Werner Lang

Werner Lang

Auto-generated profile, based on publicly available information

Werner Lang

Technical University of Munich

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in Mitigation and Adaptation Strategies for Global Change
Verified
Journal Article
Open access
PDF file
CGChristian Göpfert
Christian Göpfert
CWChristine Wamsler
Christine Wamsler
WLWerner Lang
Werner Lang
Cities are key actors in reducing both the causes of climate change (mitigation) and its impact (adaptation), and many have developed separate mitigation and adaptation strategies and measures. However, in order to maximize outcomes, both scholars and practitioners are increasingly calling for more integrated and synergetic approaches. Unfortunately, related research remains scarce and fragmented, and there is a lack of systematic investigation into the necessary institutional conditions and processes. Against this background, this paper develops a framework to assess and support the joint institutionalization of climate adaptation and mitigation—here called adaptigation—in city administrations. This pioneering framework draws upon four key features of bureaucracies: organizational structure, visions and goals, actors, and technology and tools. Illustrated by pilot applications to the cities of Würzburg (Germany) and Mwanza (Tanzania), the framework provides a robust basis for future research, policy recommendations, and the development of context-specific guidelines for national and local decision-makers and officials. It highlights the importance of (i) clearly defined procedures for the implementation of adaptigation into urban planning processes (e.g., with the active involvement of stakeholders in the form of working groups or roundtable discussions), (ii) locally relevant goals and visions, established in collaboration with stakeholders, and (iii) the creation of mitigation and adaptation structures that are supported by the appropriate level of human resources, both within and outside city administrations. In this context, global, supranational, and national institutions play an important role in supporting institutionalization by providing targeted funding and promoting adaptigation, which requires the development of integrated goals, visions, and legislation.

26 March 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
PSPatricia Schneider-Marin
Patricia Schneider-Marin
HHHannes Harter
Hannes Harter
Konstantin TkachukKonstantin Tkachuk
Konstantin Tkachuk
WLWerner Lang
Werner Lang
With current efforts to increase energy efficiency and reduce greenhouse gas (GHG) emissions of buildings in the operational phase, the share of embedded energy (EE) and embedded GHG emissions is increasing. In early design stages, chances to influence these factors in a positive way are greatest, but very little and vague information about the future building is available. Therefore, this study introduces a building information modeling (BIM)-based method to analyze the contribution of the main functional parts of buildings to find embedded energy demand and GHG emission reduction potentials. At the same time, a sensitivity analysis shows the variance in results due to the uncertainties inherent in early design to avoid misleadingly precise results. The sensitivity analysis provides guidance to the design team as to where to strategically reduce uncertainties in order to increase precision of the overall results. A case study shows that the variability and sensitivity of the results differ between environmental indicators and construction types (wood or concrete). The case study contribution analysis reveals that the building’s structure is the main contributor of roughly half of total GHG emissions if the main structural material is reinforced concrete. Exchanging reinforced concrete for a wood structure reduces total GHG emissions by 25%, with GHG emissions of the structure contributing 33% and windows 30%. Variability can be reduced systematically by first reducing vagueness in geometrical and technical specifications and subsequently in the amount of interior walls. The study shows how a simplified and fast BIM-based calculation provides valuable guidance in early design stages.

3 November 2022 in Building and Environment
Verified
Journal Article
Closed access
CZChujun Zong
Chujun Zong
MMManuel Margesin
Manuel Margesin
JSJohannes Staudt
Johannes Staudt
FDFatma Deghim
Fatma Deghim
WLWerner Lang
Werner Lang

5 March 2019 in Sustainability
Verified
Journal Article
Open access
PDF file
SYShi Yin
Shi Yin
WLWerner Lang
Werner Lang
YXYiqiang Xiao
Yiqiang Xiao
ZXZhao Xu
Zhao Xu
Traditional shophouse neighbourhoods (TSNs) in southern China respond well to the local hot and humid climate through proper street configurations and the integration of different shading strategies. Investigating the impact of shading strategies and configurations in TSNs on outdoor thermal comfort is valuable for guiding current urban design. Three street canyons in a TSN of Guangzhou with different shading strategies were selected as basic cases for microclimatic measurement in the summer season, i.e., alleys, streets with arcade for pedestrians, and streets with high-density greenery. After validating their simulation models in ENVI-met, five groups of parametric simulations were generated by varying the canyon aspect ratio (CHW), the canyon axis orientation, arcade proportion (AHW), and the tree-covered area (TCA). Using the physiological equivalent temperature (PET) to assess the above results, the correlative impact of different variations on pedestrian’s thermal comfort and their corresponding favourable ranges are summarized. The findings suggest that: (a) only in alleys and arcade streets, the pedestrian-level thermal comfort was significantly influenced by canyon axis orientation. (b) The thermal stress for pedestrians increased dramatically when the CHW was lower than 1.5 in alleys and 0.78 in boulevards (in TCA = 89%), while the CHW higher than 1 indicated a remarkable reduction on the PET for pedestrians in arcades. (c) The pedestrians started losing the protection from shading strategy to thermal stress when the AHW was higher than 1.33 (in canyon with CHW = 1) or the TCA was lower than 33% (in canyon with CHW = 0.78).

11 April 2023 in Journal of Cleaner Production
Verified
Journal Article
Closed access
HHHannes Harter
Hannes Harter
BWBruno Willenborg
Bruno Willenborg
WLWerner Lang
Werner Lang
TKThomas Kolbe
Thomas Kolbe

1 January 2022 in Building and Environment
Verified
Journal Article
Closed access
FBFarzan Banihashemi
Farzan Banihashemi
MWManuel Weber
Manuel Weber
WLWerner Lang
Werner Lang