Fault‐tolerant drives have been gaining increasing attention due to the need to enhance the reliability and robustness of electric drive systems, particularly for safety critical applications. However, in postfault control, it is often necessary to derate the machine, that is to reduce the torque and/or flux currents, to satisfy the current constraints of the power electronic devices. For induction motors, there are different approaches to quantify the current components in postfault operation while maintaining a stable operation within the current constraints. The efficiency enhancement of a faulted drive through flux current reduction is one of the methods reported in literature, however, the details of power components, that is, achievable torque and speed, are not addressed. This study broadly investigates the effect of flux and/or torque current partitioning on postfault capability of polyphase (three and more phases) induction machines in terms of achievable torque and speed. It is demonstrated that the magnetising inductance characteristics, which depend on the machine design and its power rating, have a profound effect on the choice of postfault current partitioning, and hence the machine performance. Theoretical discussion is supported with experimental verification using three‐phase and symmetrical six‐phase induction motors.
This paper presents the performance comparison for 2 types of Bedini SSG free energy generator. The Bedini SSG is one types of magnetic motor generators based on zero point technology created and demonstrated by John Bedini. This device acts as a self-battery charger. The study involved the construction and performance of the original Bedini Monopole Mechanical Oscillator SSG Energizer and 4-Pole Neodymium Magnet Bedini SSG. This type of free energy generator can be one of an alternative way to replace the non-renewable energy sources that will run out in future. In this paper, the Battery's Coefficient of Performance (COP) for both designs will be identified. Investigation and analysis were done for both types of Bedini SSG. It was found that the replication design can charge faster, had less power consumption and its COP improved by 8% compared to the original design.
1 September 2024 in International Journal of Power Electronics and Drive Systems (IJPEDS)
Electric bicycles (E-bikes) are becoming key to making transportation more eco-friendly, leading to cleaner air, and lower carbon emissions. The rising popularity of E-bikes calls for innovative battery charging solutions that cater to their specific needs, emphasizing faster charging, high energy efficiency, safety, compact design, smart features, and compliance with international standards. This paper reviews existing and new charging technologies for E-bikes, focusing on their design, charging processes, and safety features. It points out the issues with traditional chargers, such as their negative effects on power quality and grid stability, and introduces wireless power transfer (WPT) as a groundbreaking approach to E-bike charging. WPT enhances convenience by removing the need for physical cables and is seen as a step forward with the integration of power factor correction techniques for better efficiency and energy use. The discussion extends to the future of E-bike charging, exploring emerging technologies that could redefine electric transportation. The study aims to deepen the understanding of E-bike battery charging technologies, their challenges, and future directions, contributing to the advancement of E-bike technology.
1 June 2020 in International Journal of Power Electronics and Drive Systems (IJPEDS)
In this paper, a comparative performance analysis of bridgeless boost and bridgeless buck converter for Uninterruptable Power Supply (UPS) is presented. The performance of UPS application in terms of their efficiency is compared between the conventional diode bridge converter and both bridgeless converters. The input supply power quality is also been analysed by applying open and closed loop control techniques to the converter. The results show that the efficiency and the input supply quality of the bridgeless converters are significantly improved. UPS using bridgeless boost converter has better performance in all aspect compared to bridgeless buck converter. Aligned with that, the closed loop controller for the converter has also improved the efficiency and PF more than the open loop controller in performing the UPS system. All the analytical work was performed using PSIM software.
1 March 2025 in International Journal of Power Electronics and Drive Systems (IJPEDS)
Six-phase machine research has attracted a lot of attention lately, as seen by the large number of articles and case studies that have been written about it. Six-phase induction machines are prevalent due to their simplicity in construction. A fault-tolerance system is essential to guaranteeing machine operation that is both available and continuous in the event of a disruption or failure in the system. The operational topologies of dual three-phase (D3-IM) and symmetrical six-phase (S6-IM) induction machines were studied in this research. One open-phase fault (1OPF) is covered in the study, and different scenarios including the derating factor, neutral configuration, and maximum torque (MT) operational strategy are taken into account. Using MATLAB software, machine characteristics, machine equations, and Clarke's transformation show the fault-tolerant capability of each type of machine. Moreover, a MATLAB program is developed to assess post-fault voltage control limits, allowing for a comparison between current and voltage control limits. Simulated graph results depicting line-to-line voltages against synchronous and slip frequencies across all possible fault scenarios reveal distinct fault-tolerant capabilities between the two machine types. The comparative study shows that S6-IM offers better fault-tolerant capability than D3-IM based on both various synchronous and slip frequency approaches.
1 December 2024 in International Journal of Power Electronics and Drive Systems (IJPEDS)
This paper presents an adaptive linear neuron (Adaline) algorithm designed to extract resonance current from the supply current directly. It aims to reduce the computation burden while upholding efficacy in the extraction process. The approach involves establishing the primary power system, evaluating harmonic and resonance current impacts, formulating efficient extraction strategies based on current waveform characteristics, employing the Adaline algorithm for extraction, and constructing a single-phase shunt active power filter (SAPF) to address harmonic currents and parallel resonance effects. Comparative analysis demonstrates the Adaline algorithm’s precision in extracting current amplitudes pre- and post-SAPF implementation. However, observed disparities in extracted resonance current amplitude may stem from the algorithm’s limitations in capturing low-amplitude signals. While a gain adjustment effectively boosts amplitude. However, it introduces considerable ripple and inconsistency, likely linked to parallel resonance effects. Notably, the SAPF exhibits simultaneous harmonic compensation and resonance damping capabilities. Results affirm the SAPF’s effectiveness in reducing harmonic components across all frequencies, including resonance frequency. Furthermore, resonance damping is crucial for further improving SAPF performance and reducing resonance current. This results in significantly improved waveform quality and reduced total harmonic distortion (THD) and individual harmonic distortion (THDi) values of compensated supply current.