16 November 2023 in Russian Bulletin of Otorhinolaryngology
The clinical protocol of audiological assessment in infants was prepared by the workgroup of Russian pediatric audiologists from different regions. The goal of the protocol is unification approaches to audiological diagnosis of the infants. The protocol has been developed according the evidence based medicine principles, by reviewing current scientific publications on the topic and taking into account the order of providing medical services and other clinical practice guidelines. When direct evidence was not available, both indirect evidence and consensus practice were considered in making recommendations. This guideline is not intended to serve as a standard to dictate precisely how the child should be diagnosed. This guideline is meant to provide the evidence base from which the clinician can make individualized decisions for each patient. The first part of the protocol covers following sections: equipment, staff requirements, timing of the diagnostics, case history and risk factors, preparing the child for the appointment, sedation and general anesthesia, otoscopy, tympanometry and acoustic reflex, otoacoustic emissions, skin preparing, electrode montage, choosing the stimulators, auditory brainstem responses on broadband and narrow-band stimuli, on bone conducted stimuli, auditory steady-state responses, masking, combined correction factors.
28 December 2023 in Russian Bulletin of Otorhinolaryngology
This is the second part of the previously published clinical protocol of audiological assessment in infants. The goal of the protocol is unification approaches to audiological diagnosis of the infants. The following sections were included in the second part of the protocol: behavioral testing in infants, testing sequence, duration of the examination and necessity in follow-up, hearing assessment in special cases (premature children, children with congenital infections, after meningitis, with external ear abnormalities, single-sided deafness, with hydrocephalus and shunts, with auditory neuropathy spectrum disorder, with mild hearing loss and otitis media with effusion), medical report.
28 December 2023 in Russian Bulletin of Otorhinolaryngology
Objective. The research was aimed to assess speech intelligibility in adults after the new coronavirus infection (COVID-19), state of peripheral and central parts of auditory system and cognitive functions. Material and methods. 26 people complaining about hearing loss, poor speech intelligibility and/or tinnitus after COVID-19 were examined. All the patients underwent the basic audiological assessment before COVID-19. Extended testing in patients after COVID-19 included: pure tone audiometry, impedancemetry, speech audiometry in quiet and noise (evaluation of monosyllabic words intelligibility and the Russian matrix sentence test RuMatrix), the alternating binaural speech test, the dichotic digits test and the Montreal Cognitive Assessment (MoCA). Results. The most significant deviations from the normative values were obtained in the RuMatrix test and the dichotic digits test that may be due to both central auditory processing disorder and memory impairment. Low MoCA scores were obtained in 62% of patients. Conclusion. Deterioration of speech intelligibility after COVID-19 was revealed, both in patients with hearing loss and with normal hearing that corresponded to their complaints. It may be caused by central auditory disorder, memory impairment or cognitive status lesion. The correlation found between the results of the RuMatrix test in noise and the severity of the COVID-19 may indicate the impact of the virus on the auditory cortex.
29 December 2025 in Folia Otorhinolaryngologiae et Pathologiae Respiratoriae
ПМПасюта Сергей Михайлович
+2
BACKGROUND: Opportunities for early detection of hearing loss in adults remain limited due to the absence of screening programs, low accessibility of audiological care, and insufficient public awareness regarding hearing health. Pure-tone audiometry, the basic method for assessing hearing acuity, requires expensive equipment and specially trained personnel. Smartphone-based audiometry, offered by several manufacturers as a simple and cost-effective screening tool, allows assessment of pure-tone hearing thresholds only and does not reflect the ability to understand speech in noise. However, contemporary clinical practice increasingly requires evaluation of functional capacity to maintain verbal communication in acoustically unfavorable environments, including competing speech, broadband noise, and reverberation. AIM: To assess the technical performance of a pilot prototype of the tonal-speech screening audiometer SURDOSCOPE® for rapid diagnosis of hearing impairment in adults. METHODS: An automated tonal-speech screening audiometer SURDOSCOPE® based on a tablet platform was proposed for use. The device enables self-assessment of pure-tone thresholds and speech intelligibility in noise (words and phrases presented against pink noise at a fixed signal-to-noise ratio), using speech synthesis and recognition technologies. Between 2023 and 2025, 124 examinations were performed using different algorithms in 31 participants aged 24–80 years (random sample). The audiometer was used in an automated tonal-speech screening mode in a self-assessment format without medical staff involvement. Conventional pure-tone audiometry performed using a clinical audiometer Maico MA42 served as the reference method. RESULTS: A high level of agreement was established between hearing thresholds obtained with the screening audiometer and those measured with the clinical audiometer (mean difference not exceeding ± 5 dB HL). The SURDOSCOPE® audiometer also demonstrated high efficiency in rapid self-assessment of speech intelligibility in noise. The total duration of tonal-speech screening testing averaged 10.5 ± 5.7 minutes, whereas conventional pure-tone audiometry alone required 16.3 ± 2.1 minutes. Criteria were established to determine the need for further audiological evaluation. CONCLUSION: Automated tablet-based tonal-speech screening audiometry provides accurate and reproducible self-assessment of pure-tone hearing thresholds and speech intelligibility in noise, remarkably reducing examination time and enabling appropriate referral of patients for further evaluation by an audiologist-otolaryngologist.
15 July 2025 in Pediatric pharmacology
Congenital cytomegalovirus infection (cCMV) can cause a wide range of diseases in newborns, it is most often associated with sensorineural hearing loss (SNHL). cCMV is the leading cause of non-hereditary SNHL (up to 25% of all SNHL cases in). SNHL can be congenital and can have late-onset (up to 50% of cases) up to school age, it determines the risk of its late diagnosis. Children with cCMV should be referred for diagnostic examination even after successfully passed newborn hearing screening. The child remains under the dynamic audiologist’s follow-up, if the diagnostic examination results are normal. Management of children with confirmed hearing loss includes early auditory prosthesis; in cases of severe hearing loss and ineffective auditory prosthesis — cochlear implantation, speech-language therapy, parents training and informing.
1 March 2026 in Russian Bulletin of Otorhinolaryngology
Pure tone audiometry (PTA) is the crucial method for hearing function assessment in adults. Auditory brainstem response (ABR) and auditory steady-state response (ASSR) are mainly registered in adults only if objective hearing evaluation is required, in particular in cases of expertise. Objective. To compare thresholds obtained by PTA and ASSR at speech frequencies; to analyze causes of possible thresholds discrepancies. Material and methods. Totally 244 patients aged from 18 to 104 were examined in two clinics. After basic ENT check-up air and bone conduction PTA at standard frequencies was run, next — ABR and ASSR registration. Results. Correlation coefficient between ASSR and PTA thresholds was 0.7—0.71 at frequencies 500—1000 Hz and 0.54—0.58 at frequencies 2000—4000 Hz. No significant difference was revealed between thresholds obtained for right and left ears and between results obtained in two clinics. The least discrepancy between PTA and ASSR thresholds (0.8—11.8 dB) was obtained at 1000 Hz, the maximum one (13.7—15.1 dB) was got at 4000 Hz. The significant strong correlation (r=0.7) between PTA and ASSR thresholds discrepancy degree at frequencies 2000 to 4000 Hz and slope audiogram type was revealed. The weak correlation between PTA and ASSR thresholds discrepancy extent and hearing loss degree and patient’s age was got. Conclusion. ASSR registration reliability in adults was shown and the method could be applied in case if either PTA is not accessible or PTA results are invalid. PTA and ASSR thresholds discrepancies were revealed in patients with slope audiometry types, high frequency ASSR thresholds might be better than PTA ones.