Miniaturized high-sensitivity atomic magnetometers play a crucial role in biomagnetic measurements. The utilization of multipass cells enhances the sensitivity of atomic magnetometers. This study explores the benefits of employing a multipass cell in spin-exchange relaxation-free (SERF) atomic magnetometers through theoretical and experimental analysis. A signal-to-noise ratio (SNR) model was established by accounting for the optimal detuning frequency of the probe light and low-frequency 1/f noise. This enabled the optimal number of probe light passes through the vapor cell to be determined. Additionally, compact and symmetric reflective optical paths were designed to mitigate polarization gradients in atomic magnetometers with high atomic number density. Experimental results confirmed that the magnetic field sensitivity of the triple-pass configuration (1.8 fT/Hz $^{1/2}$ ) was 1.89 times that of the single-pass configuration (3.4 fT/Hz $^{1/2}$ ), consistent with the theoretical analysis. This study provides valuable theoretical guidance for analyzing the SNR performance of SERF atomic magnetometers and demonstrates the potential of multipass cells in enhancing their magnetic field sensitivity. The utilization of multipass cells presents a viable approach toward the realization of highly sensitive and portable miniaturized SERF atomic magnetometers.
12 June 2024 in IEEE Transactions on Instrumentation and Measurement
Uniform magnetic field coils have typically served as important devices of concern in various scientific research and application fields. However, due to the insufficient proportion of uniform areas and the presence of stray magnetic fields, conven-tional coil systems fail to meet the high-precision magnetic field distribution requirements of various applications. Therefore, this study proposes a distributed Taylor expansion method based on Taylor series convergence analysis within intervals, to solve the divergence problem associated with conventional coil design and increase the effective magnetic field working area. In addition, through the creation and screening of characteristic functions, the orthogonality and attenuation of the generated magnetic field are comprehensively improved without changing the basic structure, which is beneficial to solving the common crosstalk and coupling problems caused by stray magnetic fields. The relevant magnetic field characteristics were verified through simulations and ex-periments, demonstrating that the designed square-coil system can achieve significantly increased large uniform area with high orthogonality and self-shielding feature evaluated by suitable characteristic functions established. Thus, the proposed method comprehensively improves coil performance and has strong ap-plication advantages and potential.
1 December 2021 in Journal of Natural Gas Geoscience