Dmitri Yarekha

Dmitri Yarekha

Auto-generated profile, based on publicly available information

Dmitri Yarekha

IEMN, Cité Scientifique - Avenue Poincaré - CS 60069, Villeneuve-d'Ascq, Hauts-de-France, 59652, FRANCE

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2007 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
DVD. Vignaud
D. Vignaud
DYD. A. Yarekha
D. A. Yarekha
JLJ. F. Lampin
J. F. Lampin
MZM. Zaknoune
M. Zaknoune
SGS. Godey
S. Godey
FMF. Mollot
F. Mollot
The electron lifetime has been measured by time-resolved differential transmission experiments in heavily carbon-doped p -type InGaAs and GaAsSb, grown lattice matched on InP by molecular beam epitaxy. It is found inversely proportional to the square of the doping in both alloys, a result typical of Auger recombination dominated processes. It is shown that the electron lifetime is almost twice larger in GaAsSb than in InGaAs for large p -type doping, thus confirming that GaAsSb is a strong contender for the base material of double heterostructure bipolar transistors on InP.

15 July 2024 in Nanotechnology
Verified
Journal Article
Closed access
CBClément Barbot
Clément Barbot
CRClaire Rondeau-Body
Claire Rondeau-Body
CCChristophe Coinon
Christophe Coinon
YDYves Deblock
Yves Deblock
PTPascal Tilmant
Pascal Tilmant
BGBruno Grandidier
Bruno Grandidier
Increasing quantum confinement in semiconductor quantum dot (QD) systems is essential to perform robust simulations of many-body physics. By combining molecular beam epitaxy and lithographic techniques, we developed an approach consisting of a twofold selective area growth to build QD chains. Starting from 15 nm-thick and 65 nm-wide in-plane In0.53Ga0.47As nanowires on InP substrates, linear arrays of In0.53Ga0.47As QDs were grown on top, with tunable lengths and separations. Kelvin probe force microscopy performed at room temperature revealed a change of quantum confinement in chains with decreasing QD sizes, which was further emphasized by the spectral shift of quantum levels resolved in the conduction band with low temperature scanning tunneling spectroscopy. This approach, which allows the controlled formation of 25 nm-thick QDs with a minimum length and separation of 30 nm and 22 nm respectively, is suitable for the construction of scalable fermionic quantum lattices.

21 June 2021 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
PDF file
TLThomas Lerond
Thomas Lerond
DYDmitri Yarekha
Dmitri Yarekha
VAVanessa Avramovic
Vanessa Avramovic
TMThierry Mélin
Thierry Mélin
SASteve Arscott
Steve Arscott
We demonstrate a straightforward surface micromachining process for the rapid prototyping of thin ‘chip-edge’ silicon microcantilevers protruding from the edge of a silicon-on-insulator (SOI) chip. The process uses a single photolithographic mask—with xenon difluoride used to both pattern the silicon microcantilevers and release them by etching part of the underlying silicon wafer. During the release step, the silicon microcantilevers are protected from the xenon difluoride by a combination of photoresist and buried silicon dioxide. The use of common microfabrication materials (SOI and positive photoresist) and chemicals (buffered hydrofluoric acid and xenon difluoride), along with a maximum process temperature of 100 °C, makes for a generic, soft micromachining process which is—in principle—compatible with preserving the integrity of any pre-patterned circuitry present on the silicon microcantilever top surface. Doppler vibrometry measurements of the silicon microcantilevers reveal a well-defined resonant frequency and a quality factor comparable with that of similar silicon microcantilevers fabricated using other means. Our enabling technological process allows the rapid prototyping of chip-edge silicon microcantilevers—potentially integrating sensitive circuitry for novel probe technologies—by avoiding the relatively cumbersome, expensive, and potentially circuit-damaging front-to-back processing/deep etching combination.

30 September 2023 in Russian Journal of Biomechanics
Verified
Journal Article
Closed access
PUPavlov First Saint Petersburg State Medical University
Pavlov First Saint Petersburg State Medical University
VTVladimir Trezubov
Vladimir Trezubov
MMMaxim Mishnev
Maxim Mishnev
YUYaroslav-the-Wise Novgorod State University
Yaroslav-the-Wise Novgorod State University
YPYuri Parshin
Yuri Parshin
DYDenis Yarekha
Denis Yarekha
The world continues to study the biomechanics of implant dentures and their artifi-cial supports. At the same time, different attitudes to the inclined position of distal im-plants in the bone and their bilateral (mesial and distal) loading were noted. The lack of a unified view of the problem under consideration set us the goal to study in the experi-ment the distribution of stresses in the peri-implant bone in vertical (sheer) and inclined implants with the absence or presence of a distally located prosthesis body of various lengths with one-sided support on these artificial supports. For the experiment, we used mathematical modeling by the finite element method. It was used to study the distribution and magnitude of elastic stresses in the peri-implant bone. As a geometric model, a model of the upper jaw with an implant prosthesis installed on it, based on 4 implants, was used. It should be noted that the increase in stress in the material of the prosthesis and compact bone was not critical and was much less than the ultimate strength of these media when the distal implant was tilted with the presence of a dorsal body with one-sided support on the distal implant. As for the spongy bone, the stresses in it showed no dependence on the position of the implant as a whole and slightly increased with an increase in the mesiodistal length of the dorsal body of the prosthesis with one-sided support. Thus, mathematical modeling by the finite element method showed the uncritical distribution of elastic stresses in the prosthesis, distal im-plant, compact and cancellous bone

30 September 2023 in Российский журнал биомеханики
Verified
Journal Article
Closed access
ПППервый Санкт-Петербургский Государственный Медицинский Университет Имени Академика И.п. Павлова
Первый Санкт-Петербургский Государственный Медицинский Университет Имени Академика И.п. Павлова
ВТВладимир Трезубов
Владимир Трезубов
МММаксим Мишнев
Максим Мишнев
НМНовгородский Государственный Университет Им. Ярослава Мудрого
Новгородский Государственный Университет Им. Ярослава Мудрого
ЮПЮрий Паршин
Юрий Паршин
ДЯДенис Яреха
Денис Яреха
В мире продолжается изучение биомеханики имплантационных зубных протезов и их искусственных опор. При этом отмечено различное отношение к наклонному положению дистальных имплантатов в кости и их двусторонней (мезиальной и дистальной) нагрузке. Отсутствие единого взгляда на рассматриваемую проблему определило цель исследования изучить в эксперименте распределение напряжений в периимплантатной кости у вертикальных (отвесных) и наклоненных имплантатов с отсутствием или наличием дистально расположенного тела протеза различной протяжённости с односторонней опорой на этих искусственных опорах. Для эксперимента нами использовано математическое моделирование методом конечных элементов. С его помощью изучались распределения и величины упругих напряжений в периимплантатной кости. В качестве геометрической модели использована модель верхней челюсти с установленным на ней имплантационным протезом, опирающимся на 4 имплантата. Следует отметить, что увеличение напряжения в материале протеза и компактной кости не являлось критичным и было гораздо меньше пределов прочности указанных сред при наклоне дистального имплантата с наличием дорзального тела с односторонней опорой на дистальном имплантате. Что же касается губчатой кости, то напряжения в ней в целом не показали зависимости положения имплантата и слабо возрастали при увеличении мезиодистальной протяженности дорзального тела протеза с односторонней опорой. Таким образом, математическое моделирование методом конечных элементов показало некритичность распределения упругих напряжений в протезе, дистальном имплантате, компактной и губчатой кости при различной конфигурации дистальных отделов протеза.