Fritz Wodarg

Fritz Wodarg

Auto-generated profile, based on publicly available information

Fritz Wodarg

Department of Radiology and Neuroradiology, Universitatsklinikum Schleswig-Holstein Campus Kiel, Kiel, Germany

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2020 in Neuroradiology
Verified
Journal Article
Open access
PDF file
NLNaomi Larsen
Naomi Larsen
CFCharlotte Flueh
Charlotte Flueh
SSSylvia Saalfeld
Sylvia Saalfeld
SVSamuel Voß
Samuel Voß
GHGeorg Hille
Georg Hille
PBPhilipp Berg
Philipp Berg
Purpose: Circumferential enhancement on MR vessel wall imaging has been proposed as a biomarker of a higher risk of rupture in intracranial aneurysms. Focal enhancement is frequently encountered in unruptured aneurysms, but its implication for risk stratification and patient management remains unclear. This study investigates the association of focal wall enhancement with hemodynamic and morphological risk factors and histologic markers of wall inflammation and degeneration. Methods: Patients with an unruptured middle cerebral artery aneurysm who underwent 3D rotational angiography and 3T MR vessel wall imaging showing focal wall enhancement were included. Hemodynamic parameters were calculated based on flow simulations and compared between enhanced regions and the entire aneurysm surface. Morphological parameters were semiautomatically extracted and quantitatively associated with wall enhancement. Histological analysis included detection of vasa vasorum, CD34, and myeloperoxidase staining in a subset of patients. Results: Twenty-two aneurysms were analyzed. Enhanced regions were significantly associated with lower AWSS, lower maxOSI, and increased LSA. In multivariate analysis, higher ellipticity index was an independent predictor of wall enhancement. Histologic signs of inflammation and degeneration and higher PHASES score were significantly associated with focal enhancement. Conclusion: Focal wall enhancement is colocalized with hemodynamic factors that have been related to a higher rupture risk. It is correlated with morphological factors linked to rupture risk, higher PHASES score, and histologic markers of wall destabilization. The results support the hypothesis that focal enhancement could serve as a surrogate marker for aneurysm instability.

19 April 2018 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
PDF file
FWFritz Wodarg
Fritz Wodarg
ETElisabeth L Turner
Elisabeth L Turner
JDJoanna Dobson
Joanna Dobson
PRPeter A Ringleb
Peter A Ringleb
WMWillem P Mali
Willem P Mali
LBLeo H Bonati
Leo H Bonati
Background and purpose Carotid artery stenting is an alternative to endarterectomy for the treatment of symptomatic carotid stenosis but was associated with a higher risk of procedural stroke or death in randomized controlled trials (RCTs). Technical aspects of treatment may partly explain these results. The purpose of this analysis was to investigate the influence of technical aspects such as stent design or the use of protection devices, as well as clinical variables, on procedural risk. Methods We pooled data of 1557 individual patients receiving stent treatment in three large RCTs comparing stenting versus endarterectomy for symptomatic carotid stenosis. The primary outcome event was any procedural stroke or death occurring within 30 days after stenting. Results Procedural stroke or death occurred significantly more often with the use of open-cell stents (61/595 patients, 10.3%) than with closed-cell stents (58/962 patients, 6.0%; RR 1.76; 95% CI 1.23 to 2.52; P=0.002). Procedural stroke or death occurred in 76/950 patients (8.0%) treated with protection devices (predominantly distal filters) and in 43/607 (7.1%) treated without protection devices (RR 1.10; 95% CI 0.71 to 1.70; P=0.67). Clinical variables predicting the primary outcome event were age, severity of the qualifying event, history of prior stroke, and level of disability at baseline. The effect of stent design remained similar after adjustment for these variables. Conclusions In symptomatic carotid stenosis, the use of stents with a closed-cell design is independently associated with a lower risk of procedural stroke or death compared with open-cell stents. Filter-type protection devices do not appear to reduce procedural risk.

3 September 2020 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Open access
PDF file
AFAndreas Maximilian Frölich
Andreas Maximilian Frölich
WKWarren Kim
Warren Kim
KSKnut Stribrny
Knut Stribrny
OJOlav Jansen
Olav Jansen
MMMarkus Möhlenbruch
Markus Möhlenbruch
JEJoey English
Joey English
Background In large vessel occlusionstroke, navigation of aspiration catheters (AC) can be impeded by vessel tortuosity and the ophthalmic artery origin. A novel tapered delivery catheter was designed to facilitate delivery without disturbing the embolus. We assessed AC deliverability in vitro and validated the observations in a first-in-human experience. Methods In a vascular model with three challenging craniocervical scenarios, two commercial AC were advanced from the carotid to the middle cerebral artery by four neurointerventionalists. Catheter deliverability with standard microwire and microcatheter (MC) combinations and the Tenzing 7 (T7) Delivery Catheter (Route 92 Medical, San Mateo, CA) were compared. Operators rated aspects of catheter deliverability on a 5-point scale. Results were compared with device delivery patterns at a neurovascular center before and after clinical introduction of T7. Results In vitro, success rate and speed were higher with T7 (96%; mean 30±10 s) than with MC (65%; 72±47 s, p<0.001 each), with fewer interactions with the occlusion site (T7: 54% vs MC: 77%, p=0.004). T7 received superior ratings regarding carotid artery deflection (T7: 2, IQR1-3 vs MC: 3, IQR2-3, p<0.001), guide catheter pushback (T7: 2, IQR1-3 vs MC: 3, IQR3-3, p<0.001) and ophthalmic artery passage (T7: 1.5, IQR1-2 vs MC: 4, IQR3-5, p<0.001). Before introduction of T7 at a single center, delivery of AC to a large vessel occlusion without crossing was achieved in 15/123 cases (12%). With T7, this rate was 28/31 patients (90.3%). Conclusion Compared with microcatheter and microwire combinations, T7 improves aspiration catheter delivery in vitro, minimizing the need to cross the occlusion. Initial clinical experience appears to validate the model’s observations.

1 November 2023 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Open access
PDF file
LSLaurent Spelle
Laurent Spelle
VCVincent Costalat
Vincent Costalat
JCJildaz Caroff
Jildaz Caroff
FWFritz Wodarg
Fritz Wodarg
Sebastian FischerSebastian Fischer
Sebastian Fischer
CCChristophe Cognard
Christophe Cognard
Background Intrasaccular flow disruption is an endovascular approach for the treatment of wide-neck aneurysms and, more specifically, wide-neck bifurcation aneurysms, which are challenging to treat with previously developed technologies. The Woven EndoBridge (WEB) device has demonstrated its efficacy and safety, for both unruptured and ruptured aneurysms. Methods The CLEVER study was an observational, multicenter, prospective study conducted in 17 European investigational sites using the WEB 17 device, for the treatment of ruptured and unruptured aneurysms. The study objective was to provide safety and efficacy data on the WEB 17 device in the treatment of wide-neck bifurcation aneurysms. Imaging results were assessed independently by a Corelab and adverse events adjudicated by a Clinical Event Adjudicator. This analysis reports procedural results and safety at 30 days and 12 months. Results A total of 163 patients (mean age 58.1 years; 68.1% women) with 103 unruptured aneurysms and 60 ruptured aneurysms were enrolled. Most aneurysms were located on the anterior communicating artery (ACom) (37.4%) or the middle cerebral artery (MCA) bifurcation (30.1%). Aneurysm widths ranged from 2.0–9.2 mm, and the mean sac width was 5.0 mm. The WEB procedure was successfully completed in 163 patients (100%). At the 12-month follow-up, major stroke events occurred in 3 of 163 patients (1.8%), and no device-related mortality was observed. Conclusion Endovascular treatment of ruptured and unruptured wide-neck bifurcation aneurysms using WEB 17 is safe, with a low complication rate and no device-related mortality. In particular, none of the ruptured aneurysms bled again up to 1 year of follow-up. Trial registration number NCT03844334.

11 January 2022 in Interventional Neuroradiology
Verified
Journal Article
Closed access
PDF file
FWFritz Wodarg
Fritz Wodarg
YOYigit Oezpeynirci
Yigit Oezpeynirci
JHJohannes Hensler
Johannes Hensler
OJOlav Jansen
Olav Jansen
TLThomas Liebig
Thomas Liebig
Purpose: Wide-necked bifurcation aneurysms, partially thrombosed, and recurrences of large and giant aneurysms are challenging to treat. We report our preliminary experience with a Contour-assisted coiling technique and discuss the periprocedural safety, feasibility, and effectiveness of the approach. Methods: We retrospectively reviewed consecutive patients who received endovascular treatment for intracranial aneurysms with an intra-aneurysmal flow disruptor (Contour) at two neurovascular centres between October 2018 and December 2020 and identified patients treated with a combination of Contour and platinum coils. Clinical and procedural data were recorded. Results: For this analysis, 8 patients (5 female) aged 60.1 ± 9.2 years on average were identified. Three of 8 aneurysms were associated with previous acute subarachnoid hemorrhage (SAH). The mean average dome height was 12.8 ± 7.6 mm, mean maximum dome width 10.3 ± 5.4 mm, and neck width 5.5 ± 2.5 mm. The mean dome-to-neck ratio was 1.9 ± 1.0. Immediate complete occlusion of the aneurysm was seen in 5 of 8 cases. In one SAH patient, a parent vessel was temporarily occluded but could be reopened rapidly. One device detached prematurely without any sequelae. No other procedural adverse events were recorded. Conclusion: From this initial experience, Contour with adjunctive coiling is a safe and technically feasible method for endovascular treatment of large, wide-necked, partially thrombosed, recurrent, or ruptured bifurcation aneurysms. Further studies with larger numbers of patients and longer follow-up are needed to confirm our results.

10 December 2020 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
DVDominik F. Vollherbst
Dominik F. Vollherbst
ABA. Berlis
A. Berlis
CMC. Maurer
C. Maurer
LBL. Behrens
L. Behrens
SSStanimir Stefanov Sirakov
Stanimir Stefanov Sirakov
MMMarkus A. Möhlenbruch
Markus A. Möhlenbruch
BACKGROUND AND PURPOSE: Stent-assisted treatment techniques can be an effective treatment option for intracranial aneurysms. The aim of this study was to evaluate the periprocedural feasibility and safety of the new LVIS EVO stent for the treatment of intracranial aneurysms. MATERIALS AND METHODS: Patients with intracranial aneurysms treated with the LVIS EVO in 11 European neurovascular centers were retrospectively reviewed. Patient and aneurysm characteristics, procedural parameters, immediate grade of occlusion, and technical and clinical complications were assessed. RESULTS: Fifty-seven patients with 59 aneurysms were treated with the LVIS EVO device; 57.6% of the aneurysms were incidental; 15.3% were acutely ruptured; 15.3% were recanalized or residual aneurysms; and 11.9% were treated for symptoms other than acute hemorrhage. The most frequent aneurysm locations were the middle cerebral artery (25.4%) and the anterior communicating artery (22.0%). The rate of immediate successful deployment was 93.2%. In 6.8% (n = 4) of cases, additional in-stent angioplasty was needed. The immediate complete occlusion rate was 54.2%, while there was a residual aneurysm in 35.6% and a residual neck in 10.2%. Periprocedural technical complications occurred in 7/59 treatments (11.9%; the most frequent technical complication [n = 3] was thrombus formation), which all resolved completely without clinical sequelae. Postprocedural neurologic complications occurred after 4/59 treatments (6.8%; 2 transient ischemic attacks, 1 minor stroke, 1 major stroke), of which only 1 persistent complication was directly related to the procedure (minor stroke in the vascular territory distal to the stent). CONCLUSIONS: The LVIS EVO stent is a safe, feasible device for the treatment of intracranial aneurysms.