A. Mase

A. Mase

Auto-generated profile, based on publicly available information

A. Mase

Art, Science and Technology Center for Cooperative Research, Kyushu University, Kasuga 816-8580, Japan

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 September 2003 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
HPH. Park
H. Park
CCC. C. Chang
C. C. Chang
BDB. H. Deng
B. H. Deng
CDC. W. Domier
C. W. Domier
ADA. J. H. Donné
A. J. H. Donné
WZW-K. Zhang
W-K. Zhang
Significant advances in microwave and millimeter wave technology over the past decade have enabled the development of a new generation of imaging diagnostics for current and envisioned magnetic fusion devices. Prominent among these are microwave electron cyclotron emission imaging, microwave phase imaging interferometers, imaging microwave scattering, and microwave imaging reflectometer systems for imaging Te and ne fluctuations (both turbulent and coherent) and profiles (including transport barriers) on toroidal devices such as tokamaks, spherical tori, and stellarators. The diagnostic technology is reviewed, and typical diagnostic systems are analyzed. Representative experimental results obtained with these novel diagnostic systems are also presented.

1 January 1997 in Review of Scientific Instruments
Verified
Journal Article
Closed access
TTT. Tokuzawa
T. Tokuzawa
AMA. Mase
A. Mase
NON. Oyama
N. Oyama
AIA. Itakura
A. Itakura
TTT. Tamano
T. Tamano

1 January 1997 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
NON. Oyama
N. Oyama
AMA. Mase
A. Mase
TTT. Tokuzawa
T. Tokuzawa
KIK. Imamura
K. Imamura
AIA. Itakura
A. Itakura
KMK. Mizuno
K. Mizuno
A millimeter-wave two-dimensional imaging array has been fabricated in order to diagnose the plug-cell plasma of the GAMMA 10 tandem mirror. The heterodyne system with two separate sources enables the measurement of density and electron cyclotron emission (ECE) in one plasma shot. The interferometer successfully measures the time evolution of the axial and radial line-density profiles with phase resolution less than 1/200 fringe and spatial resolution of 16 mm in the vertical direction and 5 mm in the horizontal one. It is shown that the Abel-inverted density profiles are changed due to the injection of electron-cyclotron-resonance heating at the plug/barrier cells and central cell. The axial and radial dependence of the second-harmonic ECE emitted from hot electrons produced in barrier region is observed simultaneously. The fluctuation spectra of the ECE signals are compared with those obtained from the far-forward scattering diagnostic system.

1 January 1999 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
HHH. Hojo
H. Hojo
YKY. Kurosawa
Y. Kurosawa
AMA. Mase
A. Mase
Two-dimensional simulator models are presented for microwave diagnostics. The models assume the Maxwell wave equation coupled with the equation of plasma current density in a cold magnetized plasma, which can describe propagation, reflection, and cross polarization scattering of the ordinary and extraordinary modes. The effects of waveguide for the microwave launcher and wall boundary of the vacuum vessel are included in the models. The simulations of ultrashort-pulse reflectometry with the use of incident subcyclic ordinary modes in the models are performed to test the problem of density profile reconstruction.

1 January 2001 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
AMA. Mase
A. Mase
MOM. Ohashi
M. Ohashi
AYA. Yamamoto
A. Yamamoto
HNH. Negishi
H. Negishi
NON. Oyama
N. Oyama
AMA. Miura
A. Miura
Millimeter-wave imaging systems in the frequency range of 70–140 GHz have been developed for diagnostics of magnetically confined plasmas. The 70 GHz imaging system successfully measures time evolutions of both radial and axial profiles of line density and electron cyclotron emission (ECE) in a tandem mirror. The imaging system is being installed in Large Helical Device (LHD) at the National Institute for Fusion Science. In order to cover the frequency range of the second harmonic ECE on LHD, a new detector using monolithic microwave integrated circuit technology has been designed and fabricated. The detector consists of the integration of a receiving antenna, a down-converting mixer diode, and an intermediate frequency amplifier on a GaAs substrate chip. The heterodyne response up to 10 GHz was confirmed at 70–140 GHz. The optical system consisting of an ellipsoidal mirror and a flat mirror was designed by using a ray-tracing code and evaluated experimentally at 140 GHz.

1 July 2004 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Closed access
LBL G Bruskin
L G Bruskin
NON Oyama
N Oyama
AMA Mase
A Mase
KSK Shinohara
K Shinohara
YMY Miura
Y Miura