Johannes Hensler

Johannes Hensler

Auto-generated profile, based on publicly available information

Johannes Hensler

Department of Radiology and Neuroradiology, University Hospital Schleswig-Holstein, Arnold-Heller-Str. 3, 24105 Kiel, Germany

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2022 in Interventional Neuroradiology
Verified
Journal Article
Closed access
PDF file
FWFritz Wodarg
Fritz Wodarg
YOYigit Oezpeynirci
Yigit Oezpeynirci
JHJohannes Hensler
Johannes Hensler
OJOlav Jansen
Olav Jansen
TLThomas Liebig
Thomas Liebig
Purpose: Wide-necked bifurcation aneurysms, partially thrombosed, and recurrences of large and giant aneurysms are challenging to treat. We report our preliminary experience with a Contour-assisted coiling technique and discuss the periprocedural safety, feasibility, and effectiveness of the approach. Methods: We retrospectively reviewed consecutive patients who received endovascular treatment for intracranial aneurysms with an intra-aneurysmal flow disruptor (Contour) at two neurovascular centres between October 2018 and December 2020 and identified patients treated with a combination of Contour and platinum coils. Clinical and procedural data were recorded. Results: For this analysis, 8 patients (5 female) aged 60.1 ± 9.2 years on average were identified. Three of 8 aneurysms were associated with previous acute subarachnoid hemorrhage (SAH). The mean average dome height was 12.8 ± 7.6 mm, mean maximum dome width 10.3 ± 5.4 mm, and neck width 5.5 ± 2.5 mm. The mean dome-to-neck ratio was 1.9 ± 1.0. Immediate complete occlusion of the aneurysm was seen in 5 of 8 cases. In one SAH patient, a parent vessel was temporarily occluded but could be reopened rapidly. One device detached prematurely without any sequelae. No other procedural adverse events were recorded. Conclusion: From this initial experience, Contour with adjunctive coiling is a safe and technically feasible method for endovascular treatment of large, wide-necked, partially thrombosed, recurrent, or ruptured bifurcation aneurysms. Further studies with larger numbers of patients and longer follow-up are needed to confirm our results.

15 July 2019 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
JPJohannes Pfaff
Johannes Pfaff
CMChristoph Maurer
Christoph Maurer
EBErasmia Broussalis
Erasmia Broussalis
HJHendrik Janssen
Hendrik Janssen
RBRaphael Blanc
Raphael Blanc
MMMarkus A. Möhlenbruch
Markus A. Möhlenbruch
Purpose: To evaluate the occurrence and risk factors of acute in-stent thrombosis or stent occlusion in patients with tandem occlusions receiving intracranial mechanical thrombectomy and emergent extracranial internal carotid artery stenting with a dual layer carotid stent.Methods: Multicenter retrospective data collection and analysis of stroke databases of seven comprehensive stroke centers from three European countries.Results: Overall, 160 patients (mean (SD) age 66 (12) years; 104 men (65%); median (IQR) baseline NIHSS 14 (9–18); IV lysis, n=97 (60.6%)) were treated for a cervical carotid artery occlusion or stenosis using a CASPER stent (MicroVention), and received mechanical thrombectomy for an intracranial occlusion between April 2014 and November 2018. During the procedure or within 72 hours, formation of thrombus and complete occlusion of the CASPER stent was observed in 33/160 (20.8%) and in 12/160 patients (7.5%), respectively. In 25/33 (75.8%) and in 9/12 patients (75%), respectively, this occurred during the procedure. No statistically significant difference was observed between patients with and without thrombus formation with regard to pre-existing long term medication with anticoagulants or intraprocedural administration of heparin, acetylsalicylic acid (ASA), or heparin and ASA. Favorable early neurological outcome was similar in patients with (n=15; 45.5%) and without (n=63; 49.6%) thrombus formation at the CASPER stent.Conclusion: Acute thrombosis or occlusion of CASPER stents in thrombectomy patients receiving emergent extracranial internal carotid artery stenting for tandem occlusions were observed more often during the procedure than within 72 hours of follow-up, were less frequent then previously reported, and showed no impact on early neurological outcome.

11 August 2016 in Neuroradiology
Verified
Journal Article
Closed access
PDF file
JHJohannes Hensler
Johannes Hensler
UJUlf Jensen-Kondering
Ulf Jensen-Kondering
SUStephan Ulmer
Stephan Ulmer
OJOlav Jansen
Olav Jansen

12 May 2021 in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Verified
Journal Article
Closed access
PDF file
JJJulia Juhász
Julia Juhász
JHJohannes Hensler
Johannes Hensler
OJOlav Jansen
Olav Jansen
Background Pseudotumor cerebri, also known as idiopathic intracranial hypertension, is a disorder of increased intracranial pressure of unknown etiology. Main symptom is headache which has a characteristic similar to other headache diseases, therefore the idiopathic intracranial hypertension often remains undetected. The incidence is 1/100 000 with the number of unreported cases being much higher. This article highlights the essential role of MRI in the differential diagnosis. Methods A literature search was carried out on idiopathic intracranial hypertension and Pseudotumor cerebri in English and German. Original and Review articles as well as case reports were taken into account. Since the main focus of the article is MRI diagnostics, some images were selected to illustrate the characteristic MRI morphological features. Results and Conclusion The diagnosis of idiopathic intracranial hypertension is based on an exclusion procedure. Most common syndromes are headache, transient visual obscurations, pulsatile tinnitus and nausea. In the presence of an underlying cause for the increased intracranial pressure one speaks of a secondary intracranial hypertension. The diagnostics include a detailed medical history, neurological and ophthalmic examination, lumbar puncture, and neuroradiological imaging procedures. MRI, in particular, has become increasingly important in recent years, since signs for changes in cerebrospinal fluid pressure are now detectable and well-defined. The therapeutic approaches are symptom-oriented and aim to lower the pressure. With a precise diagnosis and timely start of therapy, idiopathic intracranial hypertension has a good prognosis, especially with regard to the preservation of eyesight. Key Points: Citation Format

19 November 2020 in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Verified
Journal Article
Closed access
PDF file
JMJawid Madjidyar
Jawid Madjidyar
LNLars Nekarda
Lars Nekarda
NLNaomi Larsen
Naomi Larsen
FWFritz Wodarg
Fritz Wodarg
JHJohannes Hensler
Johannes Hensler
OJOlav Jansen
Olav Jansen
A direct aspiration first pass technique (ADAPT) is an effective thrombectomy option in patients with acute ischemic stroke. Balloon guide catheters (BGC) seem to improve the efficacy of stent retrievers and ADAPT. The last generation 6F aspiration catheters require 9F BGCs, which are rigid devices that are challenging to position in a tortuous anatomy. In this experimental study the efficacy of 6F ADAPT alone and 5F ADAPT combined with 8F BGC was evaluated.Either a fibrin rich (white) clot or an RBC rich (red) clot was placed in the M1 segment of a transparent silicon phantom. Physiological hemodynamic conditions were maintained. The clots were retrieved by 6F aspiration catheter via 8F long sheath or 5F aspiration catheter via a flexible 8F BGC. Thrombectomy was performed under direct visual control. The primary endpoints were the number of passes and the number of distal emboli.Ten experiments were made with each clot model and thrombectomy technique (n = 40). Full recanalization could be achieved in every experiment. First pass mTICI 3 could be achieved by 6F ADAPT in 80 % of red clots and 90 % of white clots. Distal emboli were caused in 10 % and 20 %, respectively. When using 5F ADAPT combined with BGC, a first pass mTICI 3 rate of 90 % in red clots and 100 % in white clots could be achieved. A 10 % rate of distal emboli occurred in both groups. In almost all experiments (both techniques), the thrombi clogged the aspiration catheter. No statistically significant differences could be found between the techniques and clot models.6F ADAPT without BGC was as effective as 5F ADAPT combined with a flexible 8F BGC, with both techniques showing high first-pass recanalization rates and low distal emboli rates. Especially in the case of a tortuous anatomy, these setups should be considered as alternatives to a rigid 9F BGC. The thrombus compositions seemed to be irrelevant in this setting.

2 September 2024 in Interventional Neuroradiology
Verified
Journal Article
Closed access
JMJawid Madjidyar
Jawid Madjidyar
MPMariya Pravdivtseva
Mariya Pravdivtseva
JHJohannes Hensler
Johannes Hensler
OJOlav Jansen
Olav Jansen
NLNaomi Larsen
Naomi Larsen
FWFritz Wodarg
Fritz Wodarg
Purpose: The contour neurovascular system (CNS) is an intrasaccular flow-disrupting device designed for the treatment of intracranial wide-necked bifurcation aneurysms. Metal artifacts limit magnetic resonance imaging (MRI) accessibility after implantation. The purpose of this in vitro study was to evaluate non-invasive imaging alternatives to digital subtraction angiography (DSA). Material and methods: Three aneurysms of patients originally treated with CNS were three-dimensional (3D)-printed (one at the basilar tip and two at the middle cerebral artery bifurcation). CNS devices were implanted under fluoroscopic control into the 3D models. Post-implantation two-dimensional-DSA, flat panel computed tomography angiography (CTA), MRI, and spectral CTA were performed. Results: Time of flight angiography and T1 weighted sequences showed large susceptibility artifacts at the detachment zone of the devices. A thin-sliced T2 weighted sequence in cross-sectional orientation to the aneurysm allowed visualization of the aneurysm dome, but the aneurysm neck and parent vessel could not be assessed. Focused spectral CTA, especially a 40 keV reconstruction with a metal artifact reduction algorithm (orthopedic metal artifact reduction (OMAR)), showed only minor artifacts at the detachment zone. This approach achieved a very similar result to DSA and flat panel computed tomography, enabling the assessment of the device structure, aneurysm perfusion, and parent vessel perfusion. Discussion and conclusion: For non-invasive follow-up of CNS, focused 40 keV CTA with OMAR seems to be a valuable option. MRI can be valuable for larger aneurysms to assess the aneurysm dome, but was not suitable for evaluating the parent vessels and aneurysm neck after CNS implantation in this study.