Thi Anh Tuyet Ngo

Thi Anh Tuyet Ngo

Auto-generated profile, based on publicly available information

Thi Anh Tuyet Ngo

Institute of Material Science of Vietnam Academy of Science and Technology

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Surface and Coatings Technology
Verified
Journal Article
Closed access
TNTuyet T.A. Ngo
Tuyet T.A. Ngo
SHSachiko Hiromoto
Sachiko Hiromoto
SPSan T. Pham
San T. Pham
NQNguyen Cao Quang
Nguyen Cao Quang

23 May 2021 in Journal of Biomaterials Applications
Verified
Journal Article
Closed access
PDF file
TNTuyet Thi Anh Ngo
Tuyet Thi Anh Ngo
SHSachiko Hiromoto
Sachiko Hiromoto
LDLinh Chi Do
Linh Chi Do
HPHanh Hong Pham
Hanh Hong Pham
LHLe Hanh
Le Hanh
Hydroxyapatite (HAp) and octacalcium phosphate (OCP) layers were formed on Mg- 4mass% Y- 3mass% rare earth (WE43) alloy by a chemical solution deposition method at various pH values of pH 5.5, 6.2, 7.5, and 8.6. Adhesion strength of HAp and OCP layers was evaluated before and after immersing in a medium for 14 days by a pull-off test. The corrosion resistance of these coatings was measured by polarization tests performed in a simulated body fluid (SBF). XRD analysis demonstrated that HAp coating layers were formed at pH 7.5 and 8.6, while OCP coating layers were formed at pH 5.5 and 6.2. Adhesion test results showed that the as-coated pH7.5-HAp layer had the highest adhesion strength of 8.6 MPa, which was attributed to the very dense structure of the coating layer. The as-coated pH8.6-HAp layer showed the adhesion strength of 6.5 MPa. The adhesion strength of the as-coated pH5.5- and pH6.2-OCP layers was 3.9 and 7.1 MPa, respectively, that was governed by the thick and fragile property of the layers. After immersing in the medium for 14 days, the adhesion strength of pH7.5- and pH8.6-specimens decreased to 5.8 and 5.6 MPa, respectively. The pitting corrosion and formation of Mg(OH)2 under the HAp layers were responsible for the decrease of adhesion strength. The polarization tests in SBF at 37 °C showed that the corrosion current density decreased with the HAp and OCP coatings, indicating the improvement of the corrosion resistance of WE43 alloy. The HAp coatings improved the corrosion resistance more efficiently than the OCP coatings.

1 January 2024 in Journal of Applied Biomaterials & Functional Materials
Verified
Journal Article
Open access
ANAnh Tuyet Thi Ngo
Anh Tuyet Thi Ngo
LCLinh Do Chi
Linh Do Chi
HPHanh Hong Pham
Hanh Hong Pham
SPSan Thy Pham
San Thy Pham
DLDuong Van Luong
Duong Van Luong
Objectives: The primary objective of this study is using an anodizing intermediate layer to improve corrosion resistance and adhesion of hydroxyapatite coated AZ31 alloy for applications in biodegradable implants. Methods: An anodizing intermediate layer was formed on the surface of AZ31 substrate at various anodizing voltage of 10, 20, 30, and 40 V respectively by anodizing process. HAp was grow on the surface of AZ31 substrate at 90°C and pH solution of 7.5 by chemical solution treatment method for 2 h. The coated samples were evaluated their corrosion behavior by Electrochemical measurements and biodegradation behavior by immersion test in Hank’s balanced salts solution (HBSS) for 28 days via amount of Mg2+ ion released. While, their adhesion strength were evaluated by pull-off method. The amount of Mg2+ ions released of the samples was quantified by the Inductively coupled plasma mass spectrometry. Results: An anodizing intermediate layer was successfully synthesized at various voltages by anodizing process and HAp coatings were prepared by chemical solution treatment method. The corrosion rate of hydroxyapatite coated AZ31 alloy with an anodizing intermediate layer decreased 4.4 times, while adhesion strength increased about two times compared to the HAp coated AZ31 specimen without an anodizing layer and achieved ~14.70, ~6.92 MPa, respectively. After immersion test in HBSS, the adhesion strength of HAp/AZ31-HBSS-specimen decrease to 45% because of large corroded areas with depth holes of hundreds of micrometers. The slighter decrease in adhesion strength of HAp/30V/AZ31-HBSS-specimen to 22% is due to the contribution of the anodizing intermediate layer. Conclusion: HAp coated AZ31 alloy specimen with the existence of a porous structure with an elliptical shape, uniform and high density of MgO on the surface at anodizing voltage of 30 V resulted in a significant increase in corrosion resistance and the adhesion strength of HAp coatings.

5 February 2024 in Communications in Physics
Verified
Journal Article
Open access
PDF file
BHBui Thi Hoa
Bui Thi Hoa
GTGiang Nguyen Thi
Giang Nguyen Thi
HPHong Hanh Pham
Hong Hanh Pham
TATuyet Ngo Thi Anh
Tuyet Ngo Thi Anh
LDLinh Do
Linh Do
OVOanh Vu
Oanh Vu
This research investigates the effect of cobalt precursor and calcination time on the morphology and catalytic activity of Co3O4 films in the oxygen evolution reaction (OER). Co3O4 films with porous flower-like nanostructures were obtained using cobalt nitrate as a cobalt precursor, while cobalt chlorides were used to produce porous nanoneedle structures Co3O4 film. Extended annealing time at temperatures 350°C caused structural fractures in the films. Among the samples, the synthesized Co3O4 films were then evaluated as catalyst materials for the OER in alkaline 1M KOH electrolyte. Among synthesized films, the Co3O4-2-1h, synthesized using the cobalt chlorides as Co precursor and annealed at 350°C for 1 hour, exhibited better OER catalytic activity. With its porous nanoneedle structure, the Co3O4-2-1h demonstrated superior performance comparable to the state-of-the-art 20% Ir/C catalyst. Moreover, the Co3O4-2-1h film demonstrates remarkable stability for the OER in a 1M KOH alkaline electrolyte.

30 September 2026 in Frontier materials & technologies
Verified
Journal Article
Open access
PDF file
VRVasili Rubanik
Vasili Rubanik
DBDzmitry Bahrets
Dzmitry Bahrets
SMSergey Mozzharov
Sergey Mozzharov
NTNgo Tuyet
Ngo Tuyet
Problem. Hydroxyapatite (HA, chemical formula Ca10(PO4)6(OH)2) is widely used as a biocompatible and bioactive ceramic due to its structural and chemical similarity to the main mineral component of human hard tissues. A disadvantage of hydroxyapatite is its low mechanical properties (strength, crack resistance, and impact resistance), which undoubtedly limits its use as a structural material but not as a bioactive coating on metal implant surfaces. Electrodeposition is one of the most promising methods for forming bioactive calcium-phosphate coatings on metal implants due to the ability to control the composition, structure, and thickness of the coating at low process temperatures. Aim. The aim of this work is to identify patterns in the formation of the composition and structure of hydroxyapatite coatings produced by electrodeposition on 12X18H10T stainless steel and titanium nickelide substrates, and to optimize the deposition modes. Methods. The influence of electrolyte parameters (Ca2+ and PO4 3 ion concentration, pH, H2O2 and NaOH additives), temperature (23–85 °C), potential and deposition time on the stoichiometry, crystallinity, texture and crystallite size of HA coatings was studied using X-ray fluorescence (XRF), X-ray diffraction (XRD), and IR-spectroscopy. Results. It was shown that the brushite phase (CaHPO4·2H2O) is formed at room temperature regardless of the electrolyte composition. Increasing the temperature to 65 °C or higher, when combined with optimization of pH (4.1–6.0) and potential (−1.7…−3.4 V), allows the synthesis of coatings with a composition close to stoichiometric hydroxyapatite. The regimes ensuring the production of single-phase, highly-crystalline HA coatings with a texture coefficient of up to 2.6, which corresponds to the structure most conducive to osseointegration, were experimentally determined. Conclusions. The best coating characteristics (high crystallinity CI=9.1, crystallite size along the c-axis ~70 nm, c/a ratio=0.730) were achieved for the sample synthesized at T=75 °C, pH=5.0, and U=−1.7 V

26 February 2026 in Vietnam Journal of Science and Technology
Verified
Journal Article
Open access
PDF file
TNThi Anh Tuyet Ngo
Thi Anh Tuyet Ngo
SHSachiko Hiromoto
Sachiko Hiromoto
LCLinh Do Chi
Linh Do Chi
HPHanh Hong Pham
Hanh Hong Pham
SPSan Thy Pham
San Thy Pham
TGThai Hong Giang
Thai Hong Giang
In recent years, biodegradable implants have emerged as an alternative material to avoid long-term complications caused by permanent implants in applications that require a device with a temporary short function, such as endovascular stents and bone repair implants. Mg and some of its alloys are biocompatible materials and have good mechanical properties, which make them become suitable candidates for biodegradable applications. Hydroxyapatite (HAp) has been demonstrated to be an effective coating material to improve corrosion resistance and biocompatibility of the implant materials. In addition, HAp is able to promote bone formation during implantation. In this study, the hydroxyapatite layer (HAp) was formed on the Mg- 4% Y- 3% rare earth alloy (WE43) by a chemical solution deposition method at various coating times from 0,5 hours to 4 hours. The adhesion of HAp layers was evaluated by the pull-off test method. The corrosion resistance of these coatings was measured by polarization tests and Nyquist impedance spectrum performed in a simulated body fluid (SBF) at 37±1oC. XRD analysis demonstrated that HAp coating layers were formed in whole specimens, while the highest intensity of HAp peak was formed at specimens with coating times of 2 and 4 hours. Adhesion test results showed that the coating time of 2 hours-HAp layer had the highest adhesion strength of 6.46 MPa, attributed to the very dense structure and the rod-liked HAp crystal of the outer-coating layer. The corrosion and formation of Mg(OH)2 under the HAp layers were responsible for the decrease in adhesion strength. The polarization tests in SBF at 37±1 oC showed that the corrosion current density decreased with the coating times from 0.5 to 2 hours, and the HAp layer on WE43 was formed on the coating time of 2 hours -specimen improved the corrosion resistance more efficiently than that on other coating times.