Maxim Ostras

Maxim Ostras

Auto-generated profile, based on publicly available information

Maxim Ostras

Russian Quantum Center, Moscow, Russia

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ARAlexandra Razorenova
Alexandra Razorenova
ABAnna Butorina
Anna Butorina
ESEkaterina Skidchenko
Ekaterina Skidchenko
MOMaxim Ostras
Maxim Ostras
AOAlexei Ossadtchi
Alexei Ossadtchi
NKNikolay Koshev
Nikolay Koshev

16 January 2026 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
OLOlesya Lutsenko
Olesya Lutsenko
DTDenis Taurenis
Denis Taurenis
PKPavel Kapralov
Pavel Kapralov
NKNikolay Koshev
Nikolay Koshev
MZMikhail N. Zharkov
Mikhail N. Zharkov
Gleb SukhorukovGleb Sukhorukov
Gleb Sukhorukov
This work presents a novel YIG-based gradientometer system specifically designed for high-performance magnetorelaxometry (MRX) applications. The two-channel impedance-based yttrium-iron garnet (IM-YIG) sensor achieves an exceptional magnetic field sensitivity of 10 pT/√Hz combined with ultrafast (less than 1 ms) dead time, enabling precise measurement of rapid magnetic particle relaxation dynamics. The gradiometric configuration provides effective common-mode interference rejection while maintaining a wide dynamic range essential for MRX studies. The developed system demonstrates several key advantages over traditional approaches: it operates at room temperature without requiring cryogenic infrastructure or complex optical components, significantly simplifying experimental setups while improving measurement stability, and works without magnetic shielded environment. Comprehensive testing with magnetic particle samples verified the system’s capability to reliably detect relaxation signals corresponding to iron masses as low as 50 ng. Furthermore, analysis of baseline stability suggests potential for even lower detection limits through optimized signal processing. The system’s robust performance and simplified architecture make it particularly suitable for deployment in resource-constrained environments where conventional SQUID or OPM systems would be impractical.

11 December 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
NKNikolay Koshev
Nikolay Koshev
PKPavel Kapralov
Pavel Kapralov
OLOlesya Lutsenko
Olesya Lutsenko
DTDenis Taurenis
Denis Taurenis
SESvetlana Evstigneeva
Svetlana Evstigneeva
PVPetr Vetoshko
Petr Vetoshko
Current MRX setups employ superconducting quantum interference devices (SQUIDs) or optically pumped magnetometers (OPMs). Both of these sensors are known for high sensitivity but also associated with various constraints such as need for cryogenic cooling (SQUIDs) or complex optical systems (OPMs). In the current article we propose a novel impedance-based yttrium-iron garnet (IM-YIG) magnetometer, offering a sensitivity of approximately 40 pT/√Hz and fast recovery time less than 1 ms, which is crucial for detection and analysis of rapidly decaying exponentials. By contrast with conventional (SQUID, OPM) sensors used for MRX, the proposed IM-YIG sensor operates at room temperature, maintains a wide dynamic range, and can be readily scaled to multichannel configurations, making it a promising alternative for advanced MRX applications, including characterization of magnetic particles. Unlike our previously reported optical YIG sensor, which relies on laser-based detection, the IM-YIG design eliminates laser components and thus simplifies the overall setup, improving its stability. We validated its performance through test tube experiments with magnetic micro- and nanoparticles, demonstrating stable detection of weak magnetic fields and fast decaying signals of relaxation time less than 20 ms. Overall, the IM-YIG magnetometer expands the toolkit for MRX by combining high sensitivity and fast recovery time with greater practicality and cost-effectiveness.