coverage in radiation therapy. This is a particularly difficult task for head-and-neck cancer patients where detailed knowledge of the pathways of microscopic tumor spread is necessary. This paper proposes a solution to auto-segment these volumes in oropharyngeal cancer patients using a two-channel 3D U-Net architecture. The first channel feeds the network with the patient’s CT image providing anatomical context, whereas the second channel provides the network with tumor location and morphological information. Radiation therapy simulation computer tomography scans and their corresponding manually delineated CTV and gross tumor volume (GTV) delineations from 285 oropharyngeal patients previously treated at MD Anderson Cancer Center were used in this study. CTV and GTV delineations underwent rigorous group peer-review prior to the start of treatment delivery. The convolutional network’s parameters were fine-tuned using a training set of 210 patients using 3-fold cross-validation. During hyper-parameter selection, we use a score based on the overlap (dice similarity coefficient (DSC)) and missed volumes (false negative dice (FND)) to minimize any possible under-treatment. Three auto-delineated models were created to estimate tight, moderate, and wide CTV margin delineations. Predictions on our test set (75 patients) resulted in auto-delineations with high overlap and close surface distance agreement (DSC > 0.75 on 96% of cases for tight and moderate auto-delineation models and 97% of cases having mean surface distance ⩽ 5.0 mm) to the ground-truth. We found that applying a 5 mm uniform margin expansion to the auto-delineated CTVs would cover at least 90% of the physician CTV volumes for a large majority of patients; however, determination of appropriate margin expansions for auto-delineated CTVs merits further investigation.

19 January 2017 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
RMRachel E. McCarroll
Rachel E. McCarroll
BBBeth M. Beadle
Beth M. Beadle
DFDanna Fullen
Danna Fullen
PBPeter A. Balter
Peter A. Balter
DFDavid S. Followill
David S. Followill
LCLaurence Edward Court
Laurence Edward Court
Radiotherapy in a seated position may be indicated for patients who are unable to lie on the treatment couch for the duration of treatment, in scenarios where a seated treatment position provides superior anatomical positioning and dose distributions, or for a low‐cost system designed using a fixed treatment beam and rotating seated patient. In this study, we report a novel treatment chair that was constructed to allow for three‐dimensional imaging and treatment delivery while ensuring robust immobilization, providing reproducibility equivalent to that in the traditional supine position. Five patients undergoing radiation treatment for head‐and‐neck cancers were enrolled and were setup in the chair, with immobilization devices created, and then imaged with orthogonal X‐rays in a scenario that mimicked radiation treatments (without treatment delivery). Six subregions of the acquired images were rigidly registered to evaluate intra‐ and interfraction displacement and chair construction. Displacements under conditions of simulated image guidance were acquired by first registering one subregion; the residual displacement of other subregions was then measured. Additionally, we administered a patient questionnaire to gain patient feedback and assess comparison to the supine position. Average inter‐ and intrafraction displacements of all subregions in the seated position were less than 2 and 3 mm, respectively. When image guidance was simulated, L‐R and A‐P interfraction displacements were reduced by an average of 1 mm, providing setup of comparable quality to supine setups. The enrolled patients, who had no indication for a seated treatment position, reported no preference in the seated or the supine position. The novel chair design provides acceptable inter‐ and intrafraction displacement, with reproducibility equivalent to that reported for patients in the supine position. Patient feedback will be incorporated in the refinement of the chair, facilitating treatment of head‐and‐neck cancer in patients who are unable to lie for the duration of treatment or for use in an economical fixed‐beam setup.

11 April 2018 in Journal of Visualized Experiments
Verified
Journal Article
Open access
PDF file
LCLaurence Edward Court
Laurence Edward Court
KKKelly Kisling
Kelly Kisling
RMRachel McCarroll
Rachel McCarroll
LZLifei Zhang
Lifei Zhang
JYJinzhong Yang
Jinzhong Yang
BBBeth Beadle
Beth Beadle
The Radiation Planning Assistant (RPA) is a system developed for the fully automated creation of radiotherapy treatment plans, including volume-modulated arc therapy (VMAT) plans for patients with head/neck cancer and 4-field box plans for patients with cervical cancer. It is a combination of specially developed in-house software that uses an application programming interface to communicate with a commercial radiotherapy treatment planning system. It also interfaces with a commercial secondary dose verification software. The necessary inputs to the system are a Treatment Plan Order, approved by the radiation oncologist, and a simulation computed tomography (CT) image, approved by the radiographer. The RPA then generates a complete radiotherapy treatment plan. For the cervical cancer treatment plans, no additional user intervention is necessary until the plan is complete. For head/neck treatment plans, after the normal tissue and some of the target structures are automatically delineated on the CT image, the radiation oncologist must review the contours, making edits if necessary. They also delineate the gross tumor volume. The RPA then completes the treatment planning process, creating a VMAT plan. Finally, the completed plan must be reviewed by qualified clinical staff.

1 October 2017 in Journal of Global Oncology
Verified
Journal Article
Open access
RMRachel McCarroll
Rachel McCarroll
BYBassem Youssef
Bassem Youssef
BBBeth Beadle
Beth Beadle
MBMaureen Bojador
Maureen Bojador
RCRex Cardan
Rex Cardan
LCLaurence Court
Laurence Court
Purpose: More than 6,500 megavoltage teletherapy units are needed worldwide, many in low-resource settings. Cobalt-60 units or linear accelerators (linacs) can fill this need. We have evaluated machine performance on the basis of patient throughput to provide insight into machine viability under various conditions in such a way that conclusions can be generalized to a vast array of clinical scenarios. Materials and Methods: Data from patient treatment plans, peer-reviewed studies, and international organizations were combined to assess the relative patient throughput of linacs and cobalt-60 units that deliver radiotherapy with standard techniques under various power and maintenance support conditions. Data concerning the frequency and duration of power outages and downtime characteristics of the machines were used to model teletherapy operation in low-resource settings. Results: Modeled average daily throughput was decreased for linacs because of lack of power infrastructure and for cobalt-60 units because of limited and decaying source strength. For conformal radiotherapy delivered with multileaf collimators, average daily patient throughput over 8 years of operation was equal for cobalt-60 units and linacs when an average of 1.83 hours of power outage occurred per 10-hour working day. Relative to conformal treatments delivered with multileaf collimators on the respective machines, the use of advanced techniques on linacs decreased throughput between 20% and 32% and, for cobalt machines, the need to manually place blocks reduced throughput up to 37%. Conclusion: Our patient throughput data indicate that cobalt-60 units are generally best suited for implementation when machine operation might be 70% or less of total operable time because of power outages or mechanical repair. However, each implementation scenario is unique and requires consideration of all variables affecting implementation.

1 September 2015
Verified
Journal Article
Closed access
RMRachel E McCarroll
Rachel E McCarroll
ARAshley E Rubinstein
Ashley E Rubinstein
CKCharles V Kingsley
Charles V Kingsley
Jinzhong YangJinzhong Yang
Jinzhong Yang
PYPeiying Yang
Peiying Yang
LCLaurence Edward Court
Laurence Edward Court