Naresh Deoli

Naresh Deoli

Auto-generated profile, based on publicly available information

Naresh Deoli

Radiological Research Accelerator Facility, Columbia University in the City of New York, 136 S. Broadway, Irvington, New York, 10533, UNITED STATES

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2018 in Life Sciences in Space Research
Verified
Journal Article
Closed access
NDNaresh T. Deoli
Naresh T. Deoli
Karl H HasensteinKarl H Hasenstein
Karl H Hasenstein

21 June 2024 in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Verified
Journal Article
Open access
HWHarry J. Whitlow
Harry J. Whitlow
AKAndrej Kuznetsov
Andrej Kuznetsov
AAAlexander Azarov
Alexander Azarov
GNGyula Nagy
Gyula Nagy
RFRobert J.W. Frost
Robert J.W. Frost
FVFrancois Villinger
Francois Villinger

11 April 2023 in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Verified
Journal Article
Open access
HWHarry J. Whitlow
Harry J. Whitlow
GNGyula Nagy
Gyula Nagy
NHNicholas Henderson
Nicholas Henderson
RGRichard Greco
Richard Greco
NDNaresh Deoli
Naresh Deoli
FVFrancois Villinger
Francois Villinger

22 February 2024 in Journal of the Energy Institute
Verified
Journal Article
Closed access
DPDevin Peck
Devin Peck
NDNaresh Deoli
Naresh Deoli
WHWilliam E. Holmes
William E. Holmes
DGDaniel Gang
Daniel Gang
MZMark Zappi
Mark Zappi
PBPrashanth Buchireddy
Prashanth Buchireddy

20 March 2022 in bioRxiv
Verified
Preprint
Open access
PDF file
SBSwathi Balaji
Swathi Balaji
WSWalker D. Short
Walker D. Short
BPBenjamin W. Padon
Benjamin W. Padon
JBJorge Alfonso Belgodere
Jorge Alfonso Belgodere
SJSarah E. Jimenez
Sarah E. Jimenez
JJJangwook P Jung
Jangwook P Jung
The application of engineered biomaterials for wound healing has been pursued since the beginning of tissue engineering. Here, we attempt to apply functionalized lignin to confer antioxidation to the extracellular microenvironments of wounds and to deliver oxygen from the dissociation of calcium peroxide for enhanced vascularization and healing responses without eliciting inflammatory responses. Elemental analysis showed 17 times higher quantity of calcium in the oxygen releasing nanoparticles. Lignin composites including the oxygen releasing nanoparticles released around 500 ppm oxygen per day at least for 7 days. By modulating the concentration of the methacrylated gelatin, we were able to maintain the injectability of lignin composite precursors and the stiffness of lignin composites suitable for wound healing after photo-crosslinking. In situ formation of lignin composites with the oxygen releasing nanoparticles enhanced the rate of tissue granulation, the formation of blood vessels and the infiltration of α-smooth muscle actin + fibroblasts into the wounds over 7 days. At 30 days after surgery, the lignin composite with oxygen generating nanoparticles remodeled the collagen architecture resembling to the reticular pattern of unwounded collagen with minimal scar formation. Thus, our study shows the potential of functionalized lignin for wound healing applications requiring balanced antioxidation and controlled release of oxygen for enhanced tissue granulation, vascularization and maturation of collagens.

6 August 2025 in Physics in Medicine & Biology
Verified
Journal Article
Open access
YTYuewen Tan
Yuewen Tan
NDNaresh T Deoli
Naresh T Deoli
AHAndrew D Harken
Andrew D Harken
DBDavid J Brenner
David J Brenner
GGGuy Garty
Guy Garty
Objective. The FLASH effect has gained significant attention in radiobiology and radiation oncology due to its potential to improve therapeutic outcomes by delivering ultra-high dose-rate (UHDR) irradiations. Understanding UHDR biological mechanisms can also contribute to the development of biodosimetry and radiological medical countermeasures. However, achieving stable and reproducible high-current UHDR electron beams has been reported to be challenging with modified clinical linear accelerator (Linac) systems, and has not been systematically studied. Approach. We investigated how key standing-wave linear accelerator parameters, including electron gun current (GUNI), pulse-forming network voltage (PFNV), and auto-frequency control (AFC), affect the stability of electron beam intensity on a modified Varian Clinac 2100C. We also developed a parameter-tuning method to adjust beam intensity and improve beam stability. Main results. This approach enabled (1) fine-tuning of dose-per-pulse without modifying the physical setup and (2) reduction of beam fluctuations, particularly during cold starts. These improvements enhanced both pulse-by-pulse stability and trial-by-trial reproducibility. The resulting stability was validated through multiple biological experiments. Significance. This work offers practical guidance for improving UHDR beam stability and reproducibility, as well as enabling intensity tuning in modified clinical linear accelerators. It can support the development of more reliable preclinical FLASH irradiators, thereby contributing to the advancement of FLASH research.