Chalinee Thanasupsombat

Chalinee Thanasupsombat

Auto-generated profile, based on publicly available information

Chalinee Thanasupsombat

Medical Imaging System Research Team, Assistive Technology and Medical Devices Research Group, National Electronics and Computer Technology Center, Klong Luang, Pathum Thani, Thailand

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 January 2018 in BioMed Research International
Verified
Journal Article
Open access
PDF file
CTChalinee Thanasupsombat
Chalinee Thanasupsombat
STSaowapak S. Thongvigitmanee
Saowapak S. Thongvigitmanee
SASorapong Aootaphao
Sorapong Aootaphao
PTPairash Thajchayapong
Pairash Thajchayapong
The quality of images obtained from cone-beam computed tomography (CBCT) is important in diagnosis and treatment planning for dental and maxillofacial applications. However, X-ray scattering inside a human head is one of the main factors that cause a drop in image quality, especially in the CBCT system with a wide-angle cone-beam X-ray source and a large area detector. In this study, the X-ray scattering distribution within a standard head phantom was estimated using the Monte Carlo method based on Geant4. Due to small variation of low-frequency scattering signals, the scattering signals from the head phantom can be represented as the simple predetermined scattering signals from a patient’s head and subtracted the projection data for scatter reduction. The results showed higher contrast and less cupping artifacts on the reconstructed images of the head phantom and real patients. Furthermore, the same simulated scattering signals can also be applied to process with higher-resolution projection data.

10 April 2026 in Journal of X-Ray Science and Technology
Verified
Journal Article
Closed access
STSaowapak S Thongvigitmanee
Saowapak S Thongvigitmanee
KKKittipong Kasantikul
Kittipong Kasantikul
CTChalinee Thanasupsombat
Chalinee Thanasupsombat
WNWalita Narkbuakaew
Walita Narkbuakaew
AKAtthasak Kiang-Ia
Atthasak Kiang-Ia
PTPairash Thajchayapong
Pairash Thajchayapong
In comparison to conventional medical computed tomography (CT), cone-beam CT (CBCT) has become widely used in dental and maxillofacial applications due to its accurate 3D information, high resolution, minimal radiation dose, and affordable machine cost. In this study, we investigated the image quality and radiation doses of dental CBCT and X-ray machines developed in Thailand. Our in-house reconstruction algorithm including artifact reduction was based on GPU calculations of filtered backprojection and was significantly faster than a CPU-based algorithm. The image quality aspects for CBCT were evaluated in terms of high contrast resolution, gray value uniformity, noise, and geometric accuracy, while image quality assessment for 2D images included high contrast resolution, low contrast levels, and distortion rate. Radiation doses were measured and calculated for the dose-area product (DAP). The technical image quality and radiation dose assessment was compared with those of other commercial extraoral imaging machines. The findings demonstrate that, when compared to other units, the proposed 2D and 3D extraoral imaging systems yielded comparable technical image quality and radiation doses. Based on these results, the Thai-made 2D and 3D extraoral imaging machines appear suitable for further clinical evaluation.

30 May 2018
Verified
Book Chapter
Closed access
PDF file
STSaowapak S. Thongvigitmanee
Saowapak S. Thongvigitmanee
WNWalita Narkbuakaew
Walita Narkbuakaew
SASorapong Aootaphao
Sorapong Aootaphao
CTChalinee Thanasupsombat
Chalinee Thanasupsombat
KWKongyot Wangkaoom
Kongyot Wangkaoom
PTPairash Thajchayapong
Pairash Thajchayapong