Chandan Kumar

Chandan Kumar

Auto-generated profile, based on publicly available information

Chandan Kumar

Department of Electronics and Communication Engineering, Supaul College of Engineering, Supaul, India

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 December 2015 in IEEE Transactions on Nanotechnology
Verified
Journal Article
Closed access
GRGopal Rawat
Gopal Rawat
DSDivya Somvanshi
Divya Somvanshi
HKHemant Kumar
Hemant Kumar
YKYogesh Kumar
Yogesh Kumar
CKChandan Kumar
Chandan Kumar
Satyabrata JitSatyabrata Jit
Satyabrata Jit
This paper reports a comparative study of the ultraviolet (UV) detection properties of n-TiO 2 /p-Si heterojunction devices fabricated using two different deposition techniques namely the electron-beam evaporation (EBE) and sol-gel (SG) methods. A systematic study has also been carried out to investigate the structural, electrical, and optical properties of the as deposited TiO 2 thin films on p-Si substrates by the EBE and SG methods. The electrical parameters of both the n-TiO 2 /p-Si heterojunction photodiodes have been measured and compared under dark and UV illumination conditions. The SG based n-TiO 2 /p-Si heterojunction photodiodes are observed with an excellent contrast ratio of ~83911 at -5.2 V bias voltage, which is ~6445 times higher than the EBE-based device. The measured responsivities of the EBE and SG based devices are ~0.69 and ~1.25 A/W at a bias voltage of -10 V (P opt = 650 μW and λ = 365 nm), respectively. Thus, the n-TiO 2 /p-Si heterojunction diodes with SG derived TiO 2 films are considered to be a better choice over the EBE-based n-TiO 2 /p-Si diodes for UV detection applications.

18 February 2020 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
CKChandan Kumar
Chandan Kumar
BKBhoopendra Kumar Kushwaha
Bhoopendra Kumar Kushwaha
AKAmit Kumar
Amit Kumar
DJDeepak Kumar Jarwal
Deepak Kumar Jarwal
RURishibrind Kumar Upadhyay
Rishibrind Kumar Upadhyay
Satyabrata JitSatyabrata Jit
Satyabrata Jit
Ultraviolet (UV) detection properties of undoped ZnO and Al-doped ZnO (AZO) based interdigitated metal-semiconductor-metal (MSM) structure are investigated in this paper. High quality of fibrous Al-doped ZnO thin films with enhanced conductivity and optical response with controlled doping of Al are synthesized using low-cost sol-gel method. The surface morphology and absorption properties of the films have been investigated. The responsivity and detectivity characteristics of both the devices are compared over 300-700 nm wavelengths. The Al-doped ZnO based Ag/AZO/Ag MSM structure show the maximum responsivity and detectivity of ~5.63 A/W and ~1.8×1012 cmHz1/2W-1 while the respective values for the Ag/undoped-ZnO/Ag photodetector are ~3.65 A/W and ~1.3×1012 cmHz1/2W-1 at 365 nm and 34 μW/cm2 incident UV intensity. The proposed AZO based MSM photodetector has smaller rise time (~30 s) than that (~35 s) of the undoped ZnO based MSM photodetector. However, the AZO based device shows slightly poor spectrum selectivity over the undoped ZnO based device.

2 January 2017 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
YKYogesh Kumar
Yogesh Kumar
HKHemant Kumar
Hemant Kumar
GRGopal Rawat
Gopal Rawat
CKChandan Kumar
Chandan Kumar
ASAnand Sharma
Anand Sharma
Satyabrata JitSatyabrata Jit
Satyabrata Jit
This letter reports (possibly for first time) the synthesis, fabrication, and characterization of a solution processed colloidal ZnO quantum dots (QDs) photoconductor-based spectrum selective ultraviolet (UV) photodetector on low-cost glass substrates without using any additional absorption tuning layer. The QD nature of colloidal ZnO was confirmed by transmission electron microscopy measurements in terms of average particle size (~2.53nm) smaller than Bohr's radius (~2.87 nm for ZnO). Furthermore, annealing at the ambient environment showed a shift in the bandgap from 3.231 to 3.136 eV of the ZnO QDs corresponding to the change in the annealing temperature from 450 °C and 600 °C. The responsivity characteristics showed a spectrum selective UV photoconductor nature with a full width half maximum of ~49 nm and the maximum responsivity of ~15.04 A/W at 2 V bias voltage and ~360-nm operating wavelength. The response time and recovery time were measured as 7.2 and ~18.5 s, respectively. The responsivity is believed to be the best among the reported ZnO QDs-based spectrum selective detectors.

1 September 2017 in Organic Electronics
Verified
Journal Article
Closed access
CKChandan Kumar
Chandan Kumar
GRGopal Rawat
Gopal Rawat
HKHemant Kumar
Hemant Kumar
YKYogesh Kumar
Yogesh Kumar
RPRajiv Prakash
Rajiv Prakash
Satyabrata JitSatyabrata Jit
Satyabrata Jit

14 January 2019 in RSC Advances
Verified
Journal Article
Open access
PDF file
AMAshwini Kumar Mishra
Ashwini Kumar Mishra
BMBratindranath Mukherjee
Bratindranath Mukherjee
AKAmit Kumar
Amit Kumar
DJDeepak Kumar Jarwal
Deepak Kumar Jarwal
SRSmrity Ratan
Smrity Ratan
Satyabrata JitSatyabrata Jit
Satyabrata Jit
This paper describes a low-cost facile method to construct gold (Au) nanoparticles (NPs) modified copper oxide (CuO) nanowires (NWs) electrode on copper foil for the detection of glucose. Copper foil has been converted to aligned CuO NWs arrays by sequential formation of Cu(OH)2 followed by heat treatment induced phase transformation to CuO. Au NPs are deposited on CuO NWs via simple reductive solution chemistry to impart high surface to volume ratio and enhanced catalytic activity of the resulting electrode. Structure, microstructure and morphology of Cu, Cu(OH)2 NWs, CuO NWs, and Au NPs modified CuO NWs are investigated by X-ray diffraction (XRD) and scanning electron microscopy (SEM). The homogeneous distribution of Au NPs (average diameter ∼12 nm) on CuO NWs (average diameter 100 nm and aspect ratio ∼20) is confirmed by high-resolution transmission electron microscopy (HRTEM), scanning transmission electron microscopy (STEM) and elemental mapping. This CuO based glucose detection method gives the highest sensitivity along with the maximum linearity range. This non-enzymatic glucose sensor based on Au modified CuO NWs electrode gives broad linearity range from 0.5 μM to 5.9 mM. The sensor exhibits sensitivity of 4398.8 μA mM−1 cm−2, lower detection limit of 0.5 μM, and very fast response time of ∼5 s. Properties of the proposed glucose sensor are also investigated in human blood and it is found that the sensor is highly accurate and reliable. In addition, higher sensitivity and lower detection limit confirm that this device is suitable for invasive detection in saliva and urine.

1 July 2017 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
PSPraveen Kumar Sahu
Praveen Kumar Sahu
MPManish Pandey
Manish Pandey
CKChandan Kumar
Chandan Kumar
SPShyam S. Pandey
Shyam S. Pandey
WTWataru Takashima
Wataru Takashima
RPRajiv Prakash
Rajiv Prakash