26 May 2022 in IEEE Solid-State Circuits Letters
Verified
Journal Article
Closed access
WAWoojin Ahn
Woojin Ahn
DKDoohee Kim
Doohee Kim
JPJonghyeok Park
Jonghyeok Park
JPJoeng Hoan Park
Joeng Hoan Park
TLTaeju Lee
Taeju Lee
MJMinkyu Je
Minkyu Je
This letter presents a neural stimulation IC for the 32-channel cochlear implant system. A zoom current DAC (I-DAC), whose full range is reconfigured to fit the interval between the comfort (C) and threshold (T) levels, is introduced for high-resolution stimulation strength control to provide high-fidelity sound perception with minimal hardware overhead. The IC also includes an in-situ neural recording function. The effectiveness of auditory nerve stimulation is validated by monitoring electrically evoked compound action potential (ECAP) in-vivo using a rat model. It is found that the action potential amplitude increases as the stimulation current level becomes larger.

13 November 2024 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
WAWoojin Ahn
Woojin Ahn
KNKim-Hoang Nguyen
Kim-Hoang Nguyen
HLHoseung Lee
Hoseung Lee
KMKyou Sik Min
Kyou Sik Min
Sohmyung HaSohmyung Ha
Sohmyung Ha
MJMinkyu Je
Minkyu Je
This paper presents the design and validation of a stimulation system for cochlear implants, addressing primary challenges in their power management, including variable supply conditions, multi-channel stimulation demands, and the necessity for swift, real-time data handling. The proposed stimulation system employs an adaptive dynamic voltage switching (ADVS) block and a single-inductor multiple-output (SIMO) boost converter to generate and selectively assign optimal voltage levels to each stimulation channel. This strategic selection, governed remotely via an external sound processor and adaptively controlled by a compliance monitoring circuit, facilitates dynamic voltage adjustments within sub-μs, enhancing system responsiveness and energy efficiency. Fabricated in a 180-nm BCD process, the system’s functionality and efficiency have been validated by measurements, showing an enhancement in battery life up to 13.5% which translates into an extra 3.4 hours of operational time. Through the integration of ADVS, the proposed system not only enhances the performance of cochlear implants, but also ensures the adaptability and effectiveness in real-world environments.