Marcus C. J. de Boer

Marcus C. J. de Boer

Auto-generated profile, based on publicly available information

Marcus C. J. de Boer

RAM—Robotics and Mechatronics, University of Twente, Enschede, The Netherlands

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2025 in Applied Physics Reviews
Verified
Journal Article
Open access
MBMarcus C. J. de Boer
Marcus C. J. de Boer
LLLeendert-Jan W. Ligtenberg
Leendert-Jan W. Ligtenberg
IMIris Mulder
Iris Mulder
CGConstantinos Goulas
Constantinos Goulas
AKAnke Klingner
Anke Klingner
IKIslam S. M. Khalil
Islam S. M. Khalil
This study investigates the efficacy of an untethered magnetic robot (UMR) for wireless mechanical and hybrid blood clot removal in ex vivo tissue environments. By integrating x-ray-guided wireless manipulation with UMRs, we aim to address challenges associated with precise and controlled blood clot intervention. The untethered nature and size of these robots enhance maneuverability and accessibility within complex vascular networks, potentially improving clot removal efficiency. We explore mechanical fragmentation, chemical lysis, and hybrid dissolution techniques that combine mechanical fragmentation with chemical lysis, highlighting their potential for targeted and efficient blood clot removal. Through experimental validation using an ex vivo endovascular thrombosis model within the iliac artery of a sheep, we demonstrate direct revascularization of a 13-mm-long, 1-day-old blood clot positioned inside the left common iliac artery. This was achieved by deploying a UMR into the abdominal aorta within 15 min. Additionally, both mechanical fragmentation and hybrid dissolution achieve a greater volume rate of change compared to no intervention (control) and chemical lysis alone. Mechanical fragmentation exhibits clot removal with a median of 0.87 mm3/min and a range of 2.81 mm3/min, while the hybrid approach demonstrates slower but more consistent clot removal, with a median of 0.45 mm3/min and a range of 0.23 mm3/min.

11 August 2025 in Nonlinear Dynamics
Verified
Journal Article
Open access
PDF file
LJLuuc de Jongh
Luuc de Jongh
AKAnke Klingner
Anke Klingner
LLLeendert-Jan W. Ligtenberg
Leendert-Jan W. Ligtenberg
MBMarcus C. J. de Boer
Marcus C. J. de Boer
JKJaap van der Kooij
Jaap van der Kooij
IKIslam S. M. Khalil
Islam S. M. Khalil
In confined environments, the propulsion speed of torque-driven helical untethered magnetic robots (UMRs) depends on vessel diameter and helical pitch. This phenomenon likely affects the swimming speed of these robots when navigating in vivo within blood vessels. Achieving a consistent swimming speed across a range of vessel diameters is therefore essential for precise control of UMRs. With this goal, we investigate how vessel diameter and helical pitch influence UMR propulsion to identify optimal robot designs. UMRs from two groups–fixed length (FL) and fixed wave (FW)–were analyzed. In the FW group, longer robots achieved higher speeds in larger vessels due to better vessel guidance, whereas shorter robots performed best in medium-sized vessels. The FL group showed peak speeds at intermediate normalized wavenumbers ( $$\nu \approx 1$$ ν ≈ 1 to 1.8), significantly influenced by robot geometry and vessel confinement. Normalized wavenumber affected swimming speed and stability, with maximum efficiency at $$\nu \approx 1$$ ν ≈ 1 and stability increasing with higher wavenumbers. Swimming performance was modeled using Stokeslets method and additional effects were considered by correction factors to improve agreement of experimental and modeling results. Ex vivo tests under physiological conditions demonstrated clear performance differences between robust (FL-9 ( $$\nu =2.3$$ ν = 2.3 ), FW-5 ( $$\nu =2$$ ν = 2 )) and unstable swimmers, with robust designs showing consistent correlation between phantom and ex vivo trials. Unstable designs exhibited unpredictable behavior, emphasizing the importance of specific design parameters for stability and maneuverability. These findings highlight critical design factors–such as the normalized wavenumber, body length, and degree of vessel confinement–that are essential for enhancing UMR propulsion efficiency and control consistency, which are fundamental for successful navigation in targeted vascular biomedical applications.