R. Scott Semken

R. Scott Semken

Auto-generated profile, based on publicly available information

R. Scott Semken

School of Energy Systems, Lappeenranta-Lahti University of Technology, Lappeenranta, Finland

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in Ultrasonics
Verified
Journal Article
Closed access
MMMojtaba Mobaraki
Mojtaba Mobaraki
RSR. Scott Semken
R. Scott Semken
Aki M. MikkolaAki M. Mikkola
Aki M. Mikkola
JPJuha Pyrhönen
Juha Pyrhönen

1 September 2012
Verified
Conference Paper
Closed access
MPM. Polikarpova
M. Polikarpova
PRP. Roytta
P. Roytta
JAJ. Alexandrova
J. Alexandrova
SSS. Semken
S. Semken
JNJ. Nerg
J. Nerg
JPJ. Pyrhonen
J. Pyrhonen
The power of wind turbine is steadily increasing and nowadays machine powers up to 10-20 MW and their possible realizations are discussed. At the moment wind turbines are available up to 8 MW powers. The biggest generators are planned to be installed in offshore applications. More powerful and reliable generators must be designed to be used together with them. Therefore, direct drives are considered. The development of compact high-power direct drive wind turbine generators necessitates design of more effective cooling system to ensure their safe operation. The focus of this paper is in the steady-state thermal analysis of 8 MW DD PMS generator with direct water cooling of the stator winding based on Lumped-Parameter Network (LPN) and Finite Element Analysis (FEA). Thermal design of the generator based Computational Fluid Dynamics (CFD) is also presented here to evaluate the influence of passive air cooling on the rotor.

1 September 2015 in IET Renewable Power Generation
Verified
Journal Article
Open access
PDF file
RSR. Scott Semken
R. Scott Semken
CNCharles Nutakor
Charles Nutakor
Aki M. MikkolaAki M. Mikkola
Aki M. Mikkola
YAYulia Alexandrova
Yulia Alexandrova
A concept has been developed for a novel lightweight wheel structure intended for rotor and stator use in direct‐drive wind turbine generators. It uses a slanted spoke and rim architecture to provide maximum static structural performance with minimum weight. A unique attribute of the structure is its use of layered sheet steel elements to form the spokes and rim. Friction between layers establishes structural integrity. The interaction between layers and the resulting increase in damping normal to the stack offers improved dynamic performance. A static structural analysis of a full‐scale stator wheel structure for an 8 MW permanent magnet machine demonstrates the structural effectiveness of the architecture. To understand vibration characteristics of the lightweight wheel structure, a quarter‐scale prototype was built and an experimental modal analysis was carried out to measure actual radial vibration responses. This data was used to verify a numerical model, and there was good agreement between measured and predicted behaviours. Finally, a modal analysis was carried out for the full‐scale stator wheel structure. The dynamic performance of the wheel is acceptable for the stator of the 8 MW direct‐drive permanent magnet synchronous generator embodiment.

27 May 2024 in Sensors
Verified
Journal Article
Open access
PDF file
MMMojtaba Mohammadalizadeh
Mojtaba Mohammadalizadeh
SJSuraj Jaiswal
Suraj Jaiswal
SSScott Semken
Scott Semken
Aki M. MikkolaAki M. Mikkola
Aki M. Mikkola
Medieval combat sport is a form of mixed martial art in which combatants engage in fighting using offensive and defensive equipment while dressed in full armor. The sport is considered extremely taxing, making it nearly impossible to maintain the same level of performance. However, this form of sport has not been thoroughly analyzed, and its impact on human physical response is largely unknown. To address this gap, the study reported here aimed to introduce and test a procedure for analyzing human physical responses within the framework of the sport. To accomplish this, two experienced combatants were asked to engage in a series of strikes, performed in the form of a set duel simulating a professional fight competition. The kinematic aspect of the procedure was examined using motion analysis with the help of an IMU suit, while the physiological aspect was evaluated based on blood lactate levels and heart rate measurements. Furthermore, an ergometer test conducted in a laboratory setting aimed to determine the lactate threshold. The duel results showed noticeable decreases in the kinematic aspects of the strikes, such as the velocity of impact, and a dramatic rise in physiological aspects, such as heart rate and blood lactate levels. During the duel sets, the blood lactate surpassed the threshold level, and at the end, the heart rate exceeded the maximum age-related level. Practicing medieval combat sport has been shown to impose an extreme physical load on the bodies of combatants, noticeably affecting their performance levels.

19 December 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SWSachintha Alwis Weerasinghe
Sachintha Alwis Weerasinghe
AKAdam Kłodowski
Adam Kłodowski
RSR Scott Semken
R Scott Semken
GOGrzegorz Orzechowski
Grzegorz Orzechowski
Aki M. MikkolaAki M. Mikkola
Aki M. Mikkola
Additive manufacturing provides an efficient method to rapidly develop prototypes utilizing TPU, which is flexible, and Nylon (PA12), which is known for strength and chemical resistance. Five structural adhesives to bond, without plasma/flame pretreatments, flexible FDM TPU to rigid PBF PA12 were benchmarked using the ASTM D903 (180° peel), D2095 (butt-joint tensile), and D3163/D3164 (lap-shear) standards. The adhesives tested were Loctite HY4070, Permatex Plastic Welder, Mannol 9904, Loctite 401 with 770 primer, and 3M DP8010. Across five samples per test, Loctite 401 + 770 achieved the highest mean strengths with low scatter (COV ≤ 15%) in peel (2.6 N/mm), shear (3.0 MPa), and tensile (2.7 MPa) testing. Occasional adherend-side failures in shear suggested joint strengths approaching that of the substrate. The performances of HY4070 and Permatex were acceptable but fell below that of the Loctite 401 + 770. DP8010 and Mannol underperformed, especially in peel and tensile testing. Stress–displacement curves and failure-surface images suggest these adhesives predominantly experienced cohesive failures. Adhesive TPU-PA12 bonding using Loctite 401 with 770 primer is a robust, simple, and fast assembly approach when the presence of thin bond lines is acceptable. We minimize variability through defined process controls and, for durability-critical products, recommend next-stage tests: aging, impact, UV, and fatigue.

9 March 2025
Verified
Book Chapter
Closed access
PDF file
SSSami Suuronen
Sami Suuronen
RERoope Eskola
Roope Eskola
MSMinna Saunila
Minna Saunila
AKAntero Kutvonen
Antero Kutvonen
Emil KurvinenEmil Kurvinen
Emil Kurvinen
Aki M. MikkolaAki M. Mikkola
Aki M. Mikkola