Atthasak Kiang-Ia

Atthasak Kiang-Ia

Auto-generated profile, based on publicly available information

Atthasak Kiang-Ia

Medical Imaging System Research Team, Assistive Technology and Medical Devices Research Group, National Electronics and Computer Technology Center, Klong Luang, Pathum Thani, Thailand

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in BioMed Research International
Verified
Journal Article
Open access
PDF file
UTUdomchai Techavipoo
Udomchai Techavipoo
NSNattawut Sinsuebphon
Nattawut Sinsuebphon
SPSakunrat Prompalit
Sakunrat Prompalit
STSaowapak Thongvigitmanee
Saowapak Thongvigitmanee
WNWalita Narkbuakaew
Walita Narkbuakaew
UCUtairat Chaumrattanakul
Utairat Chaumrattanakul
Background. The National Science and Technology Development Agency (NSTDA) in Thailand researched and prototyped digital radiography systems under the brand name BodiiRay aiming for sustainable development and affordability of medical imaging technology. The image restoration and enhancement were implemented for the systems. Purpose. The image quality of the systems was evaluated using images from phantoms and from healthy volunteers. Methods. The survey phantom images from BodiiRay and other two commercial systems using the exposure settings for the chest, the abdomen, and the extremity were evaluated by three experience observers in terms of the high‐contrast image resolution, the low‐contrast image detectability, and the grayscale differentiation. The volunteer images of the chests, the abdomens, and the extremities from BodiiRay were evaluated by three specialized radiologists based on visual grading on 5‐point scaled questionnaires for the anatomy visibility, the image quality satisfaction, and the diagnosis confidence in using the images. Results. BodiiRay phantom results were similar to those from the commercial systems. The overall performance averaged across the exposure settings showed that BodiiRay was slightly better than Fujifilm FDR Go in the low‐contrast detectability (p = 0.033) and in the grayscale differentiation (p = 0.004). It was also slightly better than Siemens YSIO Max in the high‐contrast resolution (p = 0.018). The images of chest, pelvis, and hand phantoms illustrated comparable visual quality. For volunteer images, the percentage of the images scored ≥4 ranged from 61% to 99%, 23% to 92%, and 96% to 99% for the chest, abdomen, and extremity images, respectively. The average score ranged from 3.63 to 4.46, 3.18 to 4.21, and 4.41 to 4.51 for the chest, abdomen, and extremity images, respectively. Conclusion. The phantom image results showed the comparability of these systems. The clinical evaluation showed BodiiRay images provided sufficient image qualities for digital radiography of these body parts.

10 April 2026 in Journal of X-Ray Science and Technology
Verified
Journal Article
Closed access
STSaowapak S Thongvigitmanee
Saowapak S Thongvigitmanee
KKKittipong Kasantikul
Kittipong Kasantikul
CTChalinee Thanasupsombat
Chalinee Thanasupsombat
WNWalita Narkbuakaew
Walita Narkbuakaew
AKAtthasak Kiang-Ia
Atthasak Kiang-Ia
PTPairash Thajchayapong
Pairash Thajchayapong
In comparison to conventional medical computed tomography (CT), cone-beam CT (CBCT) has become widely used in dental and maxillofacial applications due to its accurate 3D information, high resolution, minimal radiation dose, and affordable machine cost. In this study, we investigated the image quality and radiation doses of dental CBCT and X-ray machines developed in Thailand. Our in-house reconstruction algorithm including artifact reduction was based on GPU calculations of filtered backprojection and was significantly faster than a CPU-based algorithm. The image quality aspects for CBCT were evaluated in terms of high contrast resolution, gray value uniformity, noise, and geometric accuracy, while image quality assessment for 2D images included high contrast resolution, low contrast levels, and distortion rate. Radiation doses were measured and calculated for the dose-area product (DAP). The technical image quality and radiation dose assessment was compared with those of other commercial extraoral imaging machines. The findings demonstrate that, when compared to other units, the proposed 2D and 3D extraoral imaging systems yielded comparable technical image quality and radiation doses. Based on these results, the Thai-made 2D and 3D extraoral imaging machines appear suitable for further clinical evaluation.