Bailey Reid

Bailey Reid

Auto-generated profile, based on publicly available information

Bailey Reid

Department of Civil & Resource Engineering

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2026 in ChemRxiv
Verified
Preprint
Open access
SMSean A. MacIsaac
Sean A. MacIsaac
COCarolina Ontiveros
Carolina Ontiveros
JBJessica L. Bennett
Jessica L. Bennett
BRBailey Reid
Bailey Reid
EOEsther Osei-Ampong
Esther Osei-Ampong
ASAmina K. Stoddart
Amina K. Stoddart
Removal of organic loading in wastewater effluent is a priority for treatment facilities to ensure discharge water adheres to local regulations and is safe for the environment. This study investigated the removal of bulk organic matter (as measured by biochemical and carbonaceous biochemical oxygen demand, BOD5 and cBOD5, respectively) from municipal wastewater effluent using 275-280 nm UV LED irradiation under bench-scale and full-scale conditions. Bench-scale removal was evaluated using both collimated beam and flow through UV LED reactors (275 nm) at fluences between 250 - 5000 mJ cm-2 with and without chemical oxidant addition (chlorine) for primary and secondary effluent matrices. Treatment efficacy for the secondary effluent source was also investigated using a full-scale flow-through 280 nm UV LED reactor at a fluence of approximately 148 mJ cm-2 and a flow of 545 m3 day-1. This work determined that UV C LED irradiation can reduce effluent BOD in municipal wastewater matrices (by up to 52%) at both the bench- and full-scale. Mechanistically, the fluorescence profile of UV-exposed samples exhibited a shift in the humic index suggesting that lower weight, protein-like organic compounds were the primary target of the UV C process. This work demonstrates that UV C LED technologies can be a useful tool for water utilities that require additional BOD removal.

13 June 2024 in medRxiv
Verified
Preprint
Open access
PDF file
SMSean A MacIsaac
Sean A MacIsaac
BRBailey Reid
Bailey Reid
COCarolina Ontiveros
Carolina Ontiveros
KLKarl Linden
Karl Linden
ASAmina K Stoddart
Amina K Stoddart
GGGraham A Gagnon
Graham A Gagnon
The world’s first full-scale, 280 nm UV LED reactor for wastewater disinfection was tested at flows of 545 and 817 m 3 day -1 . The system achieved a >3 average log reduction of total coliform at 545 m 3 day -1 and the 817 m 3 day -1 flow rate achieved over a >2.5 average log reduction for all operational conditions. The delivered fluence of the full-scale system ranged from 28-148 mJ cm -2 and aligns with a UV auditing study that was conducted prior to the installation of the wastewater reactor. These results benchmark the performance that can be achieved by UV LED disinfection and further connect bench-scale disinfection results with full-scale performance. The approach established in this manuscript provides a novel tool for utilities when considering emerging UV disinfection technologies. In summary, this study establishes that UV LEDs are an effective wastewater disinfectant at-scale and are comparable to conventional low-pressure UV systems. This is the first instance where the efficacy of UV LEDs for municipal wastewater disinfection has been demonstrated using a large-scale installation at a functioning wastewater facility. Graphical

27 April 2026 in ChemRxiv
Verified
Preprint
Open access
SMSean A. MacIsaac
Sean A. MacIsaac
COCarolina Ontiveros
Carolina Ontiveros
JBJessica L. Bennett
Jessica L. Bennett
BRBailey Reid
Bailey Reid
EOEsther Osei-Ampong
Esther Osei-Ampong
ASAmina K. Stoddart
Amina K. Stoddart
Removal of organic loading in wastewater effluent is a priority for treatment facilities to ensure discharge water adheres to local regulations and is safe for the environment. This study investigated the removal of bulk organic matter (as measured by biochemical and carbonaceous biochemical oxygen demand, BOD5 and cBOD5, respectively) from municipal wastewater effluent using 275-280 nm UV LED irradiation under bench-scale and full-scale conditions. Bench-scale removal was evaluated using both collimated beam and flow through UV LED reactors (275 nm) at fluences between 250 - 5000 mJ cm-2 with and without chemical oxidant addition (chlorine) for primary and secondary effluent matrices. Treatment efficacy for the secondary effluent source was also investigated using a full-scale flow-through 280 nm UV LED reactor at a fluence of approximately 148 mJ cm-2 and a flow of 545 m3 day-1. This work determined that UV C LED irradiation can reduce effluent BOD in municipal wastewater matrices (by up to 52%) at both the bench- and full-scale. Mechanistically, the fluorescence profile of UV-exposed samples exhibited a shift in the humic index suggesting that lower weight, protein-like organic compounds were the primary target of the UV C process. This work demonstrates that UV C LED technologies can be a useful tool for water utilities that require additional BOD removal.

31 August 2026 in ChemRxiv
Verified
Preprint
Open access
BRBailey Reid
Bailey Reid
SMSean A. MacIsaac
Sean A. MacIsaac
SOSarah Organ
Sarah Organ
COCarolina Ontiveros
Carolina Ontiveros
GGGraham A. Gagnon
Graham A. Gagnon
ASAmina K. Stoddart
Amina K. Stoddart
Wastewater treatment facilities (WWTFs) are currently facing multitudes of challenges including incline in population, climate change driven challenges and stringent regulation limits. Ultraviolet light emitting diodes (UV LEDs) are becoming an attractive disinfection system that has demonstrated powerful inactivation capabilities with modular system design, becoming a useful alternative treatment to conventional UV systems. A UVLED full-scale reactor was assessed for real municipal wastewater at the highest reported flow rates with a max flowrate of 2,725 m3 day-1. The reactor showed results ranging between 0.68 and 3 log reduction values for E. coli inactivation across the various high flowrates tested. The results accumulated throughout the study periods was further used to characterize the true capacity of the full-scale UV LED flow through reactor and demonstrated prediction capabilities through a sampling methodology. Furthermore, statistical analysis conducted between the two full-scale systems at the study site predicted probabilities of 66.5 and 25.6% of the UV LED system and conventional UV system for achieving 3 LRVs based on the data available throughout the study. Overall, the results provided by this study and the previous study by MacIsaac et al. (2024) demonstrated the performance and pluralist treatment variability of UV LED systems for wastewater treatment.