Marco D'ALonzo

Marco D'ALonzo

Auto-generated profile, based on publicly available information

Marco D'ALonzo

Research Unit of Neurophysiology and Neuroengineering of Human-Technology Interaction (NeXTlab), Università Campus Bio-Medico di Roma, Rome, Italy

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
ANAlessia Noccaro
Alessia Noccaro
AMA. Mioli
A. Mioli
MDM. D'ALonzo
M. D'ALonzo
MPMattia Pinardi
Mattia Pinardi
GPG. Di Pino
G. Di Pino
Domenico FormicaDomenico Formica
Domenico Formica
Objective: This article presents the development and validation of a new robotic system for Transcranial Magnetic Stimulation (TMS), characterized by a new control approach, and an ad-hoc calibration methodology, specifically devised for the TMS application. Methods: The robotic TMS platform is composed of a 7 dof manipulator, controlled by an impedance control, and a camera-based neuronavigation system. The proposed calibration method was optimized on the workspace useful for the specific TMS application (spherical shell around the subject's head), and tested on three different hand-eye and robot-world calibration algorithms. The platform functionality was tested on six healthy subjects during a real TMS procedure, over the left primary motor cortex. Results: employing our method significantly decreases ( $p< 0.001$ ) the calibration error by 34% for the position and 19% for the orientation. The robotic TMS platform achieved greater orientation accuracy than the expert operators, significantly reducing orientation errors by 46% ( $p< 0.001$ ). No significant differences were found in the position errors and in the amplitude of the motor evoked potentials (MEPs) between the robot-aided TMS and the expert operators. Conclusion: The proposed calibration represents a valid method to significantly reduce the calibration errors in robot-aided TMS applications. Results showed the efficacy of the proposed platform (including the control algorithm) in administering a real TMS procedure, achieving better coil positioning than expert operators, and similar results in terms of MEPs. Significance: This article spotlights how to improve the performance of a robotic TMS platform, providing a reproducible and low-cost alternative to the few devices commercially available.

7 July 2021 in Journal of Neurophysiology
Verified
Journal Article
Open access
PDF file
AZAndrea Zangrandi
Andrea Zangrandi
MDMarco D’alonzo
Marco D’alonzo
CCChristian Cipriani
Christian Cipriani
GPGiovanni Di Pino
Giovanni Di Pino
Sensory feedback is pivotal for a proficient dexterity of the hand. By modulating the grip force in function of the quick and not completely predictable change of the load force, grabbed objects are prevented to slip from the hand. Slippage control is an enabling achievement to all manipulation abilities. However, in hand prosthetics, the performance of even the most innovative research solutions proposed so far to control slippage remain distant from the human physiology. Indeed, slippage control involves parallel and compensatory activation of multiple mechanoceptors, spinal and supraspinal reflexes, and higher-order voluntary behavioral adjustments. In this work, we reviewed the literature on physiological correlates of slippage to propose a three-phases model for the slip sensation and reaction. Furthermore, we discuss the main strategies employed so far in the research studies that tried to restore slippage control in amputees. In the light of the proposed three-phase slippage model and from the weaknesses of already implemented solutions, we proposed several physiology-inspired solutions for slippage control to be implemented in the future hand prostheses. Understanding the physiological basis of slip detection and perception and implementing them in novel hand feedback system would make prosthesis manipulation more efficient and would boost its perceived naturalness, fostering the sense of agency for the hand movements.

9 September 2023 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
EPErmanno Donato Papaleo
Ermanno Donato Papaleo
MDMarco D’alonzo
Marco D’alonzo
FFFrancesca Fiori
Francesca Fiori
VPValeria Piombino
Valeria Piombino
EFEmma Falato
Emma Falato
GPGiovanni Di Pino
Giovanni Di Pino
Proprioception plays a key role in moving our body dexterously and effortlessly. Nevertheless, the majority of investigations evaluating the benefits of providing supplemental feedback to prosthetics users focus on delivering touch restitution. These studies evaluate the influence of touch sensation in an attempt to improve the controllability of current robotic devices. Contrarily, investigations evaluating the capabilities of proprioceptive supplemental feedback have yet to be comprehensively analyzed to the same extent, marking a major gap in knowledge within the current research climate. The non-invasive strategies employed so far to restitute proprioception are reviewed in this work. In the absence of a clearly superior strategy, approaches employing vibrotactile, electrotactile and skin-stretch stimulation achieved better and more consistent results, considering both kinesthetic and grip force information, compared with other strategies or any incidental feedback. Although emulating the richness of the physiological sensory return through artificial feedback is the primary hurdle, measuring its effects to eventually support the integration of cumbersome and energy intensive hardware into commercial prosthetic devices could represent an even greater challenge. Thus, we analyze the strengths and limitations of previous studies and discuss the possible benefits of coupling objective measures, like neurophysiological parameters, as well as measures of prosthesis embodiment and cognitive load with behavioral measures of performance. Such insights aim to provide additional and collateral outcomes to be considered in the experimental design of future investigations of proprioception restitution that could, in the end, allow researchers to gain a more detailed understanding of possibly similar behavioral results and, thus, support one strategy over another.

22 February 2021 in Cerebral Cortex
Verified
Journal Article
Open access
PDF file
DRDaniele Romano
Daniele Romano
AMAlessandro Mioli
Alessandro Mioli
MDMarco D’aLonzo
Marco D’aLonzo
AMAngelo Maravita
Angelo Maravita
VLVincenzo Di Lazzaro
Vincenzo Di Lazzaro
GPGiovanni Di Pino
Giovanni Di Pino
Motor planning and execution require a representational map of our body. Since the body can assume different postures, it is not known how it is represented in this map. Moreover, is the generation of the motor command favored by some body configurations? We investigated the existence of a centrally favored posture of the hand for action, in search of physiological and behavioral advantages due to central motor processing. We tested two opposite hand pinch grips, equally difficult and commonly used: forearm pronated, thumb-down, index-up pinch against the same grip performed with thumb-up. The former revealed faster movement onset, sign of faster neural computation, and faster target reaching. It induced increased corticospinal excitability, independently on pre-stimulus tonic muscle contraction. Remarkably, motor excitability also increased when thumb-down pinch was only observed, imagined, or prepared, actually keeping the hand at rest. Motor advantages were independent of any concurrent modulation due to somatosensory input, as shown by testing afferent inhibition. Results provide strong behavioral and physiological evidence for a preferred hand posture favoring brain motor control, independently by somatosensory processing. This suggests the existence of a baseline postural representation that may serve as an a priori spatial reference for body–space interaction.

21 April 2022 in Open Research Europe
Verified
Journal Article
Open access
GPGiovanni Di Pino
Giovanni Di Pino
AMAlessandro Mioli
Alessandro Mioli
CAClaudia Altamura
Claudia Altamura
MDMarco D'ALonzo
Marco D'ALonzo
Background: The autonomic nervous system is the main determinant of the blood flow directed towards a body part, and it is tightly connected to the representation of the body in the brain; would the experimental modulation of the sense of limb ownership affect its blood perfusion? Methods: In healthy participants, we employed the rubber hand illusion paradigm to modulate limb ownership while we monitored the brachial artery blood flow and resistance index within the investigated limb. Results: In all conditions with brush-stroking, we found an initial drop in the blood flow due to tactile stimulation. Subsequently, in the illusion condition (where both the rubber and real hand synchronous brush-stroking were present), the blood flow rose significantly faster and reached significantly higher values. Moreover, the increase in blood flow correlated with the extent of embodiment as measured by questionnaires and correlated negatively with the change of peripherical vascular resistance. Conclusions: These findings suggest that modulating the representation of a body part impacts its blood perfusion.

16 October 2025 in Clinical Neurophysiology
Verified
Journal Article
Open access
EFEmma Falato
Emma Falato
FRFederico Ranieri
Federico Ranieri
GMGabriella Musumeci
Gabriella Musumeci
MDMarco D’ALonzo
Marco D’ALonzo
FCFioravante Capone
Fioravante Capone
VLVincenzo Di Lazzaro
Vincenzo Di Lazzaro
Major upper limb amputation (mULA) induces neuroplastic changes that can impact neurorehabilitation and prosthetic control. Previous literature suggested heightened corticospinal excitability (CE) in the hemisphere contralateral to the amputation (CLH). This interhemispheric imbalance in CE might represent a maladaptive process. We aimed to assess baseline CE in individuals with chronic mULA and the acute effects of continuous theta burst stimulation (cTBS) applied to the primary motor cortex (M1) contralateral to the amputation. Thirteen adults with chronic transradial or transhumeral mULA underwent electrophysiological assessments before and after unilateral cTBS. CE was measured through motor-evoked potential (MEP) amplitudes at baseline, 5 and 10 min post-stimulation. Linear mixed models assessed the effects of Hemisphere (contralateral vs ipsilateral), Time (baseline, 5, 10 min), and their interaction. Group-level analyses indicated higher MEP amplitudes in the CLH compared with the ipsilateral hemisphere. cTBS was associated with a transient reduction of MEP amplitudes in the stimulated CLH at 5 minutes, with partial recovery at 10 minutes, leading to a temporary attenuation of interhemispheric asymmetry. These findings suggest that cTBS may transiently modulate CE in chronic mULA, with effects that appear restricted to the stimulated hemisphere. This study provides preliminary evidence of interhemispheric asymmetry in CE after mULA and indicates that cTBS could represent a potential tool to modulate it. Further studies are needed to establish robustness and clinical relevance.