Derek N. Wolf

Derek N. Wolf

Auto-generated profile, based on publicly available information

Derek N. Wolf

Vanderbilt University

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2022 in Journal of Sports Sciences
Verified
Journal Article
Open access
LELaura Elstub
Laura Elstub
CNCameron Alexander Nurse
Cameron Alexander Nurse
LGL.M Grohowski
L.M Grohowski
PVPeter Volgyesi
Peter Volgyesi
DWD.N Wolf
D.N Wolf
KZKarl E Zelik
Karl E Zelik
Tibial bone stress injury is a common overuse injury experienced by runners, which results from repetitive tissue forces. Wearable sensor systems (wearables) that monitor tibial forces could help understand and reduce injury incidence. However, there are currently no validated wearables that monitor tibial bone forces. Previous work using simulated wearables demonstrated accurate tibial force estimates by combining a shoe-worn inertial measurement unit (IMU) and pressure insole with a trained algorithm. This study aimed assessed how accurately tibial bone forces could be estimated with existing wearables. Nine recreational runners ran at a series of different speeds and slopes, and with various stride patterns. Shoe-worn IMU and insole data were input into a trained algorithm to estimate peak tibial force. We found an average error of 5.7% in peak tibial force estimates compared with lab-based estimates calculated using motion capture and a force instrumented treadmill. Insole calibration procedures were essential to achieving accurate tibial force estimates. We concluded that a shoe-worn, multi-sensor system is a promising approach to monitoring tibial bone forces in running. This study adds to the literature demonstrating the potential of wearables to monitor musculoskeletal forces, which could positively impact injury prevention, and scientific understanding.

20 August 2018 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
DWDerek N. Wolf
Derek N. Wolf
ESEric M. Schearer
Eric M. Schearer
Functional electrical stimulation (FES) is a promising solution for restoring functional motion to individuals with paralysis, but the potential for achieving any desired full-arm reaching motion has not been realized. We present a combined feedforward-feedback controller capable of automatically calculating and applying the necessary muscle stimulations to hold the wrist of an individual with high tetraplegia in a desired static position. We used the controller to hold a complete arm configuration to maintain a series of static wrist positions. The average distance to the target wrist position, or accuracy, was 2.9 cm. The precision is defined as the radius of the 95% confidence ellipsoid for the final positions of a set of trials with the same muscle stimulations and starting position. The average precision was 3.7 cm. The control architecture used in this study to hold static positions has the potential to control arbitrary reaching motions.

25 January 2022 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
DWDerek N. Wolf
Derek N. Wolf
ESEric M. Schearer
Eric M. Schearer
Functional electrical stimulation (FES) offers promise as a technology to restore reaching motions to individuals with spinal cord injuries. To date, the level of reaching necessary for everyday use has not been achieved due to the complexity and limitations of the arm and muscles of an individual with a spinal cord injury. To improve the performance of FES-driven reaching controllers, we developed a trajectory optimization and model predictive control scheme that incorporates knowledge of the person-specific muscle capabilities and arm dynamics. Our controller achieved 3D reaching motions with an average accuracy of 8.5 cm and demonstrated an ability to reach targets throughout the workspace. With improvements to the model, this control scheme has the potential to unlock many daily reaching tasks for individuals with spinal cord injuries.

13 November 2022 in Journal of Biomechanics
Verified
Journal Article
Closed access
LEL.J. Elstub
L.J. Elstub
LGL.M. Grohowski
L.M. Grohowski
DWD.N. Wolf
D.N. Wolf
MOM.K. Owen
M.K. Owen
BNB. Noehren
B. Noehren
KZK.E. Zelik
K.E. Zelik

1 July 2017 in IEEE International Conference on Rehabilitation Robotics (ICORR)
Verified
Conference Paper
Closed access
DWDerek N. Wolf
Derek N. Wolf
ESEric M. Schearer
Eric M. Schearer
Functional electrical stimulation (FES) is a promising solution for restoring functional motion to individuals with paralysis, but the potential for achieving full-arm reaching motions with FES for various desired tasks has not been realized. We present an open-loop controller capable of calculating and applying the necessary muscle stimulations to hold the wrist of an individual with high tetraplegia at any desired position. We used the controller to hold the wrist at a series of static positions. The controller was capable of discriminating between different wrist positions. The average distance to the target wrist position, or accuracy, was 7.7 cm. The average radius of the 95% confidence ellipsoid for a set of trials with the same muscle stimulations, or precision, was 6.7 cm. Adding feedback or online model updates will likely improve the accuracy for tasks requiring finer control. The controller is a good first step to controlling full-arm motions with FES.

4 May 2023 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
DWDerek N. Wolf
Derek N. Wolf
ABAntonie J. van Den Bogert
Antonie J. van Den Bogert
ESEric M. Schearer
Eric M. Schearer
Functional electrical stimulation (FES) is a promising technology for restoring reaching motions to individuals with upper-limb paralysis caused by a spinal cord injury (SCI). However, the limited muscle capabilities of an individual with SCI have made achieving FES-driven reaching difficult. We developed a novel trajectory optimization method that used experimentally measured muscle capability data to find feasible reaching trajectories. In a simulation based on a real-life individual with SCI, we compared our method to attempting to follow naive direct-to-target paths. We tested our trajectory planner with three control structures that are commonly used in applied FES: feedback, feedforward-feedback, and model predictive control. Overall, trajectory optimization improved the ability to reach targets and improved the accuracy for the feedforward-feedback and model predictive controllers ( ${p}< {0}.{001}$ ). The trajectory optimization method should be practically implemented to improve the FES-driven reaching performance.