Smartphone microscopes can be useful tools for a broad range of imaging applications. This manuscript demonstrates the first practical implementation of Microscopy with Ultraviolet Surface Excitation (MUSE) in a compact smartphone microscope called Pocket MUSE, resulting in a remarkably effective design. Fabricated with parts from consumer electronics that are readily available at low cost, the small optical module attaches directly over the rear lens in a smartphone. It enables high-quality multichannel fluorescence microscopy with submicron resolution over a 10× equivalent field of view. In addition to the novel optical configuration, Pocket MUSE is compatible with a series of simple, portable, and user-friendly sample preparation strategies that can be directly implemented for various microscopy applications for point-of-care diagnostics, at-home health monitoring, plant biology, STEM education, environmental studies, etc.
In the clinical practice of pathology, trichrome stains are commonly used to highlight collagen and to help evaluate fibrosis. Such stains do delineate collagen deposits but are not molecularly specific and can suffer from staining inconsistencies. Moreover, performing histochemical stain evaluation requires the preparation of additional sections beyond the original hematoxylin- and eosin-stained slides, as well as additional staining steps, which together add cost, time, and workflow complications. We have developed a new microscopy approach, termed DUET (DUal-mode Emission and Transmission) that can be used to extract signals that would typically require special stains or advanced optical methods. Our preliminary analysis demonstrates the potential of using the resulting signals to generate virtual histochemical images that resemble trichrome-stained slides and can support clinical evaluation. We demonstrate advantages of this approach over images acquired from conventional trichrome-stained slides and compare them with images created using second harmonic generation microscopy.
Fluorescence-guided surgery (FGS) for primary brain tumor (glioma) resection using 5-aminolevulinic acid (5-ALA) improves the extent of tumor resection in high-grade glioma patients, directly impacting patient survival. Its use is a widespread practice in Europe and is rapidly gaining popularity in the United States.1 Oral administration of 5-ALA results in selective accumulation of protoporphyrin IX (PpIX) in tumor cells.2 In glioblastoma (GBM) patients, PpIX fluorescence (emission peak at 635 nm upon 405 nm excitation3) is strong enough for visual assessment using a surgical microscope, and it enables guided tumor resection. However, for the low-cellularity infiltrating edge of high-grade gliomas and most low-grade gliomas, the PpIX fluorescence intensity decreases below the visible threshold.4 Current implementations of PpIX fluorescence visualization systems require working in a dark surgical field, hindering simultaneous tumor identification and resection. Additionally, visible PpIX fluorescence suffers from non-specific intensity variations (e.g., non-uniform illumination) that complicate the quantitative assessment of tumor with high accuracy.5 Recent studies conducted on excised brain tissue have suggested that fluorescence spectroscopy and lifetime imaging enable further quantification of PpIX fluorescence below the visible detection threshold.6,7 Time-resolved fluorescence is expected to increase the detection sensitivity of areas with weak fluorescence intensity because fluorescence lifetime is largely independent of tissue absorption and scattering properties, and unlike intensity alone, it is robust to variations in tissue-detector distance.
12 April 2023 in IEEE Transactions on Biomedical Engineering
Intraoperative identification of head and neck cancer tissue is essential to achieve complete tumor resection and mitigate tumor recurrence. Mesoscopic fluorescence lifetime imaging (FLIm) of intrinsic tissue fluorophores emission has demonstrated the potential to demarcate the extent of the tumor in patients undergoing surgical procedures of the oral cavity and the oropharynx. Here, we report FLIm-based classification methods using standard machine learning models that account for the diverse anatomical and biochemical composition across the head and neck anatomy to improve tumor region identification. Three anatomy-specific binary classification models were developed (i.e., “base of tongue,” “palatine tonsil,” and “oral tongue”). FLIm data from patients (N = 85) undergoing upper aerodigestive oncologic surgery were used to train and validate the classification models using a leave-one-patient-out cross-validation method. These models were evaluated for two classification tasks: (1) to discriminate between healthy and cancer tissue, and (2) to apply the binary classification model trained on healthy and cancer to discriminate dysplasia through transfer learning. This approach achieved superior classification performance compared to models that are anatomy-agnostic; specifically, a ROC-AUC of 0.94 was for the first task and 0.92 for the second. Furthermore, the model demonstrated detection of dysplasia, highlighting the generalization of the FLIm-based classifier. Current findings demonstrate that a classifier that accounts for tumor location can improve the ability to accurately identify surgical margins and underscore FLIm's potential as a tool for surgical guidance in head and neck cancer patients, including those subjects of robotic surgery
14 May 2014 in Methods and Applications in Fluorescence
The combined analysis of spectral and lifetime images has the potential to provide more accurate and more detailed information about Förster resonance energy transfer (FRET). We have developed a novel FRET analysis method to analyze images recorded by multispectral lifetime imaging. The new method is based on a phasor approach and facilitates the simultaneous analysis of decay kinetics of donor and acceptor molecules. The method is applicable to both molecules that exhibit a mono-exponential decay and a bi-exponential decay. As an example we show the possibility of extracting the energy transfer efficiency and the fraction of interacting molecules even in the presence of non-interacting molecules. The reliability of the method is investigated by comparing it with conventional FRET-FLIM analyses. We show that, with the same number of detected photons, the spectrally resolved phasor approach provides higher accuracy than other analysis methods; the confidence interval is improved and the FRET efficiency is closer to the real value.
Multispectral imaging (MSI) is increasingly finding application in the study and characterization of biological specimens. However, the methods typically used come with challenges on both the acquisition and the analysis front. MSI can be slow and photon-inefficient, leading to long imaging times and possible phototoxicity and photobleaching. The resulting datasets can be large and complex, prompting the development of a number of mathematical approaches for segmentation and signal unmixing. We show that under certain circumstances, just three spectral channels provided by standard color cameras, coupled with multispectral analysis tools, including a more recent spectral phasor approach, can efficiently provide useful insights. These findings are supported with a mathematical model relating spectral bandwidth and spectral channel number to achievable spectral accuracy. The utility of 3-band RGB and MSI analysis tools are demonstrated on images acquired using brightfield and fluorescence techniques, as well as a novel microscopy approach employing UV-surface excitation. Supervised linear unmixing, automated non-negative matrix factorization and phasor analysis tools all provide useful results, with phasors generating particularly helpful spectral display plots for sample exploration.