29 May 2007 in Magnetic Resonance in Medicine
The reconstruction of artifact‐free images from radially encoded MRI acquisitions poses a difficult task for undersampled data sets, that is for a much lower number of spokes in k‐space than data samples per spoke. Here, we developed an iterative reconstruction method for undersampled radial MRI which (i) is based on a nonlinear optimization, (ii) allows for the incorporation of prior knowledge with use of penalty functions, and (iii) deals with data from multiple coils. The procedure arises as a two‐step mechanism which first estimates the coil profiles and then renders a final image that complies with the actual observations. Prior knowledge is introduced by penalizing edges in coil profiles and by a total variation constraint for the final image. The latter condition leads to an effective suppression of undersampling (streaking) artifacts and further adds a certain degree of denoising. Apart from simulations, experimental results for a radial spin‐echo MRI sequence are presented for phantoms and human brain in vivo at 2.9 T using 24, 48, and 96 spokes with 256 data samples. In comparison to conventional reconstructions (regridding) the proposed method yielded visually improved image quality in all cases. Magn Reson Med 57:1086–1098, 2007.
25 March 2015 in Magnetic Resonance in Medicine
16 December 2016 in Journal of Magnetic Resonance Imaging
24 August 2008 in Magnetic Resonance in Medicine
The use of parallel imaging for scan time reduction in MRI faces problems with image degradation when using GRAPPA or SENSE for high acceleration factors. Although an inherent loss of SNR in parallel MRI is inevitable due to the reduced measurement time, the sensitivity to image artifacts that result from severe undersampling can be ameliorated by alternative reconstruction methods. While the introduction of GRAPPA and SENSE extended MRI reconstructions from a simple unitary transformation (Fourier transform) to the inversion of an ill‐conditioned linear system, the next logical step is the use of a nonlinear inversion. Here, a respective algorithm based on a Newton‐type method with appropriate regularization terms is demonstrated to improve the performance of autocalibrating parallel MRI—mainly due to a better estimation of the coil sensitivity profiles. The approach yields images with considerably reduced artifacts for high acceleration factors and/or a low number of reference lines. Magn Reson Med, 2008.
1 October 2011 in Investigative Radiology
Objective: To compare free-breathing radially sampled 3D fat suppressed T1-weighted gradient-echo acquisitions (radial volumetric interpolated breath-hold examination [VIBE]) with breath-hold (BH) and free-breathing conventional (rectilinearly sampled k-space) VIBE acquisitions for postcontrast imaging of the liver. Materials and Methods: Eighteen consecutive patients referred for clinically indicated liver magnetic resonance imaging were imaged at 3 T. Three minutes after a single dose of gadolinium contrast injection, free-breathing radial VIBE, BH VIBE, and free-breathing VIBE with 4 averages were acquired in random order with matching sequence parameters. Radial VIBE was acquired with the “stack-of-stars” scheme, which uses conventional sampling in the slice direction and radial sampling in-plane. All image data sets were evaluated independently by 3 radiologists blinded to patient and sequence information. Each reader scored the following parameters: overall image quality, respiratory motion artifact, pulsation artifact, liver edge sharpness, and hepatic vessel clarity using a 5-point scale, with the highest score indicating the most optimum examination. Mixed model analysis of variance was used to compare sequences in terms of each measure of image quality. Results: When scores were averaged over readers, there was no statistically significant difference between radial VIBE and BH VIBE regarding overall image quality (P = 0.1015), respiratory motion artifact (P = 1.0), and liver edge sharpness (P = 0.2955). Radial VIBE demonstrated significantly lower pulsation artifact (P < 0.0001), but had lower hepatic vessel clarity (P = 0.0176), when compared with BH VIBE. Radial VIBE had significantly higher image quality scores for all parameters when compared with free-breathing VIBE (P < 0.0001). Acquisition time for BH VIBE was 14 seconds and that of free-breathing radial VIBE and conventional VIBE with multiple averages was 56 seconds each. Conclusion: Radial VIBE can be performed during free breathing for contrast-enhanced imaging of the liver with comparable image quality to BH VIBE. However, further work is necessary to shorten the acquisition time to perform dynamic imaging.
19 March 2014 in Magnetic Resonance in Medicine
Purpose: Quantitative T2‐relaxation‐based contrast has the potential to provide valuable clinical information. Practical T2‐mapping, however, is impaired either by prohibitively long acquisition times or by contamination of fast multiecho protocols by stimulated and indirect echoes. This work presents a novel postprocessing approach aiming to overcome the common penalties associated with multiecho protocols, and enabling rapid and accurate mapping of T2 relaxation values.Methods: Bloch simulations are used to estimate the actual echo‐modulation curve (EMC) in a multi–spin‐echo experiment. Simulations are repeated for a range of T2 values and transmit field scales, yielding a database of simulated EMCs, which is then used to identify the T2 value whose EMC most closely matches the experimentally measured data at each voxel.Results: T2 maps of both phantom and in vivo scans were successfully reconstructed, closely matching maps produced from single spin‐echo data. Results were consistent over the physiological range of T2 values and across different experimental settings.Conclusion: The proposed technique allows accurate T2 mapping in clinically feasible scan times, free of user‐ and scanner‐dependent variations, while providing a comprehensive framework that can be extended to model other parameters (e.g., T1, B1+, B0, diffusion) and support arbitrary acquisition schemes. Magn Reson Med 73:809–817, 2015. © 2014 Wiley Periodicals, Inc.