Hannes Harter

Hannes Harter

Auto-generated profile, based on publicly available information

Hannes Harter

Chair of Energy Efficient and Sustainable Design and Building, Technical University of Munich (TUM), Arcisstr. 21, Munich, 80333 Bavaria, Germany

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Energy and Buildings
Verified
Journal Article
Closed access
VWVerena Weiler
Verena Weiler
HHHannes Harter
Hannes Harter
UEUrsula Eicker
Ursula Eicker

1 February 2020 in Energy and Buildings
Verified
Journal Article
Closed access
HHHannes Harter
Hannes Harter
MSManav Mahan Singh
Manav Mahan Singh
PSPatricia Schneider-Marin
Patricia Schneider-Marin
WLWerner Lang
Werner Lang
PGPhilipp Geyer
Philipp Geyer

26 March 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
PSPatricia Schneider-Marin
Patricia Schneider-Marin
HHHannes Harter
Hannes Harter
Konstantin TkachukKonstantin Tkachuk
Konstantin Tkachuk
WLWerner Lang
Werner Lang
With current efforts to increase energy efficiency and reduce greenhouse gas (GHG) emissions of buildings in the operational phase, the share of embedded energy (EE) and embedded GHG emissions is increasing. In early design stages, chances to influence these factors in a positive way are greatest, but very little and vague information about the future building is available. Therefore, this study introduces a building information modeling (BIM)-based method to analyze the contribution of the main functional parts of buildings to find embedded energy demand and GHG emission reduction potentials. At the same time, a sensitivity analysis shows the variance in results due to the uncertainties inherent in early design to avoid misleadingly precise results. The sensitivity analysis provides guidance to the design team as to where to strategically reduce uncertainties in order to increase precision of the overall results. A case study shows that the variability and sensitivity of the results differ between environmental indicators and construction types (wood or concrete). The case study contribution analysis reveals that the building’s structure is the main contributor of roughly half of total GHG emissions if the main structural material is reinforced concrete. Exchanging reinforced concrete for a wood structure reduces total GHG emissions by 25%, with GHG emissions of the structure contributing 33% and windows 30%. Variability can be reduced systematically by first reducing vagueness in geometrical and technical specifications and subsequently in the amount of interior walls. The study shows how a simplified and fast BIM-based calculation provides valuable guidance in early design stages.

11 April 2023 in Journal of Cleaner Production
Verified
Journal Article
Closed access
HHHannes Harter
Hannes Harter
BWBruno Willenborg
Bruno Willenborg
WLWerner Lang
Werner Lang
TKThomas Kolbe
Thomas Kolbe

27 March 2020 in Journal of Information Technology in Construction
Verified
Journal Article
Open access
PDF file
JAJimmy Abualdenien
Jimmy Abualdenien
PSPatricia Schneider-Marin
Patricia Schneider-Marin
ZZZahedi Zahedi
Zahedi Zahedi
HHHannes Harter
Hannes Harter
HEHannah Exner
Hannah Exner
MSMartina Schnellenbach-Held
Martina Schnellenbach-Held
The early stages of building design involve the consideration of different design variants and their assessment regarding various performance criteria including energy consumption and costs. During the design process, the involved experts from different disciplines frequently exchange building information to develop a design that satisfies the project’s requirements and objectives. In the course of this iterative process, the building design evolves throughout multiple refinement stages. At the same time, different variants are developed. In BIM-based projects, the maturity of the design information provided by the model is expressed by the notion of Level of development (LOD). So far, however, there is no method to formally define the information requirements of a LOD. In particular, there are no means for expressing the uncertainty involved with the provided information. By contrast, despite the insufficient information available in early design stages, a BIM model appears precise and certain. This situation leads to false assumptions and model evaluations, for example, in the case of energy efficiency calculations or structural analysis. Hence, this paper presents an overview of a set of approaches that were developed to alleviate and preserve the consistency of the designed solutions. The approach includes the development of a multi-LOD meta-model, which allows one to explicitly describe the LOD requirements of each building component type incorporating the possible uncertainties, e.g. concerning the building dimensions. On the basis of this multi-LOD model, methods for evaluating a building design’s performance regarding the building’s structure and life cycle energy performance are proposed that take the defined uncertainties into account. To support the management of design variants in one consistent model, a graph-based approach is introduced. Finally, a minimized communication protocol is described to facilitate the workflow and communicate the evaluation results for supporting the decision-making process.

1 February 2017 in Building and Environment
Verified
Journal Article
Closed access
HHHannes Harter
Hannes Harter
VWVerena Weiler
Verena Weiler
UEUrsula Eicker
Ursula Eicker