13 November 2009 in IEEE Transactions on Industrial Electronics
A new design approach achieving very high conversion efficiency in low-voltage high-power isolated boost dc-dc converters is presented. The transformer eddy-current and proximity effects are analyzed, demonstrating that an extensive interleaving of primary and secondary windings is needed to avoid high winding losses. The analysis of transformer leakage inductance reveals that extremely low leakage inductance can be achieved, allowing stored energy to be dissipated. Power MOSFETs fully rated for repetitive avalanches allow primary-side voltage clamp circuits to be eliminated. The oversizing of the primary-switch voltage rating can thus be avoided, significantly reducing switch-conduction losses. Finally, silicon carbide rectifying diodes allow fast diode turn-off, further reducing losses. Detailed test results from a 1.5-kW full-bridge boost dc-dc converter verify the theoretical analysis and demonstrate very high conversion efficiency. The efficiency at minimum input voltage and maximum power is 96.8%. The maximum efficiency of the proposed converter is 98%.
27 September 2016 in IEEE Transactions on Industrial Electronics
This paper demonstrates the utilization of gallium nitride (GaN) devices to achieve an ultrahigh efficiency in an isolated dc-dc converter. This paper presents the design and implementation of high-efficiency magnetics necessary to realize such an ultrahigh efficiency converter. Synchronous rectification is also implemented to further improve the efficiency. Compared to an equivalent silicon MOSFET, GaN devices have low output charge, very low gate drive losses, and zero reverse recovery losses, this makes GaN devices more suitable for power converters to achieve high efficiency. A complete analytical loss modeling for an isolated full bridge dc-dc converter is discussed in this paper. Furthermore, the experimental demonstration of ultrahigh efficiency in a 2.4-kW isolated GaN converter is presented. Ultrahigh conversion efficiency allows the realization of a very compact dc-dc converter with a very small or no heat sink. The prototype converter has a power density of 7 kW/L and the measured efficiency is above 98.5% over a wide range of output power. The maximum measured efficiency of the converter is 98.8% at 50% of full load.
17 May 2017 in IEEE Transactions on Power Electronics
This paper proposes a comprehensive analytical LCL filter design method for three-phase two-level power factor correction rectifiers (PFCs). The high-frequency converter current ripple generates the high-frequency current harmonics that need to be attenuated with respect to the grid standards. Studying the high-frequency current of each element proposes a noniterative solution for designing an LCL filter. In this paper, the converter current ripple is thoroughly analyzed to generalize the current ripple behavior and find the maximum current ripple for sinusoidal pulse width modulation (PWM) and third-harmonic injection PWM. Consequently, the current ripple is used to accurately determine the required filter capacitance based on the maximum charge of the filter capacitor. To choose the grid-side inductance, two methods are investigated. First method uses the structure of the damping to express the grid-side filter inductance as a function of the converter current ripple. Reducing the power loss in the filter and optimizing the grid-side filter inductance is the main focus of the second method which is achieved by employing line impedance stabilization network (LISN). Accordingly, two LCL filters are designed for a 5 kW silicon-carbide-based three-phase PFC. Various experimental scenarios are performed to verify the filters attenuation and performance.