28 April 2016 in Catheterization and Cardiovascular Interventions
1 December 2016 in Journal of Cardiovascular Magnetic Resonance
4D Multiphase Steady State Imaging with Contrast (MUSIC) acquires high-resolution volumetric images of the beating heart during uninterrupted ventilation. We aim to evaluate the diagnostic performance and clinical impact of 4D MUSIC in a cohort of neonates and infants with congenital heart disease (CHD). Forty consecutive neonates and infants with CHD (age range 2 days to 2 years, weight 1 to 13 kg) underwent 3.0 T CMR with ferumoxytol enhancement (FE) at a single institution. Independently, two readers graded the diagnostic image quality of intra-cardiac structures and related vascular segments on FE-MUSIC and breath held FE-CMRA images using a four-point scale. Correlation of the CMR findings with surgery and other imaging modalities was performed in all patients. Clinical impact was evaluated in consensus with referring surgeons and cardiologists. One point was given for each of five key outcome measures: 1) change in overall management, 2) change in surgical approach, 3) reduction in the need for diagnostic catheterization, 4) improved assessment of risk-to-benefit for planned intervention and discussion with parents, 5) accurate pre-procedural roadmap. All FE-CMR studies were completed successfully, safely and without adverse events. On a four-point scale, the average FE-MUSIC image quality scores were >3.5 for intra-cardiac structures and >3.0 for coronary arteries. Intra-cardiac morphology and vascular anatomy were well visualized with good interobserver agreement (r = 0.46). Correspondence between the findings on MUSIC, surgery, correlative imaging and autopsy was excellent. The average clinical impact score was 4.2 ± 0.9. In five patients with discordant findings on echo/MUSIC (n = 5) and catheter angiography/MUSIC (n = 1), findings on FE-MUSIC were shown to be accurate at autopsy (n = 1) and surgery (n = 4). The decision to undertake biventricular vs univentricular repair was amended in 2 patients based on FE-MUSIC findings. Plans for surgical approaches which would have involved circulatory arrest were amended in two of 28 surgical cases. In all 28 cases requiring procedural intervention, FE-MUSIC provided accurate dynamic 3D roadmaps and more confident risk-to-benefit assessments for proposed interventions. FE-MUSIC CMR has high clinical impact by providing accurate, high quality, simple and safe dynamic 3D imaging of cardiac and vascular anatomy in neonates and infants with CHD. The findings influenced patient management in a positive manner.
15 April 2020 in World Journal for Pediatric and Congenital Heart Surgery
We aimed to evaluate the utility of computed tomography angiography (CTA) for coronary compression (CC) prediction in patients with congenital heart disease undergoing balloon-expandable transcatheter pulmonary valve replacement (TPVR). Coronary compression is a serious complication of TPVR, but the value of preprocedural CTAs to assess CC risk is largely unexplored. In all, 586 patients underwent TPVR between January 2009 and July 2018. Adults with a pre-TPVR CTA and children with a CTA performed less than one year prior to TPVR were included. Patients with poor CTA image quality or with aborted cases due to reasons other than CC were excluded. Sixty-six patients were finally included. Cardiac anatomy was assessed via multiplanar reconstruction of CTAs. Coronary compression occurred in 9 (14%) of the 66 patients who underwent TPVR. Most CC cases (seven of nine) occurred in patients with conduits. Proximity of the right ventricular outflow tract (RVOT) landing zone to the coronary arteries and to the chest wall was a significant risk factor for compression (P < .001 and P = .019, respectively). Compression risk increased significantly if patients had an RVOT to coronary artery distance of ≤3 mm (P < .001) and an RVOT to chest wall distance of ≤8 mm (P = .026). Anomalous course of coronary arteries was another significant univariate risk factor (P = .003). Right ventricular outflow tract landing zone distance of ≤3 mm to a coronary artery, landing zone distance of ≤8 mm to the chest wall, and anomalous coronary arteries are associated with increased CC risk. Electrocardiogram gating may not be necessary if coronary arteries are opacified on CTAs. Larger studies are needed to explore and confirm these coronary artery compression risk factors.
3 May 2016 in Catheterization and Cardiovascular Interventions
1 March 2007 in Journal of Biomedical Materials Research Part A
18 March 2025 in Circulation
BACKGROUND: Covered stent correction for a sinus venosus atrial septal defect (SVASD) was first performed in 2009. This innovative approach was initially viewed as experimental and was reserved for highly selected patients with unusual anatomic variants. In 2016, increasing numbers of procedures began to be performed, and in several centers, it is now offered as a standard of care option alongside surgical repair. However, covered stent correction for SVASD is not recognized by regulatory authorities, and in the minds of many pediatric and adult congenital cardiologists and surgeons, the condition is viewed as treatable only by cardiac surgery with cardiopulmonary bypass. METHODS: In April 2023, all centers identified from international conferences, publications, and colleague networks to be undertaking covered stent correction for SVASD were invited to participate in a retrospective audit of their procedures. RESULTS: Data were received on 381 patients from 54 units over a 12-year period with 90% of procedures being performed over the past 5 years. Balloon-expandable stents (8 types) were used in the majority; self-expanding stents (4 types) were used in 4.5%. The commonest stent was the 10-zig covered Cheatham Platinum stent in 62% of cases. In 10 procedures, the stent embolized requiring surgical retrieval and repair of the defect, resulting in technically successful implantation in 371 of 381 (97.4%). Major complications (surgical drainage of tamponade, pacemaker implantation, surgery for pulmonary vein occlusion, and late stent removal) occurred in 5 patients (1.3%). Repeat catheterization to correct residual leaks was required in 7 patients (1.8%). Thus, 359 of 381 patients (94.2%) had successful correction without major complications or additional catheter interventions. CONCLUSIONS: This article details the exponential uptake of covered stent correction for SVASD during the past 5 years. Cardiopulmonary bypass was avoided in the majority of patients, and major complications were infrequent. Prospective registries with standardized definitions, inclusion criteria, and follow-up and comparative studies with surgery are now required to help support the extension of covered stent correction as an alternative standard-of-care option for patients with an SVASD.