This paper presents the design and validation of a stimulation system for cochlear implants, addressing primary challenges in their power management, including variable supply conditions, multi-channel stimulation demands, and the necessity for swift, real-time data handling. The proposed stimulation system employs an adaptive dynamic voltage switching (ADVS) block and a single-inductor multiple-output (SIMO) boost converter to generate and selectively assign optimal voltage levels to each stimulation channel. This strategic selection, governed remotely via an external sound processor and adaptively controlled by a compliance monitoring circuit, facilitates dynamic voltage adjustments within sub-μs, enhancing system responsiveness and energy efficiency. Fabricated in a 180-nm BCD process, the system’s functionality and efficiency have been validated by measurements, showing an enhancement in battery life up to 13.5% which translates into an extra 3.4 hours of operational time. Through the integration of ADVS, the proposed system not only enhances the performance of cochlear implants, but also ensures the adaptability and effectiveness in real-world environments.
17 September 2024 in IEEE Solid-State Circuits Letters
A fully integrated dynamic-voltage-scaling stimulator IC, consisting of a novel reconfigurable supply modulator (RSM) and 12 high-voltage-tolerant channel drivers, for cochlear implants, is presented, utilizing a 180-nm standard CMOS process. The RSM is designed to adaptively generate one of four supply voltage levels ranging from 2.6V to 11.3V, effectively stimulating the cochlea with varying electrode-tissue-interface impedance and stimulus currents while offering improved power efficiency. The channel driver design is miniaturized to support high-channel-count applications within a single IC. Additional excessive current protection is implemented to ensure charge balancing between biphasic stimulating pulses, complementing the electrode-shorting technique.
10 December 2025 in IEEE Open Journal of the Solid-State Circuits Society
This paper presents a neural implant system for prosthetic limbs that enables simultaneous multi-site data transmission via galvanically coupled body-channel communication (GC-BCC) for fine, low-latency control. Ultrasound and RF uplinks typically require multiple-access schemes to avoid collisions across implants. Capacitive BCC can support simultaneous links, but the small, motion-variant return-path capacitance reduces channel gain and undermines robustness. In contrast, GC-BCC forms a closed-loop current path for each transmitter.receiver pair via a dedicated termination, enabling simultaneous uplinks without multiple-access scheme. Implemented in 180-nm CMOS, the system integrates a 16-channel neural recording analog front end, a GC-BCC transceiver, and low-dropout regulators. Through 15-mm porcine tissue, the link sustains a 20-Mbps data rate with a bit-error rate below 1.3×105. Two GC-BCC transceivers operate simultaneously with 100-Ω termination with negligible crosstalk at ≥1.6-cm spacing. The measured energy efficiencies are 20.35 pJ/bit for the transmitter and 467.4 pJ/bit for the receiver.