Pairash Thajchayapong

Pairash Thajchayapong

Auto-generated profile, based on publicly available information

Pairash Thajchayapong

National Science and Technology Development Agency, Klong Luang, Pathum Thani, Thailand

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 November 2016 in International Journal of Photoenergy
Verified
Journal Article
Open access
PDF file
SKSongkiate Kittisontirak
Songkiate Kittisontirak
ABAekkawat Bupi
Aekkawat Bupi
PCPerawut Chinnavornrungsee
Perawut Chinnavornrungsee
KSKobsak Sriprapha
Kobsak Sriprapha
PTPairash Thajchayapong
Pairash Thajchayapong
WTWisut Titiroongruang
Wisut Titiroongruang
This paper proposes a new concept to improve accuracy of PV forecasting model. The model was implemented by MATLAB/Simulink software using solar irradiance and module temperature as measurement parameters for calculation. The model was developed by single-diode equivalent circuits (5-p model) for simulated PV module power output and compared with other software programs for validation which showed correct PV characteristics. To achieve high accuracy, the model was improved by weight function using one-year measured data. The accuracy of our developed model was verified by comparison with four commercial simulator software programs and the results from real system which were measured and recorded for 1 year. It was found that the model output was in a good agreement with the measured data. This research can be utilized in another area by adjusting the PV equation with weight function of that area.

3 January 2018 in BioMed Research International
Verified
Journal Article
Open access
PDF file
CTChalinee Thanasupsombat
Chalinee Thanasupsombat
STSaowapak S. Thongvigitmanee
Saowapak S. Thongvigitmanee
SASorapong Aootaphao
Sorapong Aootaphao
PTPairash Thajchayapong
Pairash Thajchayapong
The quality of images obtained from cone-beam computed tomography (CBCT) is important in diagnosis and treatment planning for dental and maxillofacial applications. However, X-ray scattering inside a human head is one of the main factors that cause a drop in image quality, especially in the CBCT system with a wide-angle cone-beam X-ray source and a large area detector. In this study, the X-ray scattering distribution within a standard head phantom was estimated using the Monte Carlo method based on Geant4. Due to small variation of low-frequency scattering signals, the scattering signals from the head phantom can be represented as the simple predetermined scattering signals from a patient’s head and subtracted the projection data for scatter reduction. The results showed higher contrast and less cupping artifacts on the reconstructed images of the head phantom and real patients. Furthermore, the same simulated scattering signals can also be applied to process with higher-resolution projection data.

1 January 2021 in BioMed Research International
Verified
Journal Article
Open access
PDF file
UTUdomchai Techavipoo
Udomchai Techavipoo
NSNattawut Sinsuebphon
Nattawut Sinsuebphon
SPSakunrat Prompalit
Sakunrat Prompalit
STSaowapak Thongvigitmanee
Saowapak Thongvigitmanee
WNWalita Narkbuakaew
Walita Narkbuakaew
UCUtairat Chaumrattanakul
Utairat Chaumrattanakul
Background. The National Science and Technology Development Agency (NSTDA) in Thailand researched and prototyped digital radiography systems under the brand name BodiiRay aiming for sustainable development and affordability of medical imaging technology. The image restoration and enhancement were implemented for the systems. Purpose. The image quality of the systems was evaluated using images from phantoms and from healthy volunteers. Methods. The survey phantom images from BodiiRay and other two commercial systems using the exposure settings for the chest, the abdomen, and the extremity were evaluated by three experience observers in terms of the high‐contrast image resolution, the low‐contrast image detectability, and the grayscale differentiation. The volunteer images of the chests, the abdomens, and the extremities from BodiiRay were evaluated by three specialized radiologists based on visual grading on 5‐point scaled questionnaires for the anatomy visibility, the image quality satisfaction, and the diagnosis confidence in using the images. Results. BodiiRay phantom results were similar to those from the commercial systems. The overall performance averaged across the exposure settings showed that BodiiRay was slightly better than Fujifilm FDR Go in the low‐contrast detectability (p = 0.033) and in the grayscale differentiation (p = 0.004). It was also slightly better than Siemens YSIO Max in the high‐contrast resolution (p = 0.018). The images of chest, pelvis, and hand phantoms illustrated comparable visual quality. For volunteer images, the percentage of the images scored ≥4 ranged from 61% to 99%, 23% to 92%, and 96% to 99% for the chest, abdomen, and extremity images, respectively. The average score ranged from 3.63 to 4.46, 3.18 to 4.21, and 4.41 to 4.51 for the chest, abdomen, and extremity images, respectively. Conclusion. The phantom image results showed the comparability of these systems. The clinical evaluation showed BodiiRay images provided sufficient image qualities for digital radiography of these body parts.

10 April 2026 in Journal of X-Ray Science and Technology
Verified
Journal Article
Closed access
STSaowapak S Thongvigitmanee
Saowapak S Thongvigitmanee
KKKittipong Kasantikul
Kittipong Kasantikul
CTChalinee Thanasupsombat
Chalinee Thanasupsombat
WNWalita Narkbuakaew
Walita Narkbuakaew
AKAtthasak Kiang-Ia
Atthasak Kiang-Ia
PTPairash Thajchayapong
Pairash Thajchayapong
In comparison to conventional medical computed tomography (CT), cone-beam CT (CBCT) has become widely used in dental and maxillofacial applications due to its accurate 3D information, high resolution, minimal radiation dose, and affordable machine cost. In this study, we investigated the image quality and radiation doses of dental CBCT and X-ray machines developed in Thailand. Our in-house reconstruction algorithm including artifact reduction was based on GPU calculations of filtered backprojection and was significantly faster than a CPU-based algorithm. The image quality aspects for CBCT were evaluated in terms of high contrast resolution, gray value uniformity, noise, and geometric accuracy, while image quality assessment for 2D images included high contrast resolution, low contrast levels, and distortion rate. Radiation doses were measured and calculated for the dose-area product (DAP). The technical image quality and radiation dose assessment was compared with those of other commercial extraoral imaging machines. The findings demonstrate that, when compared to other units, the proposed 2D and 3D extraoral imaging systems yielded comparable technical image quality and radiation doses. Based on these results, the Thai-made 2D and 3D extraoral imaging machines appear suitable for further clinical evaluation.

30 May 2018
Verified
Book Chapter
Closed access
PDF file
STSaowapak S. Thongvigitmanee
Saowapak S. Thongvigitmanee
WNWalita Narkbuakaew
Walita Narkbuakaew
SASorapong Aootaphao
Sorapong Aootaphao
CTChalinee Thanasupsombat
Chalinee Thanasupsombat
KWKongyot Wangkaoom
Kongyot Wangkaoom
PTPairash Thajchayapong
Pairash Thajchayapong