Drinking water samples were collected from the water source, water delivery truck, domestic water storage tanks, and at the point of use in a decentralized drinking water system in Pond Inlet, Nunavut, a predominantly Inuit community in Canada's Arctic region.
During the COVID-19 pandemic, N95 filtering facepiece respirators (FFRs) were recommended to protect healthcare workers when providing care to infected patients. Despite their single-use disposable nature, the need to disinfect and repurpose FFRs is paramount during this global emergency. The objectives of this study were to (1) determine if UV treatment has an observable impact on respirator integrity; (2) test the impact of UV treatment on N95 FFR user fit; and (3) test the impact of UV treatment on FFR integrity. Ultraviolet (UV) disinfection was assessed in maintaining N95 FFR integrity. Two models of FFRs were exposed to UV fluences ranging from 0 to 10,000 mJ cm−2 per side and subsequently tested for fit, respirator integrity, and airflow. Inspection of N95 FFRs before and after UV treatment via microscopy methods showed no observable or tactile abnormalities in the integrity of respirator material or straps. Tensile loading tests on UV-treated and untreated respirator straps also demonstrated no impact on breaking strength. Standardized fit test methods showed no compromise in user fit following UV treatment. Evaluation of particle penetration and airflow through N95 FFRs showed no impact on integrity, and average filtration efficiency did not fall below 95% for any of the respirator types or fluence levels. This work provides evidence that UV disinfection does not compromise N95 FFR integrity at UV fluences up to 10,000 mJ cm−2. UV disinfection is a viable treatment option to support healthcare professionals in their strategy against the spread of COVID-19.
Immersive ultraviolet disinfection provides a chemical-free technology for safer textiles, surfaces, and public spaces by inactivating communicable pathogens. This study examined immersive UV disinfection, using a disinfection cabinet, of E. coli and MS2 that was inoculated on white cotton T-shirts. The impact that porous materials have on UV disinfection is poorly understood with the majority of previous surface disinfection research focusing on hard, smooth surfaces. Several approaches were used in this study to characterize the light dynamics within the disinfection cabinet including colorimetric dosimetry coupons, biodosimetry, and spectroradiometry. Micro and macro geometry of porous surfaces are important factors to consider when using immersive UV technologies. The geometry of the cabinet impacted the distribution of emitted UV light within the disinfection cabinet and the physical properties of a porous material, such as the woven pattern of cotton, both contribute to UV disinfection efficiency. This work identified that light distribution is crucial for immersive UV technologies as the delivered fluence was highly variable within the disinfection cabinet and resulted in a difference of several logs of reduction for adjacent areas of T-shirt samples. Other inoculated areas achieved upwards of 1-log reductions values for MS2 and upwards of 2-log reductions for E. coli.
24 June 2020 in Environmental Science: Water Research & Technology
A commercially-available UV surface disinfection system used for hospital room disinfection was characterized for use as a UV-inactivation system for N95 filtering facepiece respirator (FFR) respirators. The output of light was initially characterized and assessed for its ability to penetrate through the individual N95 respirator layers. Following characterization, disinfection performance was tested using a range of model pathogens. In a series of experiments, coupons of respirator material were inoculated with Escherichia coli, Staphylococcus aureus, Geobacillus stearothermophilus spores, Bacillus cereus, Pseudomonas aeruginosa, and influenza A virus. Inoculated coupons were then treated with UV light from a low-pressure UV disinfection system during specific treatment times. Microbial enumeration was performed pre- and post-UV treatment. It was found that respirator coupons inoculated with E. coli, influenza A, P. aeruginosa, B. cereus and G. stearothermophilus resulted in below detection counts when exposed to UV fluences between 410 to 2700 mJ cm−2. In addition, UV light was unable to sufficiently penetrate all layers of respirator material, highlighting the importance of flipping respirators when exposing them to UV light. This work suggests that with further validation, UV light will be a promising touchless treatment option for frontline professionals who need to repurpose N95 respirators for subsequent use.
Removal of organic loading in wastewater effluent is a priority for treatment facilities to ensure discharge water adheres to local regulations and is safe for the environment. This study investigated the removal of bulk organic matter (as measured by biochemical and carbonaceous biochemical oxygen demand, BOD5 and cBOD5, respectively) from municipal wastewater effluent using 275-280 nm UV LED irradiation under bench-scale and full-scale conditions. Bench-scale removal was evaluated using both collimated beam and flow through UV LED reactors (275 nm) at fluences between 250 - 5000 mJ cm-2 with and without chemical oxidant addition (chlorine) for primary and secondary effluent matrices. Treatment efficacy for the secondary effluent source was also investigated using a full-scale flow-through 280 nm UV LED reactor at a fluence of approximately 148 mJ cm-2 and a flow of 545 m3 day-1. This work determined that UV C LED irradiation can reduce effluent BOD in municipal wastewater matrices (by up to 52%) at both the bench- and full-scale. Mechanistically, the fluorescence profile of UV-exposed samples exhibited a shift in the humic index suggesting that lower weight, protein-like organic compounds were the primary target of the UV C process. This work demonstrates that UV C LED technologies can be a useful tool for water utilities that require additional BOD removal.
The world’s first full-scale, 280 nm UV LED reactor for wastewater disinfection was tested at flows of 545 and 817 m 3 day -1 . The system achieved a >3 average log reduction of total coliform at 545 m 3 day -1 and the 817 m 3 day -1 flow rate achieved over a >2.5 average log reduction for all operational conditions. The delivered fluence of the full-scale system ranged from 28-148 mJ cm -2 and aligns with a UV auditing study that was conducted prior to the installation of the wastewater reactor. These results benchmark the performance that can be achieved by UV LED disinfection and further connect bench-scale disinfection results with full-scale performance. The approach established in this manuscript provides a novel tool for utilities when considering emerging UV disinfection technologies. In summary, this study establishes that UV LEDs are an effective wastewater disinfectant at-scale and are comparable to conventional low-pressure UV systems. This is the first instance where the efficacy of UV LEDs for municipal wastewater disinfection has been demonstrated using a large-scale installation at a functioning wastewater facility. Graphical