1 January 2020 in Research
Early cancer diagnosis and treatment are crucial research fields of human health. One method that has proven efficient is biomarker detection which can provide real-time and accurate biological information for early diagnosis. This review presents several biomarker sensors based on electrochemistry, surface plasmon resonance (SPR), nanowires, other nanostructures, and, most recently, metamaterials which have also shown their mechanisms and prospects in application in recent years. Compared with previous reviews, electrochemistry-based biomarker sensors have been classified into three strategies according to their optimizing methods in this review. This makes it more convenient for researchers to find a specific fabrication method to improve the performance of their sensors. Besides that, as microfabrication technologies have improved and novel materials are explored, some novel biomarker sensors—such as nanowire-based and metamaterial-based biomarker sensors—have also been investigated and summarized in this review, which can exhibit ultrahigh resolution, sensitivity, and limit of detection (LoD) in a more complex detection environment. The purpose of this review is to understand the present by reviewing the past. Researchers can break through bottlenecks of existing biomarker sensors by reviewing previous works and finally meet the various complex detection needs for the early diagnosis of human cancer.
1 January 2022 in Food Science and Technology
24 May 2021 in Diagnostic Pathology
Background: Colorectal cancer (CRC) is one of the third normal malignancy worldwide. Taurine-upregulated gene 1 (TUG1), a member of long noncoding RNAs (lncRNAs), has been reported to be involved in various cancers. However, the mechanism underlying TUG1 in the progression of CRC remains unclear. Methods: The expression of TUG1, microRNA-542-3p (miR-542-3p), and tribbles homolog 2 (TRIB2) in CRC tissues and cells (LoVo and HCT116) were detected by quantitative real-time PCR (qRT-PCR). Methyl thiazolyl tetrazolium (MTT), transwell and flow cytometry assays were employed to evaluate the effects of TUG1 in CRC cells. The interaction between miR-542-3p and TUG1 or TRIB2 were verified by dual-luciferase reporter assay. A xenograft tumor model in nude mice was established to investigate the biological role of TUG1 in CRC in vivo. Results: TUG1 was increased in CRC tissues and cells (LoVo and HCT116) in contrast with adjacent normal tissues and normal intestinal mucous cells (CCC-HIE-2). Downregulation of TUG1 or TRIB2 suppressed the proliferation, migration, invasion, and induced apoptosis in CRC cells. And knockdown of TUG1 repressed tumor growth in vivo. Besides, overexpression of TRIB2 reversed the effects of TUG1 depletion on the progression of CRC. Meanwhile, TUG1 interacted with miR-542-3p and TRIB2 was a target of miR-542-3p. Furthermore, miR-542-3p knockdown or TRIB2 overexpression partly reversed the suppression effect of TUG1 depletion on the Wnt/β-catenin pathway. Conclusions: TUG1 served as a tumor promoter, impeded the progression of CRC by miR-542-3p/TRIB2 axis to inactivate of Wnt/β-catenin pathway, which providing a novel target for CRC treatment.
1 January 2012 in Frontiers in Genetics
Haplotype analysis has been increasingly used to study the genetic basis of human diseases, but models for characterizing genetic interactions between haplotypes from different chromosomal regions have not been well developed in the current literature. In this article, we describe a statistical model for testing haplotype-haplotype interactions for human diseases with a case-control genetic association design. The model is formulated on a contingency table in which cases and controls are typed for the same set of molecular markers. By integrating well-established quantitative genetic principles, the model is equipped with a capacity to characterize physiologically meaningful epistasis arising from interactions between haplotypes from different chromosomal regions. The model allows the partition of epistasis into different components due to additive × additive, additive × dominance, dominance × additive, and dominance × dominance interactions. We derive the EM algorithm to estimate and test the effects of each of these components on differences in the pattern of genetic variation between cases and controls and, therefore, examine their role in the pathogenesis of human diseases. The method was further extended to investigate gene-environment interactions expressed at the haplotype level. The statistical properties of the models were investigated through simulation studies and its usefulness and utilization validated by analyzing the genetic association of sarcoidosis from a human genetics project.
28 March 2025 in IEEE Sensors Journal
System-level macro-models play a crucial role in the design and optimization of microelectromechanical systems (MEMS). However, accurately capturing coupling effects and nonlinearities is currently a significant challenge. To address the issues, a hybrid macro-modeling technique is developed by a combination of implicit condensation and conservative system Lagrange methods. For nonlinear electrostatic force, the electrostatic potential energy term in the Lagrange equation of the conservative system is obtained by fitting the capacitance function after a series of static simulations. Regarding stiffness estimation, polynomial stiffness terms are derived through implicit condensation method rather than relying on strain energy sampling, which is applicable to a variety of in-plane structures. Instead of calculating complex analytical formulations of squeeze and sliding film damping, computational fluid dynamics (CFD) numerical simulation is employed to determine the modal damping ratios, avoiding analytical estimation of complex geometries and enhancing the modeling automation. Using double-end fixed beam and capacitive accelerometer as examples, the effectiveness of the proposed macro-modeling technique is illustrated. Compared with full finite element simulation, the overall error of the macro-model is less than 1.6 %. System-level simulation and experimental results indicate that the error of accelerator sensitivity is less than 5.0 %, excluding the effects of parasitic capacitance. The technique benefits from being non-intrusive, which means that it can be implemented with most commercial finite element software without requiring access to finite element core code.
1 September 2026 in IEEE Sensors Journal